EUVIMEDEUVIMED entdecken
Crossref

Rapid self-assembly and signal amplification based on photoactive Z907 for detecting colorectal cancer biomarker vascular endothelial growth factor

Hung-Yu Lin, Hao-Tsai Cheng, Nai-Chuan Chen, Tsung-Hsing Chen, Mu-Yi Hua

Biosensors and Bioelectronics · 2026-07 · 303 · 118594

DOI: 10.1016/j.bios.2026.118594 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-07. Verfasst von Hung-Yu Lin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical and Materials Engineering, Chang Gung University, Taoyuan, 333323, Taiwan. Hauptthemen laut MEDLINE: Vascular Endothelial Growth Factor A, Colorectal Neoplasms, Biosensing Techniques, Biomarkers, Tumor. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Linkou Chang Gung Memorial Hospital, Chang Gung Memorial Hospital, Northeastern State University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper introduces a continuous transient photoelectrochemical (PEC) biosensing strategy for rapid anti-vascular endothelial growth factor (VEGF) immobilization and quantification of VEGF in serum for colorectal cancer (CRC) diagnosis. A gold electrode modified with cis-bis(isothiocyanato) (2,2'-bipyridyl-4,4'-dicarboxylato) (4,4'-di-nonyl-2'-bipyridyl)ruthenium (II) (Z907) (Au/Z907) was used. By optimizing the electrolyte composition and applied potential under continuous high-frequency light switching, stable transient photocurrent bands were produced, enabling real-time sensing with intrinsic signal amplification and improved precision. Under optimized conditions (1 mM phosphate-buffered saline, 0.15 V bias, 25 W white-light illumination, and 2 Hz modulation for 4 min), anti-VEGF antibodies were rapidly immobilized on the Au/Z907 electrode. After blocking nonspecific binding sites with bovine serum albumin, the biosensor was used to quantify serum VEGF in clinical samples obtained in Taiwan from healthy donors (n = 11) and patients with tubular adenoma (n = 12), serrated adenoma (n = 11), untreated CRC (n = 11), and treated CRC (n = 3). Comparison with a commercial enzyme-linked immunosorbent assay kit revealed no significant differences among the five groups (p > 0.05, Student's t-test), validating the accuracy of the proposed platform. Receiver operating characteristic analysis further demonstrated excellent diagnostic performance. Overall, this work presents a cost-effective and instrumentation-light PEC biosensing platform capable of rapid antibody immobilization, calibration, and serum analysis on a single electrode, with potential applications in point-of-care testing in community hospitals and resource-limited settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vascular Endothelial Growth Factor AColorectal NeoplasmsBiosensing TechniquesBiomarkers, TumorHumansElectrochemical TechniquesGoldAntibodies, ImmobilizedLimit of DetectionEquipment Design

Stichwörter der Autor:innen

Photoelectrochemical biosensingReal-time quantificationSignal amplificationVascular endothelial growth factorZ907

Substanzen

Vascular Endothelial Growth Factor ABiomarkers, TumorGoldVEGFA protein, humanAntibodies, Immobilized

Autor:innen und Institutionen

  • Department of Chemical and Materials Engineering, Chang Gung University, Taoyuan, 333323, Taiwan.
  • Division of Gastroenterology and Hepatology, Department of Internal Medicine, New Taipei Municipal Tucheng Hospital (Built and Operated by Chang Gung Medical Foundation), New Taipei City, 236017, Taiwan; Department of G…
  • Department of Electronics Engineering, Chang Gung University, Taoyuan, 333323, Taiwan.
  • Department of Gastroenterology, Linkou Chang Gung Memorial Hospital, Taoyuan, 333423, Taiwan; College of Medicine, Chang Gung University, Taoyuan, 333323, Taiwan.
  • Department of Chemical and Materials Engineering, Chang Gung University, Taoyuan, 333323, Taiwan; Department of Gastroenterology, Linkou Chang Gung Memorial Hospital, Taoyuan, 333423, Taiwan. Electronic address: huamy@m…

Förderung

  • Linkou Chang Gung Memorial Hospital
  • Chang Gung Memorial Hospital
  • Northeastern State University
  • National Science and Technology Council

Zitieren

APA

Lin, H. Y., Cheng, H. T., Chen, N. C., Chen, T. H., & Hua, M. Y. (2026). Rapid self-assembly and signal amplification based on photoactive Z907 for detecting colorectal cancer biomarker vascular endothelial growth factor. Biosensors and Bioelectronics, 303, 118594. https://doi.org/10.1016/j.bios.2026.118594

Vancouver

Lin HY, Cheng HT, Chen NC, Chen TH, Hua MY. Rapid self-assembly and signal amplification based on photoactive Z907 for detecting colorectal cancer biomarker vascular endothelial growth factor. Biosensors and Bioelectronics. 2026;303:118594. doi:10.1016/j.bios.2026.118594

BibTeX
@article{Lin2026,
  author = {Lin, Hung-Yu and Cheng, Hao-Tsai and Chen, Nai-Chuan and Chen, Tsung-Hsing and Hua, Mu-Yi},
  title = {Rapid self-assembly and signal amplification based on photoactive Z907 for detecting colorectal cancer biomarker vascular endothelial growth factor},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {303},
  pages = {118594},
  doi = {10.1016/j.bios.2026.118594}
}
Kostenlos starten →