EUVIMEDEUVIMED entdecken
Crossref

Target-inhibited MCOF-Apt@Ag self-assembly for multi-modal biosensor for detecting Vibrio parahaemolyticus

Jingyi Xiao, Tongtong Li, Jianing Sun, Xue Gao

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2025.118248 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Jingyi Xiao und 3 weiteren Autor:innen. Beteiligte Einrichtung: College of Food Science and Technology, Bohai University. National & Local Joint Engineering Research Center of Storage, Processing and Safety Contro…. Hauptthemen laut MEDLINE: Biosensing Techniques, Aptamers, Nucleotide, Vibrio parahaemolyticus, Metal-Organic Frameworks. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study proposed a colorimetric/fluorescence/SERS multi-modal biosensor based on aptamer-modified silver nanozymes (Ag@Apt) and magnetic covalent organic frameworks (MCOF) for the detection of V. parahaemolyticus. MCOF-Apt@Ag could catalyze the oxidation of the aggregation-induced emission luminogen tetra-(4-aminophenyl) ethylene (TPE-4A) to produce green TPE-4A2+. With the increase of V. parahaemolyticus, Ag@Apt preferentially bound to the bacteria, and the production of MCOF-Apt@Ag was suppressed, leading to a reduction in the enzymatic activity of the sensing system. TPE-4A2+ generated via catalytic oxidation decreased, leading to a color change of the system from dark green to light green. The UV-vis absorption at 600 nm decreased, while the fluorescence peak intensity of TPE-4A at 500 nm increased, thereby enabling both colorimetric and fluorescence detection. Additionally, silver nanozymes (Ag NPs) serve as SERS substrates and 4-mercaptobenzoic acid (4-MBA) acts as a SERS signal molecule. As the concentration of V. parahaemolyticus increased, the concentration of the Ag@Apt in the system also increased resulting in enhanced SERS signals from the biosensor. The lowest detection limits for colorimetric, fluorescence and SERS modes were 1.50 CFU/mL, 1.02 CFU/mL, and 0.97 CFU/mL. Multi-modal biosensors can provide stable multi-readout signals to ensure high detection sensitivity and accuracy, and a variety of quantitative modes with different detection capabilities can also improve the sensing performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesAptamers, NucleotideVibrio parahaemolyticusMetal-Organic FrameworksSilverColorimetryLimit of DetectionMetal Nanoparticles

Stichwörter der Autor:innen

Ag NPsAptamerMCOFMulti-modal biosensorVibrio parahaemolyticus

Substanzen

SilverAptamers, NucleotideMetal-Organic Frameworks

Autor:innen und Institutionen

  • College of Food Science and Technology, Bohai University. National & Local Joint Engineering Research Center of Storage, Processing and Safety Control Technology for Fresh Agricultural and Aquatic Products. Food Safety…

Zitieren

APA

Xiao, J., Li, T., Sun, J., & Gao, X. (2026). Target-inhibited MCOF-Apt@Ag self-assembly for multi-modal biosensor for detecting Vibrio parahaemolyticus. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.118248

Vancouver

Xiao J, Li T, Sun J, Gao X. Target-inhibited MCOF-Apt@Ag self-assembly for multi-modal biosensor for detecting Vibrio parahaemolyticus. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2025.118248

BibTeX
@article{Xiao2026,
  author = {Xiao, Jingyi and Li, Tongtong and Sun, Jianing and Gao, Xue},
  title = {Target-inhibited MCOF-Apt@Ag self-assembly for multi-modal biosensor for detecting Vibrio parahaemolyticus},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2025.118248}
}
Kostenlos starten →