EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Troponin I biomarker sensing from clinical patient samples using molecularly imprinted polymer nanoparticles for advancing healthcare approaches in cardiovascular disease

Joshua Saczek, Oliver Jamieson, Jake McClements, Amy Dann, Rhiannon E Johnson, Alexander D Stokes, Robert D Crapnell, Craig E Banks, Francesco Canfarotta, Ioakim Spyridopoulos, Alan Thomson, Azfar Zaman und 2 weitere

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2025.117467 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Joshua Saczek und 13 weiteren Autor:innen. Beteiligte Einrichtung: Newcastle University, School of Engineering, Merz Court, Claremont Road, NE1 7RU, Newcastle Upon Tyne, UK; School of Engineering, Engineering A build…. Hauptthemen laut MEDLINE: Troponin I, Biosensing Techniques, Nanoparticles, Myocardial Infarction. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 79 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council, UK Research and Innovation Medical Research Council, Rosetrees.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiac troponin I (cTnI) is a critical protein biomarker for heart attack diagnosis. This study presents a thorough analysis of a novel biosensing device utilizing molecularly imprinted polymer nanoparticles (nanoMIPs) for detecting cTnI in clinical patient serum samples post myocardial infarction. The methodology, based on the heat-transfer method approach, offers faster measurements times than the current gold standard and sample volumes equivalent to a single blood drop. Biomarker binding shows performance comparable to a high-sensitivity ELISA, accurately identifying patients with elevated cTnI levels (R2 = 0.893). The cTnI peak concentration time variations are attributed to heterogeneous serum complexes, with different troponin complex sizes potentially generating differing thermal insulation levels. Comparison with an established patient database demonstrates robust correlations between our cTnI concentrations and clinical parameters (R2 = 0.855). This underscores the potential of nanoMIP sensors for sensitive cTnI detection, providing insights into post-heart attack biomarker levels. Furthermore, our methodology presents the additional benefits of being low cost and portable enabling measurements at time and place of patients. Consequently, it holds the potential to become a vital part of the diagnostic pathway for heart attack treatment, ultimately reducing healthcare costs and improving patient outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin IBiosensing TechniquesNanoparticlesMyocardial InfarctionMolecularly Imprinted PolymersHumansBiomarkersMolecular ImprintingPolymers

Stichwörter der Autor:innen

BiosensorsCardiovascular diseaseMolecularly imprinted polymer nanoparticles (NanoMIPs)Myocardial infarctionTroponin I (cTnI)

Substanzen

Troponin IBiomarkersMolecularly Imprinted PolymersPolymers

Autor:innen und Institutionen

  • Newcastle University, School of Engineering, Merz Court, Claremont Road, NE1 7RU, Newcastle Upon Tyne, UK; School of Engineering, Engineering A building, East Booth Street, University of Manchester, M13 9QS, Manchester,…
  • Newcastle University, School of Engineering, Merz Court, Claremont Road, NE1 7RU, Newcastle Upon Tyne, UK.
  • MIP Discovery Ltd, The Exchange Building, Colworth Park, Sharnbrook, MK44 1LQ, Bedford, UK.
  • Manchester Metropolitan University, Faculty of Science and Engineering, Chester Street, M1 5GD, Manchester, UK.
  • Department of Cardiology, Freeman Hospital and Newcastle University, Translational and Clinical Research Institute, NE7 7DN, Newcastle upon Tyne, UK.

Förderung

  • Engineering and Physical Sciences Research Council
  • UK Research and Innovation Medical Research Council
  • Rosetrees
  • National Institute of Food and Agriculture

Zitieren

APA

Saczek, J., Jamieson, O., McClements, J., Dann, A., Johnson, R. E., Stokes, A. D., Crapnell, R. D., Banks, C. E., Canfarotta, F., Spyridopoulos, I., Thomson, A., Zaman, A., Novakovic, K., & Peeters, M. (2025). Troponin I biomarker sensing from clinical patient samples using molecularly imprinted polymer nanoparticles for advancing healthcare approaches in cardiovascular disease. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117467

Vancouver

Saczek J, Jamieson O, McClements J, Dann A, Johnson RE, Stokes AD, et al. Troponin I biomarker sensing from clinical patient samples using molecularly imprinted polymer nanoparticles for advancing healthcare approaches in cardiovascular disease. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117467

BibTeX
@article{Saczek2025,
  author = {Saczek, Joshua and Jamieson, Oliver and McClements, Jake and Dann, Amy and Johnson, Rhiannon E and Stokes, Alexander D and Crapnell, Robert D and Banks, Craig E and Canfarotta, Francesco and Spyridopoulos, Ioakim and Thomson, Alan and Zaman, Azfar and Novakovic, Katarina and Peeters, Marloes},
  title = {Troponin I biomarker sensing from clinical patient samples using molecularly imprinted polymer nanoparticles for advancing healthcare approaches in cardiovascular disease},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117467}
}
Kostenlos starten →