RPA-CRISPR/Cas12a-coupled microfluidic biosensor enabling on-site, sensitive quantification of Vibrio parahaemolyticus
Biosensors and Bioelectronics · 2026-03 · 296 · 118327
DOI: 10.1016/j.bios.2025.118327 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-03. Verfasst von Jiehong Fang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang Uni…. Hauptthemen laut MEDLINE: Vibrio parahaemolyticus, Biosensing Techniques, Nucleic Acid Amplification Techniques, CRISPR-Cas Systems. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Shenzhen Science and Technology Innovation Program, Zhejiang Province Natural Science Foundation, National Natural Science Foundation of China.
Abstract (Originalsprache)
Vibrio parahaemolyticus is a major cause of seafood-associated gastroenteritis and aquatic animal diseases, posing persistent threats to public health and aquaculture. Rapid and accurate on-site quantitative detection is essential for risk assessment and early intervention. Although qPCR and digital PCR provide reliable quantification, their reliance on complex instrumentation limits field deployment. RPA-CRISPR-based isothermal assays offer a low-equipment alternative; however, existing approaches lack robust methodological strategies to achieve standard-curve-based quantitative reliability under field-deployable conditions. Here, we propose a methodological framework that enables in-run calibration and variance control for quantitative isothermal amplification by integrating reaction-volume locking and simultaneous standard-curve generation, implemented here within a closed centrifugal microfluidic system. A multi-unit microfluidic platform preloaded with gradient concentration standard plasmids allows concurrent construction of standard curves and sample analysis in a single run, reducing the impact of environmental and batch-to-batch variability. Signal generation was achieved using a one-pot RPA-CRISPR/Cas12a assay, in which balanced amplification and cleavage kinetics were obtained by screening crRNAs targeting suboptimal PAM sites and optimizing reaction conditions. The platform achieved a detection limit of 6.08 copies/μL and a linear quantitative range of 100-104 copies/μL (R2 > 0.96), with performance comparable to qPCR (AUC = 0.984), and acceptable intra- and inter-assay variability under the tested conditions, with relative standard deviations of 2.63-6.07 %, at a cost of approximately $3.30 per test. Validation using spiked and real seafood samples demonstrated reliable on-site quantification. This work establishes a transferable quantitative methodology for RPA-CRISPR-based isothermal assays, advancing field-deployable pathogen detection in aquaculture and food safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang University, Hangzhou, Zhejiang, 310018, China.
- Zhejiang Gongzheng Testing Center Co., Ltd, Hangzhou, Zhejiang, 311305, China.
- Zhejiang Zanyu Technology Group Co., Ltd, Hangzhou, Zhejiang, 310012, China.
- Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang University, Hangzhou, Zhejiang, 310018, China. Electronic address: chenze…
- Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang University, Hangzhou, Zhejiang, 310018, China. Electronic address: jiangh…
Förderung
- Shenzhen Science and Technology Innovation Program
- Zhejiang Province Natural Science Foundation
- National Natural Science Foundation of China
- Basic and Applied Basic Research Foundation of Guangdong Province
- Fundamental Research Funds for the Provincial Universities of Zhejiang
Zitieren
APA
Fang, J., Chen, Q., Ran, M., Chen, R., Chen, W., Cui, J., Wang, J., Zhong, K., Shi, L., Lu, C., & Jiang, H. (2026). RPA-CRISPR/Cas12a-coupled microfluidic biosensor enabling on-site, sensitive quantification of Vibrio parahaemolyticus. Biosensors and Bioelectronics, 296, 118327. https://doi.org/10.1016/j.bios.2025.118327
Vancouver
Fang J, Chen Q, Ran M, Chen R, Chen W, Cui J, et al. RPA-CRISPR/Cas12a-coupled microfluidic biosensor enabling on-site, sensitive quantification of Vibrio parahaemolyticus. Biosensors and Bioelectronics. 2026;296:118327. doi:10.1016/j.bios.2025.118327
BibTeX
@article{Fang2026,
author = {Fang, Jiehong and Chen, Qi and Ran, Meijuan and Chen, Ran and Chen, Wenyu and Cui, Jing and Wang, Jing and Zhong, Kai and Shi, Liwen and Lu, Chenze and Jiang, Han},
title = {RPA-CRISPR/Cas12a-coupled microfluidic biosensor enabling on-site, sensitive quantification of Vibrio parahaemolyticus},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {296},
pages = {118327},
doi = {10.1016/j.bios.2025.118327}
}
EUVIMED