EUVIMEDEUVIMED entdecken
Crossref

Development of an activity-based ratiometric electrochemical substrate for measuring circulating dipeptidyl peptidase-IV/CD26 in whole blood samples

Namasivayam Kumaragurubaran, Hou Po Yun, Antanas Zinovicius, Sheng-Tung Huang, Ponnusamy Arul, Hsin-Yi Lin, Ou Min-Shin, Inga Morkvenaite-Vilkonciene

Biosensors and Bioelectronics · 2025-09 · 283 · 117538

DOI: 10.1016/j.bios.2025.117538 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-09. Verfasst von Namasivayam Kumaragurubaran und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei, 106, Taiwan, ROC; Institute of Biochemical an…. Hauptthemen laut MEDLINE: Dipeptidyl Peptidase 4, Biosensing Techniques, Electrochemical Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: National Taipei University of Technology, National Science and Technology Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dipeptidyl peptidase-IV (DPP-IV) is a circulating blood biomarker that diagnose pancreatic and thyroid cancers, as well as type 2 diabetes. Although current DPP-IV detection methods show promise, real-time detection in whole blood is limited, as blood samples require tedious pre-treatment. To overcome these limitations, a DPP-IV targeted electrochemical substrate, DPPLPOH (DiPeptidyl Peptidase Latent Probe-OH (with Hydroxyl group)), was designed. When coupled with an electrochemical analytical method, this substrate enabled direct and convenient detection of DPP-IV in complex biofluids, including whole blood samples. In these assays, DPP-IV selectively hydrolyzed DPPLPOH, which underwent a self-immolative reaction to generate a masked electrochemically sensitive amino ferrocene reporter (AFOH). This electrochemical analytical tool demonstrated excellent sensing performance, characterized by exceptional enzyme binding properties. DPPLPOH showed excellent sensitivity and selectivity, with a detection limit of 0.021 ng/mL and a broad linear detection range of 0.1-100 ng/mL. The probe was specific to DPP-IV without interference from other electroactive species, enzymes, or hydrolases. Furthermore, DPPLPOH enabled real-time monitoring of DPP-IV activity on tumor cell surfaces and direct tracking of DPP-IV concentration in whole blood without a tedious separation process. This method may be a valuable tool in the early detection of pancreatic and thyroid cancers and in post-treatment surveillance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dipeptidyl Peptidase 4Biosensing TechniquesElectrochemical TechniquesHumansLimit of DetectionFerrous CompoundsMetallocenesPancreatic Neoplasms

Stichwörter der Autor:innen

Circulating biomarkerDipeptidyl peptidase-IVPancreatic cancerRedox probeTumor cell surfaceWhole blood

Substanzen

Dipeptidyl Peptidase 4DPP4 protein, humanFerrous CompoundsMetallocenesferrocene

Autor:innen und Institutionen

  • Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei, 106, Taiwan, ROC; Institute of Biochemical and Biomedical Engineering, National Taipei University of Technology, Ta…
  • Department of Nanotechnology, State Research Institute Centre for Physical Sciences and Technology (FTMC), Sauletekio av. 3, 10257, Vilnius, Lithuania.
  • Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei, 106, Taiwan, ROC.
  • Department of Nanotechnology, State Research Institute Centre for Physical Sciences and Technology (FTMC), Sauletekio av. 3, 10257, Vilnius, Lithuania. Electronic address: inga.vilkonciene@ftmc.lt.

Förderung

  • National Taipei University of Technology
  • National Science and Technology Council

Zitieren

APA

Kumaragurubaran, N., Yun, H. P., Zinovicius, A., Huang, S. T., Arul, P., Lin, H. Y., Min-Shin, O., & Morkvenaite-Vilkonciene, I. (2025). Development of an activity-based ratiometric electrochemical substrate for measuring circulating dipeptidyl peptidase-IV/CD26 in whole blood samples. Biosensors and Bioelectronics, 283, 117538. https://doi.org/10.1016/j.bios.2025.117538

Vancouver

Kumaragurubaran N, Yun HP, Zinovicius A, Huang ST, Arul P, Lin HY, et al. Development of an activity-based ratiometric electrochemical substrate for measuring circulating dipeptidyl peptidase-IV/CD26 in whole blood samples. Biosensors and Bioelectronics. 2025;283:117538. doi:10.1016/j.bios.2025.117538

BibTeX
@article{Kumaragurubaran2025,
  author = {Kumaragurubaran, Namasivayam and Yun, Hou Po and Zinovicius, Antanas and Huang, Sheng-Tung and Arul, Ponnusamy and Lin, Hsin-Yi and Min-Shin, Ou and Morkvenaite-Vilkonciene, Inga},
  title = {Development of an activity-based ratiometric electrochemical substrate for measuring circulating dipeptidyl peptidase-IV/CD26 in whole blood samples},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  volume = {283},
  pages = {117538},
  doi = {10.1016/j.bios.2025.117538}
}
Kostenlos starten →