Real-time and continuous monitoring of hypochlorous acid using a wearable sensor based on boronic acid nanofibers and gold nanoparticles
Biosensors and Bioelectronics · 2026-02 · 294 · 118210
DOI: 10.1016/j.bios.2025.118210 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-02. Verfasst von Murugan Thiruppathi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Bioanalytical Chemistry and Nanobiomedicine Laboratory, Department of Biochemical Science and Technology, National Taiwan University, Taipei, 10617, …. Hauptthemen laut MEDLINE: Metal Nanoparticles, Wearable Electronic Devices, Hypochlorous Acid, Biosensing Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: National Taiwan University, National Science and Technology Council.
Abstract (Originalsprache)
Hypochlorous acid (HOCl) is a widely used disinfectant, but excessive exposure can harm humans and plants. Given its widespread use and the likelihood of exposure on surfaces from agricultural and domestic products, there is a critical need for high-throughput, sensitive, and reliable protocols to monitor HOCl levels on plant surfaces and human skin. Conventional electrochemical sensors and the standard N, N-diethyl-p-phenylenediamine (DPD) spectrophotometric method are unsuitable for real-time or on-site detection. We developed a wearable electrochemical sensor integrated with smartphone technology for sensitive HOCl monitoring to address this. The sensor employs a screen-printed carbon electrode (SPCE) modified with polyaminophenylboronic acid (PAPBA) nanofibers and gold nanoparticles (AuNPs), which enhance conductivity and specificity. The modified electrode was thoroughly characterized by surface, functional, and electrochemical analyses, confirming successful fabrication and stability. The device exhibited a wide linear range (10 μM-10 mM) and a low detection limit (0.19 μM). Its practical utility was demonstrated by analyzing HOCl levels in pool water, floor cleaner, and sanitizer, as well as directly on plant leaves and pig skin, highlighting adaptability for smart farming and bioscience research. Reliability was ensured by cross-confirmation with the DPD method, validating accuracy and consistency across diverse environmental contexts.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Bioanalytical Chemistry and Nanobiomedicine Laboratory, Department of Biochemical Science and Technology, National Taiwan University, Taipei, 10617, Taiwan.
- Bioanalytical Chemistry and Nanobiomedicine Laboratory, Department of Biochemical Science and Technology, National Taiwan University, Taipei, 10617, Taiwan; Department of Chemistry, National Taiwan University, Taipei, 1…
Förderung
- National Taiwan University
- National Science and Technology Council
Zitieren
APA
Thiruppathi, M., Velusamy, N., Lin, P. Y., & Ho, J. A. (2026). Real-time and continuous monitoring of hypochlorous acid using a wearable sensor based on boronic acid nanofibers and gold nanoparticles. Biosensors and Bioelectronics, 294, 118210. https://doi.org/10.1016/j.bios.2025.118210
Vancouver
Thiruppathi M, Velusamy N, Lin PY, Ho JA. Real-time and continuous monitoring of hypochlorous acid using a wearable sensor based on boronic acid nanofibers and gold nanoparticles. Biosensors and Bioelectronics. 2026;294:118210. doi:10.1016/j.bios.2025.118210
BibTeX
@article{Thiruppathi2026,
author = {Thiruppathi, Murugan and Velusamy, Nithya and Lin, Pei-Ying and Ho, Ja-An Annie},
title = {Real-time and continuous monitoring of hypochlorous acid using a wearable sensor based on boronic acid nanofibers and gold nanoparticles},
journal = {Biosensors and Bioelectronics},
year = {2026},
volume = {294},
pages = {118210},
doi = {10.1016/j.bios.2025.118210}
}
EUVIMED