Self-driven microfluidic chip with integrated lateral and vertical flow assays for dual-readout point-of-care testing
Biosensors and Bioelectronics · 2026
DOI: 10.1016/j.bios.2025.118247 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Qifan Zhou und 9 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 211189, Chi…. Hauptthemen laut MEDLINE: Point-of-Care Testing, Biosensing Techniques, Interleukin-6, Lab-On-A-Chip Devices. Die Arbeit nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Planning Project of Shenzhen Municipality.
Abstract (Originalsprache)
Rapid and sensitive detection of biomarkers is pivotal for disease prevention and control in point-of-care testing (POCT). Traditional nitrocellulose (NC) membrane-based lateral flow assay (LFA) often cause suboptimal sensitivity and poor uniformity by disordered porous structure. Herein, we propose a self-driven microfluidic chip with integrated lateral and vertical flow assays (VFA), termed the SeDM-LV chip. By replacing the test line in LFA with an anodized aluminum oxide (AAO) membrane and incorporating surface-enhanced Raman scattering (SERS), the chip enables rapid, highly sensitive, and reproducible detection of target biomarkers. Taking Interleukin 6 (IL-6) as a proof of concept, the optimized chip demonstrates adequate detection performance, with naked-eye and SERS-based detection limits of 100 pg/mL and 0.95 pg/mL. The calibration curve exhibits a linear dynamic range spanning from 1 pg/mL to 1 μg/mL (R2 = 0.972), while the one-step "sample-to-answer" protocol is completed only within 5 min. Chip evaluation revealed recoveries ranging from 92.1 % to 109 % in spiked healthy human serum for IL-6 quantification, alongside effective differentiate on between IL-6 abnormal (n = 8) and normal (n = 4) groups in clinical serum samples. Conceptually, this represents the first achievement of synergistic optimization of LFA and VFA, overcoming the long-standing trade-off between speed, sensitivity and user-friendliness in conventional POCT. The integrated chip features portability, simplicity, low cost and high expandability, rendering it highly significant for primary care screening and on-site detection during public health emergencies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 211189, China; Southeast University Shenzhen Research Institute, Shenzhen, 518000…
- State International Joint Research Center for Animal Health Breeding, College of Animal Science and Technology, Shihezi University, Shihezi, 832003, China.
- Rehabilitation Medical Center, The First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China.
- State International Joint Research Center for Animal Health Breeding, College of Animal Science and Technology, Shihezi University, Shihezi, 832003, China. Electronic address: prof.zhang@foxmail.com.
- College of Software, Xinjiang University, Urumqi, 830046, China.
Förderung
- National Natural Science Foundation of China
- Science and Technology Planning Project of Shenzhen Municipality
Zitieren
APA
Zhou, Q., Lu, Y., Li, M., Qi, C., Sun, X., Zhang, H., Sheng, J., Chen, C., Lv, X., & Zhao, X. (2026). Self-driven microfluidic chip with integrated lateral and vertical flow assays for dual-readout point-of-care testing. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.118247
Vancouver
Zhou Q, Lu Y, Li M, Qi C, Sun X, Zhang H, et al. Self-driven microfluidic chip with integrated lateral and vertical flow assays for dual-readout point-of-care testing. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2025.118247
BibTeX
@article{Zhou2026,
author = {Zhou, Qifan and Lu, Yu and Li, Miaomiao and Qi, Chuang and Sun, Xiaoxuan and Zhang, Hui and Sheng, Jinliang and Chen, Cheng and Lv, Xiaoyi and Zhao, Xiangwei},
title = {Self-driven microfluidic chip with integrated lateral and vertical flow assays for dual-readout point-of-care testing},
journal = {Biosensors and Bioelectronics},
year = {2026},
doi = {10.1016/j.bios.2025.118247}
}
EUVIMED