Electrochemical immunosensor for sensitive detection of Crimean–Congo hemorrhagic fever virus based on a flexible electrode of carbon nanofibers modified with copper (II) phosphate nanoflowers
Biosensors and Bioelectronics · 2026
DOI: 10.1016/j.bios.2025.118291 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Zeinab Rahmati und 1 weiteren Autor:innen. Beteiligte Einrichtung: Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran. Hauptthemen laut MEDLINE: Biosensing Techniques, Electrochemical Techniques, Hemorrhagic Fever Virus, Crimean-Congo, Nanofibers. Die Arbeit nennt 41 Literaturangaben. Gefördert von: National Foundation of Elites, Iran National Elites Foundation.
Abstract (Originalsprache)
Crimean-Congo hemorrhagic fever (CCHF) is an acute viral zoonosis and is transmitted through the bite of infected ticks, contact with tissue or blood of infected animals, or secretions of infected individuals. Due to its high mortality rate, no availability of effective treatment or vaccine, and high potential for spread, CCHF poses a serious threat to human health. In response to the need to develop rapid and low-cost detection methods, especially in underserved areas, a sensitive electrochemical immunosensor was designed and evaluated for Crimean-Congo hemorrhagic fever virus (CCHFV) detection. This biosensor was fabricated based on carbon nanofibers (CNFs) modified with copper (II) phosphate nanoflowers (Cu3(PO4)2 NFs), which were used as a flexible and conductive platform to immobilize the desired virus antibody for the design of the proposed electrochemical immunosensor. The cathodic peak current of Cu3(PO4)2 NFs in square wave voltammetry (SWV) was used as an analytical signal for the detection and measurement of the virus on the surface of this immunosensor. The results showed that this immunosensor is capable of detecting the virus in the concentration range of 1.00 × 10 to 1.00 × 108 PFU/mL with a limit of detection (LOD) of 3.30 PFU/mL. This system has features such as a wide linear range, high sensitivity, desirable stability and good reproducibility, that its efficiency was also confirmed in spiked human serum samples. This sensor holds promise for the development of portable tools for rapid detection of CCHFV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran.
- Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran. Electronic address: j.raoof@umz.ac.ir.
Förderung
- National Foundation of Elites
- Iran National Elites Foundation
Zitieren
APA
Rahmati, Z., & Raoof, J. B. (2026). Electrochemical immunosensor for sensitive detection of Crimean–Congo hemorrhagic fever virus based on a flexible electrode of carbon nanofibers modified with copper (II) phosphate nanoflowers. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.118291
Vancouver
Rahmati Z, Raoof JB. Electrochemical immunosensor for sensitive detection of Crimean–Congo hemorrhagic fever virus based on a flexible electrode of carbon nanofibers modified with copper (II) phosphate nanoflowers. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2025.118291
BibTeX
@article{Rahmati2026,
author = {Rahmati, Zeinab and Raoof, Jahan Bakhsh},
title = {Electrochemical immunosensor for sensitive detection of Crimean–Congo hemorrhagic fever virus based on a flexible electrode of carbon nanofibers modified with copper (II) phosphate nanoflowers},
journal = {Biosensors and Bioelectronics},
year = {2026},
doi = {10.1016/j.bios.2025.118291}
}
EUVIMED