EUVIMEDEUVIMED entdecken
Crossref

A dual-Color closed bipolar electrochemiluminescence platform for visual simultaneous diagnosis of two pluripotency markers in cancer patients’ urine

Nastaran Arab, Morteza Hosseini, Guobao Xu, Niloufar Sadeghi, Hodjattallah Rabbani

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2025.117482 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Nastaran Arab und 4 weiteren Autor:innen. Beteiligte Einrichtung: Nanobiosensors Lab, Department of Nanobiotechnology and Biomimetics, School of Life Science Engineering, College of Interdisciplinary Science and Tec…. Hauptthemen laut MEDLINE: Biosensing Techniques, Luminescent Measurements, Neoplasms, Nanog Homeobox Protein. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 59 Literaturangaben. Gefördert von: University of Tehran, Iran National Science Foundation, Chinese Academy of Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Here, for the first time, we introduce a simple yet effective one-step visual approach for the concurrent detection of octamer-binding transcription factor 4 (Oct-4) and Nanog, two pivotal homeobox genes involved in regulating pluripotency in both stem cells and certain cancer cells, within human urine samples. We utilized a closed bipolar electrochemistry system to enable the electrochemiluminescence (ECL) detection of pluripotency biomarkers. This was accomplished by capturing the ECL of Ru(bpy)32+ loaded into mesoporous SiO2 nanoparticles and luminol incorporated into luminol@MIL-53 on the upper and lower anodic poles of BPEs in separate chambers of a bipolar cell using a digital camera. An identical electric potential was applied across the bipolar electrodes, driving the reduction of thionine acetate at the cathodic poles and thereby facilitating simultaneous light emission of the luminophores. Moreover, the incorporation of electroactive Ti3C2Tx MXene-TiO2 nanosheets catalyzed the electro-oxidation of co-reactants within both the Ru(bpy)32+/TPrA and luminol/H2O2 systems, thereby enhancing the signal-to-background ratio and eliciting a significantly amplified visual ECL response. Under optimized conditions, the immunosensor displayed a linear response across a broad range of 100 pg mL-1 to 400 ng/mL for Nanog, with a detection limit of 21.58 pg mL-1, and a linear response from 200 pg mL-1 to 400 ng/mL with a detection limit of 106.24 pg mL-1 for Oct-4. This study supports the immunosensor's potential for broader clinical application, where its high specificity and sensitivity could offer significant benefits in cancer diagnostics and stem cell research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesLuminescent MeasurementsNeoplasmsNanog Homeobox ProteinOctamer Transcription Factor-3Biomarkers, TumorHumansElectrochemical TechniquesLuminolLimit of DetectionSilicon DioxideNanoparticles

Stichwörter der Autor:innen

2D nanomaterialsCancer stem cellCo-reactant acceleratorElectrochemiluminescenceImmunoassay

Substanzen

Nanog Homeobox ProteinOctamer Transcription Factor-3Biomarkers, TumorNANOG protein, humanLuminolPOU5F1 protein, humanSilicon Dioxide

Autor:innen und Institutionen

  • Nanobiosensors Lab, Department of Nanobiotechnology and Biomimetics, School of Life Science Engineering, College of Interdisciplinary Science and Technology, University of Tehran, Tehran, Iran.
  • Nanobiosensors Lab, Department of Nanobiotechnology and Biomimetics, School of Life Science Engineering, College of Interdisciplinary Science and Technology, University of Tehran, Tehran, Iran; State Key Laboratory of E…
  • State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, China; School of Applied Chemistry and Engineering, University of Science an…
  • Antigen Antibody Engineering Department, Institute of Medical Biotechnology (IMB), National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran, Iran.
  • Antigen Antibody Engineering Department, Institute of Medical Biotechnology (IMB), National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran, Iran; Monoclonal Antibody Research Center, Avicenna Researc…

Förderung

  • University of Tehran
  • Iran National Science Foundation
  • Chinese Academy of Sciences
  • National Natural Science Foundation of China
  • National Institute for Genetic Engineering and Biotechnology

Zitieren

APA

Arab, N., Hosseini, M., Xu, G., Sadeghi, N., & Rabbani, H. (2025). A dual-Color closed bipolar electrochemiluminescence platform for visual simultaneous diagnosis of two pluripotency markers in cancer patients’ urine. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117482

Vancouver

Arab N, Hosseini M, Xu G, Sadeghi N, Rabbani H. A dual-Color closed bipolar electrochemiluminescence platform for visual simultaneous diagnosis of two pluripotency markers in cancer patients’ urine. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117482

BibTeX
@article{Arab2025,
  author = {Arab, Nastaran and Hosseini, Morteza and Xu, Guobao and Sadeghi, Niloufar and Rabbani, Hodjattallah},
  title = {A dual-Color closed bipolar electrochemiluminescence platform for visual simultaneous diagnosis of two pluripotency markers in cancer patients’ urine},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117482}
}
Kostenlos starten →