EUVIMEDEUVIMED entdecken
Crossref

Interface-regulated MOF/g-C3N4 heterostructure for electrode passivation elimination: Ultrasensitive electrochemiluminescence sensing of CA15–3 via ECL-RET

Xue Dong, Qingze Zeng, Jiangle Yi, Yu Du, Yamei Li, Tingting Wu, Faying Li, Qin Wei

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2025.118171 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Xue Dong und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, Collaborative In…. Hauptthemen laut MEDLINE: Biosensing Techniques, Metal-Organic Frameworks, Electrochemical Techniques, Graphite. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shandong Province Natural Science Foundation, China Postdoctoral Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of stable and efficient luminophores remains a critical challenge in electrochemiluminescence (ECL) sensing. Graphitic carbon nitride (g-C3N4) has emerged as a promising luminophore due to its high stability and low toxicity, yet its practical application is constrained by limited surface area, poor conductivity, and severe electrode passivation. Herein, a metal-organic framework (MOF)/g-C3N4 (NH2-UiO-66/g-C3N4, NUCN) heterostructure luminophore was constructed via interface engineering. The integration of NH2-UiO-66 (NU) remarkably enhanced electrical conductivity, surface area and ECL efficiency of g-C3N4. Mechanistically, the low LUMO level of NU enabled efficient electron capture from the conduction band of g-C3N4, which eradicated electrode passivation and directly contributed to the 4.6 % enhancement in ECL efficiency. Concurrently, the NUCN heterostructure featured increased Brunauer-Emmett-Teller (BET) surface area and abundant amino groups, collectively enhancing its antibody loading capacity for biomolecular recognition. This dual improvement-electron transfer optimization for ECL performance and structural modification for biomolecule immobilization-collectively enabled the ultrasensitive sensing capability of the NUCN-based platform. In addition, the absorption spectrum of PANI-sCuO quencher exhibited strong overlap with the ECL emission of NUCN at 452 nm, enabling ECL resonance energy transfer (ECL-RET)-mediated signal quenching. This allowed target-induced quenching to generate pronounced ECL intensity variation, thereby achieving ultrasensitive detection via signal amplification. Leveraging the NUCN/PANI-sCuO system, a sandwich-type immunosensor was developed for carbohydrate antigen 15-3 (CA15-3), featuring a linear range of 0.05-600 U/mL and a detection limit of 0.02 U/mL, demonstrating its potential for clinical biomarker analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesMetal-Organic FrameworksElectrochemical TechniquesGraphiteLuminescent MeasurementsNitrogen CompoundsHumansLimit of DetectionElectrodesPhthalic Acids

Stichwörter der Autor:innen

CA15-3ElectrochemiluminescenceElectrode passivationHeterostructureInterface regulation

Substanzen

Metal-Organic FrameworksGraphitegraphitic carbon nitrideNitrogen CompoundsUiO-66Phthalic Acids

Autor:innen und Institutionen

  • Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, Collaborative Innovation Center for Green Chemical Manufacturing and Accurate Detectio…
  • School of Water Conservancy and Environment, University of Jinan, Jinan, 250022, PR China.

Förderung

  • National Natural Science Foundation of China
  • Shandong Province Natural Science Foundation
  • China Postdoctoral Science Foundation

Zitieren

APA

Dong, X., Zeng, Q., Yi, J., Du, Y., Li, Y., Wu, T., Li, F., & Wei, Q. (2026). Interface-regulated MOF/g-C3N4 heterostructure for electrode passivation elimination: Ultrasensitive electrochemiluminescence sensing of CA15–3 via ECL-RET. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.118171

Vancouver

Dong X, Zeng Q, Yi J, Du Y, Li Y, Wu T, et al. Interface-regulated MOF/g-C3N4 heterostructure for electrode passivation elimination: Ultrasensitive electrochemiluminescence sensing of CA15–3 via ECL-RET. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2025.118171

BibTeX
@article{Dong2026,
  author = {Dong, Xue and Zeng, Qingze and Yi, Jiangle and Du, Yu and Li, Yamei and Wu, Tingting and Li, Faying and Wei, Qin},
  title = {Interface-regulated MOF/g-C3N4 heterostructure for electrode passivation elimination: Ultrasensitive electrochemiluminescence sensing of CA15–3 via ECL-RET},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2025.118171}
}
Kostenlos starten →