EUVIMEDEUVIMED entdecken
Crossref

Single tube cell-free transcription and autocatalytic signal amplification based fluorescent biosensor for microRNA detection

Qian Xie, Ming Chen, Zhenyu Lin

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.118626 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Qian Xie und 2 weiteren Autor:innen. Beteiligte Einrichtung: Ministry of Education Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection fo…. Hauptthemen laut MEDLINE: MicroRNAs, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: NSFC.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cell-free biosensing systems offer programmable, rapid, and low-cost molecular detection, which have been applied in nucleic acid assays frequently, but mostly rely on multiple enzymes and separate amplification steps which limit their application. In this study, using miRNA-21 as a model target, a single-tube, isothermal, cell-free biosensing platform that integrates SplintR ligase-mediated template assembly with T7 RNA polymerase-driven, product-assisted autocatalytic transcriptional cycling has been developed. The presence of target miRNA triggers the ligation of two DNA probes to form a functional transcription template, initiating the synthesis of light-up RNA aptamers through the cell-free system. The transcribed aptamer also re-enters the reaction as an RNA "splint", regenerating new templates and triggering additional transcription rounds, thereby establishing an autocatalytic signal amplification under constant conditions. The one-pot workflow does not require reverse transcription, thermocycling, or separate pre-amplification, minimizing hands-on steps and reducing contamination risk. The produced RNA aptamer can bind with a cognate fluorogenic dye to produce fluorescence signal and this can be used for target quantification. The platform achieves a detection limit of 0.52 pM with a linear range of 1 pM-1 μM, and demonstrates high specificity against closely related miRNA sequences. The proposed system was successfully applied to detect target in clinical serum samples, yielding satisfactory results. This work presents a rapid, sensitive, and easy-to-use strategy for miRNA quantification, offering a robust tool for point-of-care testing and liquid biopsy applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroRNAsBiosensing TechniquesHumansAptamers, NucleotideLimit of DetectionCell-Free SystemNucleic Acid Amplification TechniquesDNA-Directed RNA PolymerasesTranscription, GeneticSpectrometry, FluorescenceFluorescent DyesViral Proteins

Stichwörter der Autor:innen

Autocatalytic signal amplificationCell-free biosensing systemsClinical serum samplesSplintR ligasemiRNA-21

Substanzen

MicroRNAsAptamers, NucleotideMIRN21 microRNA, humanDNA-Directed RNA Polymerasesbacteriophage T7 RNA polymeraseFluorescent DyesViral Proteins

Autor:innen und Institutionen

  • Ministry of Education Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety and Healthy, College of Chemistry, Fuzhou University, Fu…

Förderung

  • NSFC

Zitieren

APA

Xie, Q., Chen, M., & Lin, Z. (2026). Single tube cell-free transcription and autocatalytic signal amplification based fluorescent biosensor for microRNA detection. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118626

Vancouver

Xie Q, Chen M, Lin Z. Single tube cell-free transcription and autocatalytic signal amplification based fluorescent biosensor for microRNA detection. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118626

BibTeX
@article{Xie2026,
  author = {Xie, Qian and Chen, Ming and Lin, Zhenyu},
  title = {Single tube cell-free transcription and autocatalytic signal amplification based fluorescent biosensor for microRNA detection},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.118626}
}
Kostenlos starten →