EUVIMEDEUVIMED entdecken
Crossref

Surface plasmonic coupling-electrochemiluminescence biosensor based on Hf-nanoMOF/square-cavity Au nanostar@CuS nanocube array for the detection of miRNA-9 in glioma diagnosis

Wenyan Li, Zihui Liang, Peilin Wang, Zhenrun Li, Qiang Ma

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2025.117908 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Wenyan Li und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China. Hauptthemen laut MEDLINE: MicroRNAs, Biosensing Techniques, Glioma. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Jilin Province People's Government, Jilin University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The integration of luminescent materials with plasmonic nanomaterials holds the potential to give rise to innovative analytical and sensing applications. In this study, novel nano-scaled luminescent Hf-MOF (Hf-nanoMOF) was prepared by the modulator-induced defect approach. Acetate was used as a modulator to preferentially coordinate with metal centers, which inhibited the formation of coordination bond between the metal clusters and 2-aminobenzene-1,4-dicarboxylic acid and limited the Ostwald ripening effect. The Hf-nanoMOF displayed excellent anodic electrochemiluminescence (ECL) performance, with the ligand 2-aminobenzene-1,4-dicarboxylic acid acting as the luminescence center. Furthermore, the square-cavity Au nanostar@CuS nanocubes array was prepared to produce dense hot spots, ensuring uniform and stable field enhancement. Therefore, the square-cavity Au nanostar@CuS nanocubes array significantly enhanced the luminescence intensity of Hf-nanoMOF due to the surface plasmonic coupling (SPC) effect by 5.8 times. The SPC-ECL sensor based on the Hf-nanoMOF/Au nanostar@CuS nanocubes array was applied to detect miRNA-9 with a wide detection range from 1 fM to 1 nM and a detection limit of 0.35 fM. Moreover, the proposed biosensor can be employed to effectively differentiate between glioma tumor tissue and adjacent tissue, which shows great potential as a diagnostic tool.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroRNAsBiosensing TechniquesGliomaGoldHumansLuminescent MeasurementsElectrochemical TechniquesLimit of DetectionMetal-Organic FrameworksMetal NanoparticlesNanostructuresCopper

Stichwörter der Autor:innen

ElectrochemiluminescenceGlioma diagnosisNano-scaled luminescent Hf-MOFSurface plasmonic coupling effectmiRNA-9 detection

Substanzen

MicroRNAsGoldMetal-Organic FrameworksCopper

Autor:innen und Institutionen

  • Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China.
  • Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China. Electronic address: qma@jlu.edu.cn.

Förderung

  • National Natural Science Foundation of China
  • Jilin Province People's Government
  • Jilin University
  • Education Department of Jilin Province
  • Foundation for Innovative Research Groups of the National Natural Science Foundation of China

Zitieren

APA

Li, W., Liang, Z., Wang, P., Li, Z., & Ma, Q. (2025). Surface plasmonic coupling-electrochemiluminescence biosensor based on Hf-nanoMOF/square-cavity Au nanostar@CuS nanocube array for the detection of miRNA-9 in glioma diagnosis. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117908

Vancouver

Li W, Liang Z, Wang P, Li Z, Ma Q. Surface plasmonic coupling-electrochemiluminescence biosensor based on Hf-nanoMOF/square-cavity Au nanostar@CuS nanocube array for the detection of miRNA-9 in glioma diagnosis. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117908

BibTeX
@article{Li2025,
  author = {Li, Wenyan and Liang, Zihui and Wang, Peilin and Li, Zhenrun and Ma, Qiang},
  title = {Surface plasmonic coupling-electrochemiluminescence biosensor based on Hf-nanoMOF/square-cavity Au nanostar@CuS nanocube array for the detection of miRNA-9 in glioma diagnosis},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117908}
}
Kostenlos starten →