A colorimetric and photocurrent-polarity-switching photoelectrochemical dual-mode biosensor for the ultrasensitive detection of DNA damage biomarker and rapid screening of genotoxic chemicals
Biosensors and Bioelectronics · 2025-07 · 279 · 117396
DOI: 10.1016/j.bios.2025.117396 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-07. Verfasst von Bihong Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Energy Environment and Safety Engineering & College of Carbon Metrology, China Jiliang University, Hangzhou, Zhejiang, 310018, PR China. E…. Hauptthemen laut MEDLINE: Biosensing Techniques, Colorimetry, DNA Damage, Histones. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Phosphorylated histone H2AX (γH2AX), an early sensitive biomarker for DNA damage and a key indicator of genotoxicity, has been reliably used to screen for genotoxic chemicals. However, developing a sensitive and visual method for detecting γH2AX in cells, especially through a switchable dual-mode detection system using a multifunctional sensing material, remains a significant challenge. Herein, a dual-mode sensing platform was constructed for γH2AX detection, utilizing a novel multifunctional Bi-doped Bi2MoO6 (Bi/Bi2MoO6)-powered colorimetric (CL) and photocurrent-polarity-switching photoelectrochemical (PEC) system. Thanks to Bi doping, Bi/Bi2MoO6 exhibited excellent peroxidase-like activity and photocatalytic properties, allowing it to simultaneously satisfy H2O2-mediated CL-PEC dual-mode sensing. Based on the γH2AX-associated sandwich immunoreaction and glucose oxidase catalysis reaction in the microplates, the signaling factor H2O2 was obtained. Afterward, H2O2 was transferred to the catalytic system containing Bi/Bi2MoO6 and TMB to obtain visual γH2AX detection, with a low detection limit of 70.8 fg/mL. Meanwhile, H2O2 effectively switched the photocurrent polarity of the ITO/Bi/Bi2MoO6 from anode to cathode due to their well-matched potentials, thus leading to the highly sensitive and selective PEC assay of γH2AX, with an ultralow detection limit of 0.32 fg/mL. This is 20,000 times lower than the reported best detection performance (6.78 pg/mL), significantly ensuring the ultrasensitive detection of low-abundance γH2AX and accurate chemical toxicity screening. Additionally, this sensor showed good practicability in cells exposed to known genotoxic chemicals. Finally, using our constructed sensor, four emerging pollutants, including PFOA, PFOS, OBS, and PFAN, were quickly screened to identify potential genotoxicity. Surprisingly, PFOA exhibited the strongest toxic effects, which is a significant finding that enables us to anchor PFOA for further toxicity mechanism studies. In short, this work provides a convenient, rapid, reliable and accurate genotoxicity screening tool for chemicals.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Energy Environment and Safety Engineering & College of Carbon Metrology, China Jiliang University, Hangzhou, Zhejiang, 310018, PR China. Electronic address: bhzhang@cjlu.edu.cn.
- College of Life Sciences, China Jiliang University, Hangzhou, Zhejiang, 310016, PR China.
- College of Energy Environment and Safety Engineering & College of Carbon Metrology, China Jiliang University, Hangzhou, Zhejiang, 310018, PR China.
- College of Energy Environment and Safety Engineering & College of Carbon Metrology, China Jiliang University, Hangzhou, Zhejiang, 310018, PR China; Hangzhou Institute of Medicine, Chinese Academy of Sciences, Hangzhou,…
- College of Energy Environment and Safety Engineering & College of Carbon Metrology, China Jiliang University, Hangzhou, Zhejiang, 310018, PR China; School of Environment, Hangzhou Institute for Advanced Study, Universit…
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Zhang, B., Jian, X., An, Z., Yang, X., Chen, H., Lu, C., Li, M., & Guo, L. H. (2025). A colorimetric and photocurrent-polarity-switching photoelectrochemical dual-mode biosensor for the ultrasensitive detection of DNA damage biomarker and rapid screening of genotoxic chemicals. Biosensors and Bioelectronics, 279, 117396. https://doi.org/10.1016/j.bios.2025.117396
Vancouver
Zhang B, Jian X, An Z, Yang X, Chen H, Lu C, et al. A colorimetric and photocurrent-polarity-switching photoelectrochemical dual-mode biosensor for the ultrasensitive detection of DNA damage biomarker and rapid screening of genotoxic chemicals. Biosensors and Bioelectronics. 2025;279:117396. doi:10.1016/j.bios.2025.117396
BibTeX
@article{Zhang2025,
author = {Zhang, Bihong and Jian, Xiaoyu and An, Zhiquan and Yang, Xiaotian and Chen, Hongjie and Lu, Chenze and Li, Minjie and Guo, Liang-Hong},
title = {A colorimetric and photocurrent-polarity-switching photoelectrochemical dual-mode biosensor for the ultrasensitive detection of DNA damage biomarker and rapid screening of genotoxic chemicals},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {279},
pages = {117396},
doi = {10.1016/j.bios.2025.117396}
}
EUVIMED