Electrochemical biosensor based on glucose oxidase-coupled cellulose membrane for continuous monitoring of α-amylase in flowing abdominal drainage fluids

Xiaohui Tang, Yan Cai, Zonghui Li, Min Zhang, Bingqing Liang, Xinyu Liu, Xiang Chen, Nan Shi, Sijia Xie, Chang Chen

Biosensors and Bioelectronics · 2026-07 · 304 · 118639

DOI: 10.1016/j.bios.2026.118639 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-07. Verfasst von Xiaohui Tang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Medical Chips, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Glucose Oxidase, alpha-Amylases. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Shanghai Jiao Tong University Medical School Affiliated Ruijin Hospital, Key Technologies Research and Development Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Despite the critical role of α-amylase assessment in diagnosing postoperative pancreatic fistula, conventional intermittent testing suffers from inherent delays, overburdened clinical laboratories, and color interference from pigmented drainage fluids. To address these limitations, we present an electrochemical biosensor enabling potential bedside continuous monitoring of α-amylase activity in abdominal drainage fluids from high-risk patients. The system integrates chronoamperometry with a glucose oxidase-functionalized cellulose fiber membrane, a carbon screen-printed electrode, and a microfluidic channel, facilitating continuous, color-immune detection in flowing clinical samples. The sensor exhibited a bilinear range of 100-10000 U/L with a detection limit of 34.7 U/L. To ensure reproducibility, single-point calibration and on-site reconstruction methods were employed to minimize batch-to-batch variability. Finally, preliminary validation using complex, dynamic-flow clinical drainage samples demonstrated reasonable agreement with hospital-reported values, indicating potential clinical utility, though larger cohort studies are warranted to fully establish accuracy and reliability. Overall, this proof-of-concept study demonstrates quantitative α-amylase detection in raw drainage fluid under dynamic flow conditions, representing a step toward continuous monitoring and clinical translation, pending further optimization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesGlucose Oxidasealpha-AmylasesHumansCelluloseEquipment DesignElectrochemical TechniquesLimit of DetectionReproducibility of ResultsMembranes, ArtificialEnzymes, Immobilized

Stichwörter der Autor:innen

Continuous monitoringDrainage fluid α-amylaseElectrochemical biosensorEnzyme cascadeFlow-injection analysisPostoperative pancreatic fistula

Substanzen

Glucose Oxidasealpha-AmylasesCelluloseMembranes, ArtificialEnzymes, Immobilized

Autor:innen und Institutionen

  • Institute of Medical Chips, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
  • Nursing Department, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
  • School of Microelectronics, Shanghai University, Shanghai, 201800, China.
  • Department of General Surgery, Pancreatic Disease Center, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
  • Emergency Department, Putuo Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, 200062, China. Electronic address: nanshi1227@shu.edu.cn.
  • Institute of Medical Chips, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China; School of Microelectronics, Shanghai University, Shanghai, 201800, China. Electronic address: sijia…

Förderung

  • National Key Research and Development Program of China
  • Shanghai Jiao Tong University Medical School Affiliated Ruijin Hospital
  • Key Technologies Research and Development Program
  • East China Normal University
  • Shanghai University of Traditional Chinese Medicine
  • School of Medicine, Shanghai Jiao Tong University
  • Shanghai University
  • Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences

Zitieren

APA

Tang, X., Cai, Y., Li, Z., Zhang, M., Liang, B., Liu, X., Chen, X., Shi, N., Xie, S., & Chen, C. (2026). Electrochemical biosensor based on glucose oxidase-coupled cellulose membrane for continuous monitoring of α-amylase in flowing abdominal drainage fluids. Biosensors and Bioelectronics, 304, 118639. https://doi.org/10.1016/j.bios.2026.118639

Vancouver

Tang X, Cai Y, Li Z, Zhang M, Liang B, Liu X, et al. Electrochemical biosensor based on glucose oxidase-coupled cellulose membrane for continuous monitoring of α-amylase in flowing abdominal drainage fluids. Biosensors and Bioelectronics. 2026;304:118639. doi:10.1016/j.bios.2026.118639

BibTeX
@article{Tang2026,
  author = {Tang, Xiaohui and Cai, Yan and Li, Zonghui and Zhang, Min and Liang, Bingqing and Liu, Xinyu and Chen, Xiang and Shi, Nan and Xie, Sijia and Chen, Chang},
  title = {Electrochemical biosensor based on glucose oxidase-coupled cellulose membrane for continuous monitoring of α-amylase in flowing abdominal drainage fluids},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {304},
  pages = {118639},
  doi = {10.1016/j.bios.2026.118639}
}