Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Luca Guagneli und 5 weiteren Autor:innen. Beteiligte Einrichtung: GlucoModicum Ltd, Toinen linja 7, 00530, Helsinki, Finland. Hauptthemen laut MEDLINE: Biosensing Techniques, Ferrocyanides, Glucose, Electrochemical Techniques. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Enzymatic electrochemical biosensors are a cornerstone technology in enabling further advancements in the field of Continuous Glucose Monitoring (CGM). Pulsed amperometric methods improve the sensitivity and accuracy of electrochemical biosensors. The literature shows that pulsed amperometry increases the sensitivity of enzymatic glucose biosensors based on Prussian Blue (PB). However, the underlying mechanism responsible for this improvement is poorly understood, which impedes further development of this promising measurement method. The present work elucidates the role of the spontaneous reaction between hydrogen peroxide (H2O2) and Prussian White (PW) in the sensitivity improvement observed with pulsed amperometry. A charged working electrode (WE) containing PW can catalyze the H2O2 reduction in the open-circuit regime (OCP). The consumption of H2O2 over a 30-min contact at OCP was 65 % at a PW WE, compared to 13 % at a PB WE. This spontaneous process is associated with a partial discharge of the WE (PW → PB) between the amperometric pulses. The subsequent re-charging (PB → PW) yields the current amplification observed with pulsed amperometry. Based on this consideration, we developed and validated a model for glucose quantification using pulsed amperometry that considers the spontaneous reaction of H2O2 with PW. The model achieves 0.998 determination coefficient between glucose concentration and four analytical signals. The insights presented in this work support the optimization and development of the pulsed amperometric detection method in enzymatic glucose biosensors. Additionally, this work advances the understanding of H2O2 detection at PB-based sensors, and contributes to the development of precise and accurate enzymatic glucose biosensors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesFerrocyanidesGlucoseElectrochemical TechniquesBlood GlucoseHydrogen PeroxideGlucose OxidaseHumansEquipment DesignElectrodes

Stichwörter der Autor:innen

Continuous glucose monitoringGlucose biosensorHydrogen peroxide detectionPrussian BluePulsed amperometryWearable glucose biosensor

Substanzen

Ferrocyanidesferric ferrocyanideHydrogen PeroxideGlucoseGlucose OxidaseBlood Glucose

Autor:innen und Institutionen

  • GlucoModicum Ltd, Toinen linja 7, 00530, Helsinki, Finland.
  • GlucoModicum Ltd, Toinen linja 7, 00530, Helsinki, Finland; Åbo Akademi University, Faculty of Science and Engineering, Johan Gadolin Process Chemistry Centre, Laboratory of Molecular Science and Engineering, Henriksgat…

Zitieren

APA

Guagneli, L., Supala, E., Palomäki, T., Pérez, A. G., Hæggström, E., & Bobacka, J. (2026). Use of Prussian Blue pseudocapacitive properties to amplify the pulsed amperometric readout of biosensors. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.118283

Vancouver

Guagneli L, Supala E, Palomäki T, Pérez AG, Hæggström E, Bobacka J. Use of Prussian Blue pseudocapacitive properties to amplify the pulsed amperometric readout of biosensors. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2025.118283

BibTeX
@article{Guagneli2026,
  author = {Guagneli, Luca and Supala, Eszter and Palomäki, Tommi and Pérez, Alejandro García and Hæggström, Edward and Bobacka, Johan},
  title = {Use of Prussian Blue pseudocapacitive properties to amplify the pulsed amperometric readout of biosensors},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2025.118283}
}
Kostenlos starten →