Development of a universal one-pot CRISPR assay based on multifunctional tagged primer eliminating unstable crRNA input and PAM dependency for point-of-care detection of bacterial infections
Biosensors and Bioelectronics · 2025
DOI: 10.1016/j.bios.2025.117718 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Xiaofan Zhu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nutrition and Food Hygiene, School of Public Health, Anhui Medical University, Hefei, 230032, Anhui, PR China. Hauptthemen laut MEDLINE: CRISPR-Cas Systems, Biosensing Techniques, Bacterial Infections. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: University Natural Science Research Project of Anhui Province, Anhui Provincial Natural Science Foundation, Key Technologies Research and Development Program.
Abstract (Originalsprache)
The integration of recombinase polymerase amplification (RPA) with CRISPR/Cas12a holds great promise for point-of-care assay of bacterial infections, but still confronts challenges such as the input of unstable RNA, dependence on PAM, and multi-step operations. To address these challenges, we here present a tagged primer-based one-pot CRISPR/Cas12a assay, called TOP-CRISPR. Strategically, TOP-CRISPR utilized target gene-induced amplicons to generate crRNA sequences with the help of T7 RNA polymerase, thus eliminating the need for additional crRNA. The resulting Cas12a/crRNA complex were activated by the tag sequences at the end of specific primers rather than by the target amplicons, avoiding dependence on the PAM and disruption of the target amplicon by CRISPR/Cas12a. The ingenious design of tagged primer enables perfect compatibility between RPA and CRISPR/Cas12a system in a closed single tube, which is expected to overcome aerosol contamination caused by multi-step and open-cap operations. Under optimal conditions, the method was able to detect target bacteria down to ∼1 CFU/mL and the entire process took only less than 50 min, which is significantly better than the traditional two-step or one-step methods. By grafting the tag sequence onto different specific primers, bacteria such as Staphylococcus aureus, Escherichia coli O157:H7 and Pseudomonas aeruginosa has been detected, respectively. The practicability and robustness of the method was further validated by real samples. We hope that the method can be developed into a point-of-care detection tool for bacterial infections.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Nutrition and Food Hygiene, School of Public Health, Anhui Medical University, Hefei, 230032, Anhui, PR China.
- School of Food and Biological Engineering, Hefei University of Technology, Hefei, 230009, Anhui, PR China.
- The Second Clinical Medical College, Anhui Medical University, Hefei, 230032, PR China.
- School of Life Sciences, Anhui Medical University, Hefei, 230032, Anhui, PR China.
- Department of Nutrition and Food Hygiene, School of Public Health, Anhui Medical University, Hefei, 230032, Anhui, PR China. Electronic address: lqb051@126.com.
- Department of Nutrition and Food Hygiene, School of Public Health, Anhui Medical University, Hefei, 230032, Anhui, PR China. Electronic address: 15205519023@163.com.
Förderung
- University Natural Science Research Project of Anhui Province
- Anhui Provincial Natural Science Foundation
- Key Technologies Research and Development Program
- Anhui Science and Technology Department
- Anhui Medical University
- National Key Research and Development Program of China
- National Natural Science Foundation of China
Zitieren
APA
Zhu, X., Jiao, J., Ni, Q., Yao, L., Zhang, Y., Liu, K., Huang, L., Bo, Q., & Qin, P. (2025). Development of a universal one-pot CRISPR assay based on multifunctional tagged primer eliminating unstable crRNA input and PAM dependency for point-of-care detection of bacterial infections. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117718
Vancouver
Zhu X, Jiao J, Ni Q, Yao L, Zhang Y, Liu K, et al. Development of a universal one-pot CRISPR assay based on multifunctional tagged primer eliminating unstable crRNA input and PAM dependency for point-of-care detection of bacterial infections. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117718
BibTeX
@article{Zhu2025,
author = {Zhu, Xiaofan and Jiao, Jingran and Ni, Qun and Yao, Li and Zhang, Yule and Liu, Kaiyong and Huang, Lin and Bo, Qingli and Qin, Panzhu},
title = {Development of a universal one-pot CRISPR assay based on multifunctional tagged primer eliminating unstable crRNA input and PAM dependency for point-of-care detection of bacterial infections},
journal = {Biosensors and Bioelectronics},
year = {2025},
doi = {10.1016/j.bios.2025.117718}
}
EUVIMED