EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

HF-Sensor: A non-invasive biosensor system for heart failure diagnosis and monitoring at the point-of-care

Miguel A D Neves, Andrea Cruz, Pedro Melo, Evelyn Santos, Francisco Vasques-Nóvoa, Ana Beatriz Baptista, João Barbosa-Breda, Fernando Friões, Jorge Almeida, João Pedro Ferreira, Adelino Leite-Moreira, Amândio Rocha-Sousa und 1 weitere

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.118427 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Miguel A D Neves und 12 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Research and Innovation in Health (i3S), University of Porto, Porto, 4200-135, Portugal; Molecular and Analytical Medicine Laboratory, …. Hauptthemen laut MEDLINE: Heart Failure, Biosensing Techniques, Natriuretic Peptide, Brain, Point-of-Care Systems. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon Europe, 'la Caixa' Foundation, Foundation for Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Heart failure (HF) is a major public health challenge, contributing to high morbidity, mortality, and significant economic burden worldwide. Early diagnosis and accurate risk stratification are critical for improving patient outcomes and guiding clinical decisions. N-terminal pro-B-type natriuretic peptide (NT-proBNP) is a well-established blood biomarker of ventricular overload, widely used for diagnosing HF and assessing its severity. Beyond diagnosis, NT-proBNP provides valuable prognostic insights into treatment response and can predict adverse cardiovascular events, such as HF-related hospitalizations and mortality, thus playing a key role in personalized care and therapeutic management. Despite its clinical significance, current CE/FDA-certified methods for NT-proBNP measurement face critical limitations, particularly in point-of-care settings and for ongoing, minimally or non-invasive monitoring. These constraints hinder the ability to perform remote (e.g. community medical clinic) monitoring-a crucial capability for revolutionizing heart failure management. To address this challenge, we report the development and proof-of-concept validation of an ultrasensitive (compared to gold standard enzyme-linked immunosorbent assays), miniaturized electrochemical biosensor for fast and minute sample detection of NT-proBNP in tears from a well-characterized cohort of heart failure patients. Correlation analysis of NT-proBNP concentrations in tear fluid and blood plasma/serum, together with key clinical parameters, demonstrates that tear fluid is a promising non-invasive matrix for heart failure diagnosis and continuous monitoring in point-of-care settings. This approach provides a transformative pathway to advance heart failure management by enabling remote, point-of-care diagnostic monitoring outside of centralized hospitals and laboratories.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart FailureBiosensing TechniquesNatriuretic Peptide, BrainPoint-of-Care SystemsPeptide FragmentsHumansBiomarkersEquipment DesignRapid Diagnostic Tests

Substanzen

Natriuretic Peptide, Brainpro-brain natriuretic peptide (1-76)Peptide FragmentsBiomarkers

Autor:innen und Institutionen

  • Institute for Research and Innovation in Health (i3S), University of Porto, Porto, 4200-135, Portugal; Molecular and Analytical Medicine Laboratory, Department of Biomedicine, Faculty of Medicine, University of Porto, P…
  • International Iberian Nanotechnology Laboratory (INL), Braga, 4715-330, Portugal.
  • RISE-Health, Department of Surgery and Physiology, Faculty of Medicine, University of Porto, Porto, 4200-319, Portugal; Department of Internal Medicine, Unidade Local de Saúde São João, Porto, 4200-319, Portugal.
  • RISE-Health, Department of Surgery and Physiology, Faculty of Medicine, University of Porto, Porto, 4200-319, Portugal.
  • Department of Internal Medicine, Unidade Local de Saúde São João, Porto, 4200-319, Portugal.
  • RISE-Health, Department of Surgery and Physiology, Faculty of Medicine, University of Porto, Porto, 4200-319, Portugal; Department of Internal Medicine, Unidade Local de Saúde São João, Porto, 4200-319, Portugal; Univer…

Förderung

  • Horizon Europe
  • 'la Caixa' Foundation
  • Foundation for Science and Technology
  • European Health and Digital Executive Agency
  • European Commission

Zitieren

APA

Neves, M. A. D., Cruz, A., Melo, P., Santos, E., Vasques-Nóvoa, F., Baptista, A. B., Barbosa-Breda, J., Friões, F., Almeida, J., Ferreira, J. P., Leite-Moreira, A., Rocha-Sousa, A., & Mendes Pinto, I. (2026). HF-Sensor: A non-invasive biosensor system for heart failure diagnosis and monitoring at the point-of-care. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118427

Vancouver

Neves MAD, Cruz A, Melo P, Santos E, Vasques-Nóvoa F, Baptista AB, et al. HF-Sensor: A non-invasive biosensor system for heart failure diagnosis and monitoring at the point-of-care. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118427

BibTeX
@article{Neves2026,
  author = {Neves, Miguel A D and Cruz, Andrea and Melo, Pedro and Santos, Evelyn and Vasques-Nóvoa, Francisco and Baptista, Ana Beatriz and Barbosa-Breda, João and Friões, Fernando and Almeida, Jorge and Ferreira, João Pedro and Leite-Moreira, Adelino and Rocha-Sousa, Amândio and Mendes Pinto, Inês},
  title = {HF-Sensor: A non-invasive biosensor system for heart failure diagnosis and monitoring at the point-of-care},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.118427}
}
Kostenlos starten →