EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ammonia colourimetric indicator for measuring urease and ureolytic bacteria concentrations

Michaella Watson, Christopher O'Rourke, Andrew Mills

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2025.118238 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Michaella Watson und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Queens University Belfast, Stranmillis Road, Belfast, BT9 5AG, UK. Hauptthemen laut MEDLINE: Urease, Colorimetry, Ammonia, Biosensing Techniques. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An effectively irreversible colourimetric ammonia (NH3) indicator is used to develop two new methods for determining the concentrations of, (i) urease [urease], and (ii) ureolytic bacteria under aerobic and anaerobic conditions. In both methods digital colour analysis (DCA) of a photographic image of the indicator is used to provide a value for the apparent absorbance, A', which reflects the level of NH3 present. In (i) the indicator is placed in a solution containing urea and the urease sample under test, and photographed as a function of incubation time, t. DCA of the photographs yields an A' vs t plot, from which a value for the time taken for the indicator to reach its half-way colour changing point, t50, is determined, the reciprocal of which is directly proportional to [urease]. In (ii), the indicator is placed in a Falcon™ tube containing a urea-based growth medium inoculated with a ureolytic bacterium of known concentration (units: CFU/mL), and photographed as a function of t. The resulting 'S' shaped A' vs t profile is used to determine a value of the half-way colour change, the threshold time, TT, which is shown to be directly proportional to log(CFU/mL) over the range 101-108 CFU/mL for ureolytic bacteria such as P. stuartii and P. mirabilis, even in the presence of a non-ureolytic bacterial species, such as E. coli. The latter novel NH3 indicator based micro-respirometry method for measuring TVC (NH3 μR-TVC) works under anaerobic and aerobic conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

UreaseColorimetryAmmoniaBiosensing TechniquesUreaBacteria

Stichwörter der Autor:innen

AmmoniaBacteriaIndicatorMicrorespirometryTVCUrease

Substanzen

UreaseAmmoniaUrea

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, Queens University Belfast, Stranmillis Road, Belfast, BT9 5AG, UK.
  • School of Chemistry and Chemical Engineering, Queens University Belfast, Stranmillis Road, Belfast, BT9 5AG, UK. Electronic address: andrew.mills@qub.ac.uk.

Förderung

  • Engineering and Physical Sciences Research Council

Zitieren

APA

Watson, M., O'Rourke, C., & Mills, A. (2026). Ammonia colourimetric indicator for measuring urease and ureolytic bacteria concentrations. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.118238

Vancouver

Watson M, O'Rourke C, Mills A. Ammonia colourimetric indicator for measuring urease and ureolytic bacteria concentrations. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2025.118238

BibTeX
@article{Watson2026,
  author = {Watson, Michaella and O'Rourke, Christopher and Mills, Andrew},
  title = {Ammonia colourimetric indicator for measuring urease and ureolytic bacteria concentrations},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2025.118238}
}
Kostenlos starten →