EUVIMEDEUVIMED entdecken
Crossref

Reduced graphene oxide modified screen-printed electrode with bioengineered surface for voltammetric detection of prostate-specific antigen in oncological urine samples

Mohammad Rizwan, Diana M Bobrowska, Michał Półtorak, Irena Walecka, Paweł Banatkiewicz, Marcin Włodarczyk, Karolina Rudnicka, Lukasz Poltorak

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2025.118144 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Mohammad Rizwan und 7 weiteren Autor:innen. Beteiligte Einrichtung: Electrochemistry@Soft Interfaces (E@SI) Group, Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, Tamka 12, …. Hauptthemen laut MEDLINE: Graphite, Prostate-Specific Antigen, Biosensing Techniques, Electrochemical Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben. Gefördert von: Uniwersytet Łódzki.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this work, reduced graphene oxide modified screen-printed electrode modified with anti-prostate specific antigen (anti-PSA linked using N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide) was developed for early electrochemical detection of PSA. Constructed sensing interface gave linear dynamic range from 0.10 fg mL-1 to 100.00 ng mL-1 with a calculated limit of detection 0.10 fg mL-1, low limit of quantification 1.04 fg mL-1 and high sensitivity 10.02 μA mL·ng-1. PSA detection was done in artificial urine and commercial serum, respectively, in the RSD range of 4.02-4.57 and 1.72 to 2.0. Moreover, a developed nanoimmunochip was applied to successfully detect the PSA in two oncological urine samples, further verified by ELISA. Finally, a nanoimmunochip stored at -20 °C for 60 days demonstrated comparable performance to a freshly developed platform.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteProstate-Specific AntigenBiosensing TechniquesElectrochemical TechniquesProstatic NeoplasmsHumansMaleLimit of DetectionElectrodesAntibodies, ImmobilizedEquipment Design

Stichwörter der Autor:innen

Electrochemical immunosensorProstate cancerProstate-specific antigenReduced graphene oxide modified screen-printed electrodeVoltammetry

Substanzen

GraphiteProstate-Specific Antigengraphene oxideAntibodies, Immobilized

Autor:innen und Institutionen

  • Electrochemistry@Soft Interfaces (E@SI) Group, Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, Tamka 12, 91-403, Lodz, Poland. Electronic address: mohammad.rizwan@chemia.uni.l…
  • Faculty of Chemistry, University of Bialystok, Ciolkowskiego 1K, 15-245, Bialystok, Poland.
  • The National Institute of Medicine of the Ministry of the Interior and Administration, Warsaw, Poland.
  • Department of Immunology and Infectious Biology, Faculty of Biology and Environmental Protection, University of Lodz, Banacha 12/16, 90-237, Lodz, Poland.
  • Electrochemistry@Soft Interfaces (E@SI) Group, Department of Inorganic and Analytical Chemistry, Faculty of Chemistry, University of Lodz, Tamka 12, 91-403, Lodz, Poland. Electronic address: lukasz.poltorak@chemia.uni.l…

Förderung

  • Uniwersytet Łódzki

Zitieren

APA

Rizwan, M., Bobrowska, D. M., Półtorak, M., Walecka, I., Banatkiewicz, P., Włodarczyk, M., Rudnicka, K., & Poltorak, L. (2026). Reduced graphene oxide modified screen-printed electrode with bioengineered surface for voltammetric detection of prostate-specific antigen in oncological urine samples. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.118144

Vancouver

Rizwan M, Bobrowska DM, Półtorak M, Walecka I, Banatkiewicz P, Włodarczyk M, et al. Reduced graphene oxide modified screen-printed electrode with bioengineered surface for voltammetric detection of prostate-specific antigen in oncological urine samples. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2025.118144

BibTeX
@article{Rizwan2026,
  author = {Rizwan, Mohammad and Bobrowska, Diana M and Półtorak, Michał and Walecka, Irena and Banatkiewicz, Paweł and Włodarczyk, Marcin and Rudnicka, Karolina and Poltorak, Lukasz},
  title = {Reduced graphene oxide modified screen-printed electrode with bioengineered surface for voltammetric detection of prostate-specific antigen in oncological urine samples},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2025.118144}
}
Kostenlos starten →