EUVIMEDEUVIMED entdecken
Crossref

Dual-mode sensor array based on silica-coated carbon dots with tunable fluorescence and phosphorescence for discrimination and detection of monoamine neurotransmitters

Yongbo Wang, Yuanna Ning, Yanting Jia, Shaojie Wang, Wencai Wang, Chengyuan Liang, Yingkun Ren

Biosensors and Bioelectronics · 2026-02 · 294 · 118224

DOI: 10.1016/j.bios.2025.118224 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-02. Verfasst von Yongbo Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Biological and Pharmaceutical Sciences, Shaanxi University of Science and Technology, Xi'an, 710021, PR China; School of Food Science and E…. Hauptthemen laut MEDLINE: Silicon Dioxide, Biosensing Techniques, Neurotransmitter Agents, Quantum Dots. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Shaanxi Provincial Science and Technology Department, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Detection and discrimination of monoamine neurotransmitters (MNTs) are critical for early diagnosis but remain a substantial challenge due to their similar molecular structures and the complex interferences from biological sample matrices. Herein, dual-mode (fluorescence/phosphorescence) sensor arrays based on silica-coated carbon dots (CDs@SiO2) were developed for discrimination and detection of multiple MNTs. The synthesized CDs@SiO2 displayed dual fluorescence (395 nm) and phosphorescence (520 nm) emission, enabling a one-component dual-mode sensor array for discrimination of catecholamines (100 % accuracy). The CDs-RhB@SiO2 nanocomposites, prepared by co-confining CDs and rhodamine B (RhB) in silica, exhibited orange fluorescence (585 nm) and red phosphorescence (600 nm). This structure enables efficient FRET (77.4 %) from CDs to RhB, yielding long-wavelength phosphorescence. Subsequently, a two-component four-channel sensor array utilizing CDs@SiO2 and CDs-RhB@SiO2 was developed. By leveraging distinct fluorescence (λem = 395/585 nm) and phosphorescence (λem = 520/600 nm) signals, the sensor array achieved precise discrimination (100 % accuracy) and quantitative detection of multiple MNTs with a low detection limit of 1.25 μM. This work provides a strategy to develop multimode sensor arrays with low background interference, demonstrating promise as a proof-of-concept platform that may support early diagnostic applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Silicon DioxideBiosensing TechniquesNeurotransmitter AgentsQuantum DotsCatecholaminesCarbonLimit of DetectionHumansLuminescent MeasurementsRhodaminesFluorescent DyesFluorescenceSpectrometry, Fluorescence

Stichwörter der Autor:innen

Dual-mode sensor arrayFluorescenceMonoamine neurotransmittersPhosphorescenceSilica-coated carbon dots

Substanzen

Silicon DioxideCarbonNeurotransmitter Agentsrhodamine BRhodaminesFluorescent DyesCatecholamines

Autor:innen und Institutionen

  • School of Biological and Pharmaceutical Sciences, Shaanxi University of Science and Technology, Xi'an, 710021, PR China; School of Food Science and Engineering, Shaanxi University of Science and Technology, Xi'an, 71002…
  • School of Biological and Pharmaceutical Sciences, Shaanxi University of Science and Technology, Xi'an, 710021, PR China.
  • School of Life Science, Xinghuacun College, Shanxi University, Taiyuan, 030006, PR China.
  • Shaanxi Coal Testing Technology Co., Ltd, PR China.

Förderung

  • Shaanxi Provincial Science and Technology Department
  • National Natural Science Foundation of China

Zitieren

APA

Wang, Y., Ning, Y., Jia, Y., Wang, S., Wang, W., Liang, C., & Ren, Y. (2026). Dual-mode sensor array based on silica-coated carbon dots with tunable fluorescence and phosphorescence for discrimination and detection of monoamine neurotransmitters. Biosensors and Bioelectronics, 294, 118224. https://doi.org/10.1016/j.bios.2025.118224

Vancouver

Wang Y, Ning Y, Jia Y, Wang S, Wang W, Liang C, et al. Dual-mode sensor array based on silica-coated carbon dots with tunable fluorescence and phosphorescence for discrimination and detection of monoamine neurotransmitters. Biosensors and Bioelectronics. 2026;294:118224. doi:10.1016/j.bios.2025.118224

BibTeX
@article{Wang2026,
  author = {Wang, Yongbo and Ning, Yuanna and Jia, Yanting and Wang, Shaojie and Wang, Wencai and Liang, Chengyuan and Ren, Yingkun},
  title = {Dual-mode sensor array based on silica-coated carbon dots with tunable fluorescence and phosphorescence for discrimination and detection of monoamine neurotransmitters},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {294},
  pages = {118224},
  doi = {10.1016/j.bios.2025.118224}
}
Kostenlos starten →