EUVIMEDEUVIMED entdecken
Crossref

RPA-CRISPR/Cas12a-coupled microfluidic biosensor enabling on-site, sensitive quantification of Vibrio parahaemolyticus

Jiehong Fang, Qi Chen, Meijuan Ran, Ran Chen, Wenyu Chen, Jing Cui, Jing Wang, Kai Zhong, Liwen Shi, Chenze Lu, Han Jiang

Biosensors and Bioelectronics · 2026-03 · 296 · 118327

DOI: 10.1016/j.bios.2025.118327 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-03. Verfasst von Jiehong Fang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang Uni…. Hauptthemen laut MEDLINE: Vibrio parahaemolyticus, Biosensing Techniques, Nucleic Acid Amplification Techniques, CRISPR-Cas Systems. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Shenzhen Science and Technology Innovation Program, Zhejiang Province Natural Science Foundation, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Vibrio parahaemolyticus is a major cause of seafood-associated gastroenteritis and aquatic animal diseases, posing persistent threats to public health and aquaculture. Rapid and accurate on-site quantitative detection is essential for risk assessment and early intervention. Although qPCR and digital PCR provide reliable quantification, their reliance on complex instrumentation limits field deployment. RPA-CRISPR-based isothermal assays offer a low-equipment alternative; however, existing approaches lack robust methodological strategies to achieve standard-curve-based quantitative reliability under field-deployable conditions. Here, we propose a methodological framework that enables in-run calibration and variance control for quantitative isothermal amplification by integrating reaction-volume locking and simultaneous standard-curve generation, implemented here within a closed centrifugal microfluidic system. A multi-unit microfluidic platform preloaded with gradient concentration standard plasmids allows concurrent construction of standard curves and sample analysis in a single run, reducing the impact of environmental and batch-to-batch variability. Signal generation was achieved using a one-pot RPA-CRISPR/Cas12a assay, in which balanced amplification and cleavage kinetics were obtained by screening crRNAs targeting suboptimal PAM sites and optimizing reaction conditions. The platform achieved a detection limit of 6.08 copies/μL and a linear quantitative range of 100-104 copies/μL (R2 > 0.96), with performance comparable to qPCR (AUC = 0.984), and acceptable intra- and inter-assay variability under the tested conditions, with relative standard deviations of 2.63-6.07 %, at a cost of approximately $3.30 per test. Validation using spiked and real seafood samples demonstrated reliable on-site quantification. This work establishes a transferable quantitative methodology for RPA-CRISPR-based isothermal assays, advancing field-deployable pathogen detection in aquaculture and food safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vibrio parahaemolyticusBiosensing TechniquesNucleic Acid Amplification TechniquesCRISPR-Cas SystemsVibrio InfectionsLimit of DetectionAnimalsSeafoodLab-On-A-Chip DevicesEquipment Design

Stichwörter der Autor:innen

In-run calibrationMicrofluidic biosensingQuantitative isothermal amplificationRPA-CRISPR/Cas12aVibrio parahaemolyticus

Autor:innen und Institutionen

  • Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang University, Hangzhou, Zhejiang, 310018, China.
  • Zhejiang Gongzheng Testing Center Co., Ltd, Hangzhou, Zhejiang, 311305, China.
  • Zhejiang Zanyu Technology Group Co., Ltd, Hangzhou, Zhejiang, 310012, China.
  • Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang University, Hangzhou, Zhejiang, 310018, China. Electronic address: chenze…
  • Key Laboratory of Specialty Agri-products Quality and Hazard Controlling Technology of Zhejiang Province, College of Life Sciences, China Jiliang University, Hangzhou, Zhejiang, 310018, China. Electronic address: jiangh…

Förderung

  • Shenzhen Science and Technology Innovation Program
  • Zhejiang Province Natural Science Foundation
  • National Natural Science Foundation of China
  • Basic and Applied Basic Research Foundation of Guangdong Province
  • Fundamental Research Funds for the Provincial Universities of Zhejiang

Zitieren

APA

Fang, J., Chen, Q., Ran, M., Chen, R., Chen, W., Cui, J., Wang, J., Zhong, K., Shi, L., Lu, C., & Jiang, H. (2026). RPA-CRISPR/Cas12a-coupled microfluidic biosensor enabling on-site, sensitive quantification of Vibrio parahaemolyticus. Biosensors and Bioelectronics, 296, 118327. https://doi.org/10.1016/j.bios.2025.118327

Vancouver

Fang J, Chen Q, Ran M, Chen R, Chen W, Cui J, et al. RPA-CRISPR/Cas12a-coupled microfluidic biosensor enabling on-site, sensitive quantification of Vibrio parahaemolyticus. Biosensors and Bioelectronics. 2026;296:118327. doi:10.1016/j.bios.2025.118327

BibTeX
@article{Fang2026,
  author = {Fang, Jiehong and Chen, Qi and Ran, Meijuan and Chen, Ran and Chen, Wenyu and Cui, Jing and Wang, Jing and Zhong, Kai and Shi, Liwen and Lu, Chenze and Jiang, Han},
  title = {RPA-CRISPR/Cas12a-coupled microfluidic biosensor enabling on-site, sensitive quantification of Vibrio parahaemolyticus},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {296},
  pages = {118327},
  doi = {10.1016/j.bios.2025.118327}
}
Kostenlos starten →