Ratiometric fluorescence sensor based on bimetallic organic frameworks for anthrax biomarker detection
Biosensors and Bioelectronics · 2025-06 · 278 · 117279
DOI: 10.1016/j.bios.2025.117279 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-06. Verfasst von Limin Zheng und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211198, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Metal-Organic Frameworks, Anthrax, Bacillus anthracis. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
It is of great significance to construct ratiometric fluorescence sensors with simple operation and desirable anti-interference ability. In this study, a bimetallic organic framework was prepared for the first time by a one-pot solvothermal method, using 4,4'-biphenyl dicarboxylic acid as ligand, lanthanide metal terbium ions (Tb3+) and transition metal zirconium ions (Zr4+) as central metal ions. This preparation method was easy to carry out. On this basis, a novel ratiometric fluorescence sensor Tb-Zr-MOF was constructed successfully for the detection of anthrax biomarker (2,6-pyridinedicarboxylic acid (DPA)). When DPA was added into the detection system, the fluorescence of Tb3+ was enhanced due to the energy transfer from DPA to Tb3+. Therefore, under the single excitation at 285 nm, the fluorescence emission intensity of Tb-Zr-MOF at 402 nm remained unchanged and the fluorescence emission intensity at 546 nm increased. As a ratiometric fluorescence sensor, Tb-Zr-MOF showed good linear response to DPA in the range of 5∼100 μM and the limit of detection was 1.72 μM. This sensor reduces the interference of environmental factors and achieves high sensitivity detection, which is superior to the traditional single emission peak fluorescence sensor. In addition, the developed Tb-Zr-MOF sensor was used to detect DPA in Bauhinia bark samples successfully. The recovery rate was 98.80%∼104.8%, which proved the practical application of Tb-Zr-MOF in complex environment. It is expected to provide a reliable method for the detection of biomarkers of Bacillus anthracis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211198, China.
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211198, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, China Pharmaceutical University, Nanjing,…
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Zheng, L., Zhang, J., Gao, J., He, F., Yang, S., He, H., Dramou, P., & Xiao, D. (2025). Ratiometric fluorescence sensor based on bimetallic organic frameworks for anthrax biomarker detection. Biosensors and Bioelectronics, 278, 117279. https://doi.org/10.1016/j.bios.2025.117279
Vancouver
Zheng L, Zhang J, Gao J, He F, Yang S, He H, et al. Ratiometric fluorescence sensor based on bimetallic organic frameworks for anthrax biomarker detection. Biosensors and Bioelectronics. 2025;278:117279. doi:10.1016/j.bios.2025.117279
BibTeX
@article{Zheng2025,
author = {Zheng, Limin and Zhang, Jiarong and Gao, Jie and He, Fusheng and Yang, Siqian and He, Hua and Dramou, Pierre and Xiao, Deli},
title = {Ratiometric fluorescence sensor based on bimetallic organic frameworks for anthrax biomarker detection},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {278},
pages = {117279},
doi = {10.1016/j.bios.2025.117279}
}
EUVIMED