Using signal off-to-on strategy for designing precise and ultrasensitive biosensor towards hepatocellular carcinoma through protein variant detection based on biocompatible bimetallic MOF
Biosensors and Bioelectronics · 2025-07 · 280 · 117429
DOI: 10.1016/j.bios.2025.117429 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-07. Verfasst von Wenwen Tu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Collaborative Innovation Centre of Biomedical Functional Materials of Jiangsu Province, School of Chemistry and Materials Science, Nanjing Normal Uni…. Hauptthemen laut MEDLINE: Biosensing Techniques, Carcinoma, Hepatocellular, Liver Neoplasms, Metal-Organic Frameworks. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: Jiangsu Province Natural Science Foundation, National Natural Science Foundation of China.
Abstract (Originalsprache)
The high mortality rate of patients with hepatocellular carcinoma (HCC) is an ever-increasing worldwide concern. Fortunately, the newest research has found that the proportion of a protein variant in total alpha-fetoprotein (AFP) over 10 % can accurately predict the incidence of HCC. Therefore, a signal off-to-on strategy was designed for developing a novel precise and ultrasensitive biosensor towards HCC through protein variant detection based on bimetallic metal-organic framework (MOF). In this study, the biocompatible Fe2Ni-MOF was used as an electrochemically immobilized carrier, which provided abundant active sites and exhibited a synergistic effect between Fe and Ni ions for dramatically promoting the electron transfer and improving the electrochemical reduction efficiency, prominently facilitating signal amplification of the biosensing platform. Then, we designed a novel ordered labeling method to distinguish AFP-L3 from overall AFP and introduced a signal off-to-on strategy for achieving highly efficient determination of AFP-L3 %. This proposed biosensor demonstrated a satisfactory linear range, along with a very low detection limit of 69 pg/mL for AFP-L3, which was far below the medically relevant threshold level. Furthermore, the adopted biosensor presented preeminent specificity, and favorable reproducibility.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Collaborative Innovation Centre of Biomedical Functional Materials of Jiangsu Province, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, PR China.
- Collaborative Innovation Centre of Biomedical Functional Materials of Jiangsu Province, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, PR China; School of Chemistry and Molecular…
Förderung
- Jiangsu Province Natural Science Foundation
- National Natural Science Foundation of China
Zitieren
APA
Tu, W., Liu, H., Wang, J., Wang, Y., Wang, Z., & Dai, Z. (2025). Using signal off-to-on strategy for designing precise and ultrasensitive biosensor towards hepatocellular carcinoma through protein variant detection based on biocompatible bimetallic MOF. Biosensors and Bioelectronics, 280, 117429. https://doi.org/10.1016/j.bios.2025.117429
Vancouver
Tu W, Liu H, Wang J, Wang Y, Wang Z, Dai Z. Using signal off-to-on strategy for designing precise and ultrasensitive biosensor towards hepatocellular carcinoma through protein variant detection based on biocompatible bimetallic MOF. Biosensors and Bioelectronics. 2025;280:117429. doi:10.1016/j.bios.2025.117429
BibTeX
@article{Tu2025,
author = {Tu, Wenwen and Liu, Hua and Wang, Junfei and Wang, Yu and Wang, Zhaoyin and Dai, Zhihui},
title = {Using signal off-to-on strategy for designing precise and ultrasensitive biosensor towards hepatocellular carcinoma through protein variant detection based on biocompatible bimetallic MOF},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {280},
pages = {117429},
doi = {10.1016/j.bios.2025.117429}
}
EUVIMED