EUVIMEDEUVIMED entdecken
Crossref

Using signal off-to-on strategy for designing precise and ultrasensitive biosensor towards hepatocellular carcinoma through protein variant detection based on biocompatible bimetallic MOF

Wenwen Tu, Hua Liu, Junfei Wang, Yu Wang, Zhaoyin Wang, Zhihui Dai

Biosensors and Bioelectronics · 2025-07 · 280 · 117429

DOI: 10.1016/j.bios.2025.117429 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-07. Verfasst von Wenwen Tu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Collaborative Innovation Centre of Biomedical Functional Materials of Jiangsu Province, School of Chemistry and Materials Science, Nanjing Normal Uni…. Hauptthemen laut MEDLINE: Biosensing Techniques, Carcinoma, Hepatocellular, Liver Neoplasms, Metal-Organic Frameworks. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: Jiangsu Province Natural Science Foundation, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The high mortality rate of patients with hepatocellular carcinoma (HCC) is an ever-increasing worldwide concern. Fortunately, the newest research has found that the proportion of a protein variant in total alpha-fetoprotein (AFP) over 10 % can accurately predict the incidence of HCC. Therefore, a signal off-to-on strategy was designed for developing a novel precise and ultrasensitive biosensor towards HCC through protein variant detection based on bimetallic metal-organic framework (MOF). In this study, the biocompatible Fe2Ni-MOF was used as an electrochemically immobilized carrier, which provided abundant active sites and exhibited a synergistic effect between Fe and Ni ions for dramatically promoting the electron transfer and improving the electrochemical reduction efficiency, prominently facilitating signal amplification of the biosensing platform. Then, we designed a novel ordered labeling method to distinguish AFP-L3 from overall AFP and introduced a signal off-to-on strategy for achieving highly efficient determination of AFP-L3 %. This proposed biosensor demonstrated a satisfactory linear range, along with a very low detection limit of 69 pg/mL for AFP-L3, which was far below the medically relevant threshold level. Furthermore, the adopted biosensor presented preeminent specificity, and favorable reproducibility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesCarcinoma, HepatocellularLiver NeoplasmsMetal-Organic Frameworksalpha-FetoproteinsHumansLimit of DetectionElectrochemical TechniquesNickelIronReproducibility of Results

Stichwörter der Autor:innen

AFP-L3BiosensorHepatocellular carcinomaPrecise assaySignal amplification

Substanzen

Metal-Organic Frameworksalpha-FetoproteinsNickelIronAFP protein, human

Autor:innen und Institutionen

  • Collaborative Innovation Centre of Biomedical Functional Materials of Jiangsu Province, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, PR China.
  • Collaborative Innovation Centre of Biomedical Functional Materials of Jiangsu Province, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, 210023, PR China; School of Chemistry and Molecular…

Förderung

  • Jiangsu Province Natural Science Foundation
  • National Natural Science Foundation of China

Zitieren

APA

Tu, W., Liu, H., Wang, J., Wang, Y., Wang, Z., & Dai, Z. (2025). Using signal off-to-on strategy for designing precise and ultrasensitive biosensor towards hepatocellular carcinoma through protein variant detection based on biocompatible bimetallic MOF. Biosensors and Bioelectronics, 280, 117429. https://doi.org/10.1016/j.bios.2025.117429

Vancouver

Tu W, Liu H, Wang J, Wang Y, Wang Z, Dai Z. Using signal off-to-on strategy for designing precise and ultrasensitive biosensor towards hepatocellular carcinoma through protein variant detection based on biocompatible bimetallic MOF. Biosensors and Bioelectronics. 2025;280:117429. doi:10.1016/j.bios.2025.117429

BibTeX
@article{Tu2025,
  author = {Tu, Wenwen and Liu, Hua and Wang, Junfei and Wang, Yu and Wang, Zhaoyin and Dai, Zhihui},
  title = {Using signal off-to-on strategy for designing precise and ultrasensitive biosensor towards hepatocellular carcinoma through protein variant detection based on biocompatible bimetallic MOF},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  volume = {280},
  pages = {117429},
  doi = {10.1016/j.bios.2025.117429}
}
Kostenlos starten →