Artifact-free, colocalized opto-electrophysiology enabled by a flexible, multimodal interface integrating transparent MXene microelectrodes and microLEDs
Biosensors and Bioelectronics · 2026-07 · 304 · 118620
DOI: 10.1016/j.bios.2026.118620 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-07. Verfasst von Royce Dong und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA; Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal…. Hauptthemen laut MEDLINE: Optogenetics, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 77 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NEI NIH HHS, NINDS NIH HHS, Advanced Research and Invention Agency.
Abstract (Originalsprache)
Neurotechnologies capable of both modulating and recording neural activity are critical for investigating neural function and disease. Optoelectronic probes incorporating micro-light-emitting diodes (μLEDs) and transparent microelectrodes enable colocalized optogenetic stimulation and electrophysiological recordings with high spatiotemporal resolution but often suffer from stimulation artifacts. In this work, we present a thin, flexible, and conformal neural interface integrating blue μLEDs (460 nm) with transparent Ti3C2Tx MXene micro-electrocorticography (μECoG) electrodes for simultaneous, crosstalk-free optical stimulation and electrical recordings. Transparent Ti3C2Tx μECoG electrodes show an optical transmittance of 54.9 ± 0.9% at 460 nm and an impedance modulus of 291.9 ± 99.9 kΩ at 1 kHz. The μLEDs provide up to 86.1 ± 14.7 mW mm-2 with minimal tissue heating and negligible optical distortion through transparent Ti3C2Tx channels. We systematically investigate the mechanisms of the stimulation artifacts and present a methodological framework that is generalizable across multimodal neural interface materials and geometries. With this framework, we demonstrate that the Ti3C2Tx electrodes are minimally susceptible to photoelectric artifacts and that the remaining electromagnetic interference artifacts are minimized using transient μLED drive pulse shaping, ultimately achieving artifact-free, colocalized functionality. The novel multimodal interface is validated in an acute mouse model, establishing it as a powerful platform that enables bidirectional, crosstalk-free interrogation of neural circuits with high spatiotemporal precision.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA; Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA…
- Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, PA, USA; Center for Neuroengineering and Therapeutics, University of Pennsylvania,…
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA; Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA, USA.
- A. J. Drexel Nanomaterials Institute, and Department of Materials Science and Engineering, Drexel University, Philadelphia, PA, USA.
- Department of Neurology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA; Division of Neurology, Department of Pediatrics, The Children's Hospital of Philadelphia, Philadelphia, PA, USA.
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA; Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA, USA; Department of Neurology, Perelman School…
Förderung
- NEI NIH HHS
- NINDS NIH HHS
- Advanced Research and Invention Agency
- Foundation for the National Institutes of Health
- National Institutes of Health
- National Science Foundation
Zitieren
APA
Dong, R., Chen, Y., Garg, R., Averbeck, S. R., Wun, C., Unegbu, P., Shankar, S., Ahmad, S., Jung, J., Zahed, M. A., Zhang, D., Gogotsi, Y., Takano, H., Litt, B., & Vitale, F. (2026). Artifact-free, colocalized opto-electrophysiology enabled by a flexible, multimodal interface integrating transparent MXene microelectrodes and microLEDs. Biosensors and Bioelectronics, 304, 118620. https://doi.org/10.1016/j.bios.2026.118620
Vancouver
Dong R, Chen Y, Garg R, Averbeck SR, Wun C, Unegbu P, et al. Artifact-free, colocalized opto-electrophysiology enabled by a flexible, multimodal interface integrating transparent MXene microelectrodes and microLEDs. Biosensors and Bioelectronics. 2026;304:118620. doi:10.1016/j.bios.2026.118620
BibTeX
@article{Dong2026,
author = {Dong, Royce and Chen, Yuzhang and Garg, Raghav and Averbeck, Spencer R and Wun, Chris and Unegbu, Placid and Shankar, Sneha and Ahmad, Shereen and Jung, Jimin and Zahed, Md Abu and Zhang, Danzhen and Gogotsi, Yury and Takano, Hajime and Litt, Brian and Vitale, Flavia},
title = {Artifact-free, colocalized opto-electrophysiology enabled by a flexible, multimodal interface integrating transparent MXene microelectrodes and microLEDs},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {304},
pages = {118620},
doi = {10.1016/j.bios.2026.118620}
}
EUVIMED