EUVIMEDEUVIMED entdecken
Crossref

Ratiometric electrochemiluminescence biosensor based on red blood cell membrane as an efficient antifouling interface for ultrasensitive analysis of circulating tumor cells in human serum

Qiongwei Wu, Fan Geng, Chengcheng Liu, Jia Wang, Xianzhen Song, Caifeng Ding

Biosensors and Bioelectronics · 2025-06 · 278 · 117358

DOI: 10.1016/j.bios.2025.117358 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-06. Verfasst von Qiongwei Wu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, Shandong Key Laboratory of Biochemical Ana…. Hauptthemen laut MEDLINE: Biosensing Techniques, Neoplastic Cells, Circulating, Luminescent Measurements, Electrochemical Techniques. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: Major Scientific and Technological Innovation Project of Shandong Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemiluminescence (ECL) biosensors are suitable for trace detection of serum biomarkers due to their high sensitivity and rapid response. However, human serum contains many interfering biomolecules that affect the output signals and operating life of biosensors. On this basis, a highly bioactive ECL sensing platform based on red blood cell membrane (RBCM) as an antifouling interface was developed for sensitive and accurate detection of circulating tumor cells (CTCs). Specifically, RBCM exhibited excellent antifouling performance due to its superhydrophilicity and low content of membrane proteins, and its good biocompatibility avoided the adverse effects of chemical antifouling coatings on the activity of biosensors. At the same time, the electropolymerized polyaniline nanowires (PANI NWs) were inserted into RBCM, which enhanced its stability and conductivity, thus expanding the potential application of antifouling cell membranes in ECL analysis. In addition, C3N4 was modified as an internal standard to eliminate background signals and external interferences, thereby improving detection accuracy. According to these strategies, the constructed ECL antifouling biosensor achieved ultrasensitive CTCs detection in human serum, with a wide linear range (10-5 × 106 cells mL-1) and a detection limit as low as 3 cells mL-1 (3δ/k). This study provides positive insights for bioanalysis application of antifouling cell membranes and trace detection of serum biomarkers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesNeoplastic Cells, CirculatingLuminescent MeasurementsElectrochemical TechniquesErythrocyte MembraneHumansNanowiresLimit of DetectionAniline Compounds

Stichwörter der Autor:innen

Antifouling interfaceBiosensorElectrochemiluminescenceInternal standardRed blood cell membrane

Substanzen

polyanilineAniline Compounds

Autor:innen und Institutionen

  • Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Univ…

Förderung

  • Major Scientific and Technological Innovation Project of Shandong Province
  • National Natural Science Foundation of China

Zitieren

APA

Wu, Q., Geng, F., Liu, C., Wang, J., Song, X., & Ding, C. (2025). Ratiometric electrochemiluminescence biosensor based on red blood cell membrane as an efficient antifouling interface for ultrasensitive analysis of circulating tumor cells in human serum. Biosensors and Bioelectronics, 278, 117358. https://doi.org/10.1016/j.bios.2025.117358

Vancouver

Wu Q, Geng F, Liu C, Wang J, Song X, Ding C. Ratiometric electrochemiluminescence biosensor based on red blood cell membrane as an efficient antifouling interface for ultrasensitive analysis of circulating tumor cells in human serum. Biosensors and Bioelectronics. 2025;278:117358. doi:10.1016/j.bios.2025.117358

BibTeX
@article{Wu2025,
  author = {Wu, Qiongwei and Geng, Fan and Liu, Chengcheng and Wang, Jia and Song, Xianzhen and Ding, Caifeng},
  title = {Ratiometric electrochemiluminescence biosensor based on red blood cell membrane as an efficient antifouling interface for ultrasensitive analysis of circulating tumor cells in human serum},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  volume = {278},
  pages = {117358},
  doi = {10.1016/j.bios.2025.117358}
}
Kostenlos starten →