Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-07. Verfasst von Chaeeun Kim und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Kor…. Hauptthemen laut MEDLINE: Graphite, Biosensing Techniques, Potassium, Pyruvate Kinase. Die Arbeit nennt 38 Literaturangaben. Gefördert von: Ministry of Health and Welfare, Korea Ministry of Science and ICT.
Abstract (Originalsprache)
Potassium (K+) monitoring is essential for clinical management, particularly for point-of-care testing (POCT) that requires rapid and reliable analysis. Conventional potentiometric ion-selective electrodes rely on equilibrium potential responses and frequent calibration, which limits their applicability in decentralized testing. Here, we present an amperometric K+ biosensor based on a pyruvate kinase/oxidase (PK/POx) enzyme cascade integrated with a laser-induced graphene (LIG) electrode. K+-dependent enzymatic activity is converted into a direct current signal via 4-nitrosoaniline-mediated redox cycling. The porous, defect-rich LIG architecture acts as a reaction-accelerating electrochemical interface that facilitates enzymatic turnover and mediator-assisted electron transfer. Under optimized conditions, the sensor exhibited a linear response over the physiological range of 2-8 mM, a detection limit of 1.56 mM, high selectivity against interfering ions, excellent inter-sensor reproducibility (RSD = 2.41-5.20%), and reliable performance in spiked human serum samples. By operating in a rate-governed, current-mode sensing framework rather than an equilibrium-based potential measurement, the PK/POx/LIG platform enables point-of-use operation without requiring sensor-specific or user-performed calibration at the time of measurement, enabling rapid potassium monitoring in POCT applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea.
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul, 08826, Republic of Korea; THEDONEE Inc., Research Center, Seoul, Republic of Korea. Electron…
Förderung
- Ministry of Health and Welfare
- Korea Ministry of Science and ICT
Zitieren
APA
Kim, C., Kim, C., Kim, Y., & Lee, K. (2026). Calibration-free potassium quantification via a stoichiometric enzyme cascade on laser-induced graphene. Biosensors and Bioelectronics, 304, 118572. https://doi.org/10.1016/j.bios.2026.118572
Vancouver
Kim C, Kim C, Kim Y, Lee K. Calibration-free potassium quantification via a stoichiometric enzyme cascade on laser-induced graphene. Biosensors and Bioelectronics. 2026;304:118572. doi:10.1016/j.bios.2026.118572
BibTeX
@article{Kim2026,
author = {Kim, Chaeeun and Kim, Chaehyung and Kim, Yujoon and Lee, Kangwon},
title = {Calibration-free potassium quantification via a stoichiometric enzyme cascade on laser-induced graphene},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {304},
pages = {118572},
doi = {10.1016/j.bios.2026.118572}
}
EUVIMED