Target responsive-regulated CRISPR/Cas12a electrochemiluminescence sensing of salmonella typhimurium integrating ultrafine Pt NCs-anchored MXenes-boosted luminol/O2 system
Biosensors and Bioelectronics · 2025-09 · 283 · 117558
DOI: 10.1016/j.bios.2025.117558 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-09. Verfasst von Xiaobo Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Biotechnology and Bioresources Utilization of Ministry of Education, School of Life Sciences, Dalian Minzu University, Dalian, 1166…. Hauptthemen laut MEDLINE: Salmonella typhimurium, Biosensing Techniques. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China.
Abstract (Originalsprache)
Salmonella typhimurium (S. typhimurium), as common and highly pathogenic foodborne pathogen, poses a significant risk to public safety worldwide. The development of highly sensitive, rapid and on-site method for S. typhimurium analysis is urgently needed to prevent bacterial infections. Herein, we introduced a CRISPR/Cas12a-driven electrochemiluminescence (ECL) sensor based on luminol/O2 binary systems for S. typhimurium detection, employing ultrafine Pt nanoclusters-anchored 2D delaminated-MXenes (Pt NCs/D-MXenes) as the co-reactant accelerator. The ultrathin D-MXenes support regulates the size and dispersibility of Pt NCs and facilitates the full exposure of active sites, and synergistic interactions between D-MXenes and Pt NCs improves electrocatalytic properties toward the reduction of O2, which promotes the generation of ROS for boosting ECL emission. Using target responsive-regulated CRISPR/Cas12a system, the ECL sensor for S. typhimurium showed a broad concentration range from 101 to 106 CFU/mL and limit of detection of 6 CFU/mL, with satisfactory recoveries in spiked-actual samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Biotechnology and Bioresources Utilization of Ministry of Education, School of Life Sciences, Dalian Minzu University, Dalian, 116600, China.
- Food Laboratory of Zhongyuan, Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, China Agricultural University, Beijing, 100193, China.
- Zhuanghe Food Inspection and Monitoring Center, Dalian, Liaoning Province, 116400, China. Electronic address: zhu40511516@163.com.
- Food Laboratory of Zhongyuan, Key Laboratory of Precision Nutrition and Food Quality, Department of Nutrition and Health, China Agricultural University, Beijing, 100193, China. Electronic address: xuwentao@cau.edu.cn.
- Key Laboratory of Biotechnology and Bioresources Utilization of Ministry of Education, School of Life Sciences, Dalian Minzu University, Dalian, 116600, China. Electronic address: caojijuan@dlnu.edu.cn.
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program of China
Zitieren
APA
Zhang, X., Wang, X., Zhu, L., Zhu, J., Zheng, Q., Yuan, J., Xu, W., & Cao, J. (2025). Target responsive-regulated CRISPR/Cas12a electrochemiluminescence sensing of salmonella typhimurium integrating ultrafine Pt NCs-anchored MXenes-boosted luminol/O2 system. Biosensors and Bioelectronics, 283, 117558. https://doi.org/10.1016/j.bios.2025.117558
Vancouver
Zhang X, Wang X, Zhu L, Zhu J, Zheng Q, Yuan J, et al. Target responsive-regulated CRISPR/Cas12a electrochemiluminescence sensing of salmonella typhimurium integrating ultrafine Pt NCs-anchored MXenes-boosted luminol/O2 system. Biosensors and Bioelectronics. 2025;283:117558. doi:10.1016/j.bios.2025.117558
BibTeX
@article{Zhang2025,
author = {Zhang, Xiaobo and Wang, Xiuwen and Zhu, Longjiao and Zhu, Jinyan and Zheng, Qiuyue and Yuan, Jingli and Xu, Wentao and Cao, Jijuan},
title = {Target responsive-regulated CRISPR/Cas12a electrochemiluminescence sensing of salmonella typhimurium integrating ultrafine Pt NCs-anchored MXenes-boosted luminol/O2 system},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {283},
pages = {117558},
doi = {10.1016/j.bios.2025.117558}
}
EUVIMED