Attogram per milliliter detection of prostate cancer biomarker using polymer dots-based electrolyte-gated organic field-effect transistor
Biosensors and Bioelectronics · 2026-06 · 301 · 118476
DOI: 10.1016/j.bios.2026.118476 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-06. Verfasst von Samira Mansouri Majd und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Semiconductors, Materials and Energy Research Center (MERC), P.O. Box, Karaj, 31787-316, Iran. Electronic address: Samiramansouri16@yah…. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Prostate-Specific Antigen, Biosensing Techniques, Polymers. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 63 Literaturangaben. Gefördert von: Razi University.
Abstract (Originalsprache)
Early detection of biomarkers in body fluids plays a critical role in the diagnosis and prognosis of prostate cancer, the second most common cancer in men. In this study, we synthesized novel semiconducting polymer dots (Pdots) to serve as the channel material in electrolyte-gated organic field-effect transistors (EGOFET) for the ultrasensitive detection of PSA antigen, a key cancer biomarker. To fabricate the active channel material, Pdots were drop-cast onto the FET surface, and the surface was subsequently functionalized with PSA antibodies. The Pdot EGOFET immunosensor demonstrated the ability to detect PSA antigen across a concentration range of 10 ag/mL to 10 ng/mL, with a significant decrease in drain current (Ids) and a high sensitivity of 0.9097 μA/decade. The sensor exhibited a limit of detection (LOD) of 3.0 ag/mL. Furthermore, the Pdot EGOFET immunosensor displayed remarkable electrical characteristics, including a mobility of 0.029 cm2V-1s-1, an on/off current ratio of 22.66, and a subthreshold swing (SS) of 909.1 mV/decade. Additionally, the sensor demonstrated excellent selectivity, with its performance being compared favorably to an enzyme-linked immunosorbent assay (ELISA) for detecting PSA in spiked human serum samples. The positive and promising results of this study indicate that the developed Pdot EGOFET immunosensor holds significant potential as a highly effective platform for cancer diagnosis and therapeutic monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Semiconductors, Materials and Energy Research Center (MERC), P.O. Box, Karaj, 31787-316, Iran. Electronic address: Samiramansouri16@yahoo.com.
- Department of Chemistry, Razi University, Kermanshah, 67149-67346, Iran.
- Department of Chemistry, Razi University, Kermanshah, 67149-67346, Iran. Electronic address: mshamsipur@yahoo.com.
Förderung
- Razi University
Zitieren
APA
Mansouri Majd, S., Mirzapour, F., Shamsipur, M., & Nematifar, Z. (2026). Attogram per milliliter detection of prostate cancer biomarker using polymer dots-based electrolyte-gated organic field-effect transistor. Biosensors and Bioelectronics, 301, 118476. https://doi.org/10.1016/j.bios.2026.118476
Vancouver
Mansouri Majd S, Mirzapour F, Shamsipur M, Nematifar Z. Attogram per milliliter detection of prostate cancer biomarker using polymer dots-based electrolyte-gated organic field-effect transistor. Biosensors and Bioelectronics. 2026;301:118476. doi:10.1016/j.bios.2026.118476
BibTeX
@article{MansouriMajd2026,
author = {Mansouri Majd, Samira and Mirzapour, Fatemeh and Shamsipur, Mojtaba and Nematifar, Ziba},
title = {Attogram per milliliter detection of prostate cancer biomarker using polymer dots-based electrolyte-gated organic field-effect transistor},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {301},
pages = {118476},
doi = {10.1016/j.bios.2026.118476}
}