CRISPR/Cas13a-driven lateral flow assay for preamplification-free and ultrasensitive miRNA-21 detection
Biosensors and Bioelectronics · 2025-11 · 288 · 117850
DOI: 10.1016/j.bios.2025.117850 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-11. Verfasst von Yan Zhu und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen, Guangdong, 518060, PR China. Hauptthemen laut MEDLINE: MicroRNAs, Biosensing Techniques, CRISPR-Cas Systems. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: National Key Research and Development Program of China.
Abstract (Originalsprache)
Developing a preamplification-free and sensitive clustered regularly interspaced short palindromic repeats (CRISPR)-based method is significant but still extremely challenging for microRNA (miRNA) detection. Here we present a combination of a CRISPR/Cas13a-based reaction with a lateral flow biosensor, which enables the quantitative and colorimetric readout of preamplification-free miRNA detection at room temperature. In this work, the reaction principle and the structure of the lateral flow strip are well-designed to achieve surface-enhanced Raman scattering (SERS)/colorimetric dual-signal "turn-on" response of target miRNA. The CRISPR/Cas13a Reporter is engineered with a DNA-RNA splicing structure to generate DNA cleavage products and reduce nonspecific collateral cleavage. Without the need for nucleic acid preamplification strategy, the developed CRISPR/Cas13a-driven lateral flow biosensor enables the microRNA-21 (miR-21) detection at room temperature with a readout time of 10 min and a total process time of less than 45 min, achieving an impressive limit of detection of 8.96 aM by SERS and 1 fM by visualization, respectively. Moreover, the platform demonstrated excellent recovery rates in spiked human serum samples. The proposed CRISPR/Cas13a-driven, dual-signal "turn-on"-responded lateral flow platform has the potential to simultaneously meet the requirements of convenient point-of-care visualization detection and more accurate and sensitive SERS detection of miR-21, offering a cost-effective, rapid, and reliable tool for early cancer diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen, Guangdong, 518060, PR China.
- Department of Clinical Laboratory, Shenzhen Institute of Translational Medicine, The First Affiliated Hospital of Shenzhen University, Shenzhen Second People's Hospital, Shenzhen, Guangdong, 518060, PR China.
- Beijing Key Laboratory for Bioengineering and Sensing Technology, University of Science and Technology Beijing, Beijing, 100083, PR China. Electronic address: yanhuang@ustb.edu.cn.
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen, Guangdong, 518060, PR China. Electronic address: yzliu@szu.edu.cn.
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen, Guangdong, 518060, PR China. Electronic address: conghuiliu@szu.edu.cn.
Förderung
- National Key Research and Development Program of China
Zitieren
APA
Zhu, Y., Lai, J., Yang, X., Wang, S., Gu, D., Huang, Y., Liu, Y., & Liu, C. (2025). CRISPR/Cas13a-driven lateral flow assay for preamplification-free and ultrasensitive miRNA-21 detection. Biosensors and Bioelectronics, 288, 117850. https://doi.org/10.1016/j.bios.2025.117850
Vancouver
Zhu Y, Lai J, Yang X, Wang S, Gu D, Huang Y, et al. CRISPR/Cas13a-driven lateral flow assay for preamplification-free and ultrasensitive miRNA-21 detection. Biosensors and Bioelectronics. 2025;288:117850. doi:10.1016/j.bios.2025.117850
BibTeX
@article{Zhu2025,
author = {Zhu, Yan and Lai, Junwei and Yang, Xinyao and Wang, Shuqing and Gu, Dayong and Huang, Yan and Liu, Yizhen and Liu, Conghui},
title = {CRISPR/Cas13a-driven lateral flow assay for preamplification-free and ultrasensitive miRNA-21 detection},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {288},
pages = {117850},
doi = {10.1016/j.bios.2025.117850}
}
EUVIMED