EUVIMEDEUVIMED entdecken
Crossref

Enhanced piezoelectric sensor to distinguish real-time arrhythmia for predicting heart failure

Tao Jing, Yaolei Zhang, Zhongtao Li, Xinyu Tao, Xiong Xiong, Chaoming Xie, Weili Deng, Feng Lin, Hongyu Sun, Shuxin Qu

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2025.117148 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Tao Jing und 9 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Engineering, College of Medicine, Southwest Jiaotong University, Chengdu, 610031, Sichuan, PR China; Key Laboratory of Advanc…. Hauptthemen laut MEDLINE: Heart Failure, Biosensing Techniques, Arrhythmias, Cardiac. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, Chengdu Science and Technology Program, Chinese PLA General Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Monitoring cardiac rhythm is crucial for diagnosis of heart failure. However, the deficient sensitivity of polyvinylidene fluoride (PVDF) sensors impede their application in monitoring of cardiac rhythm due to the limited piezoelectricity. Here, doping of CoFe2O4 and aligning fibers were jointly adopted to enhance the piezoelectricity of PVDF, attributed to the transformation of α-PVDF to β-PVDF from 51.54 to 82.36 % confirmed by FTIR and First Principles simulation. Then the higher sensitivity piezoelectric sensors were developed based on aligned PVDF/CoFe2O4 accompanying with the superior frequency characteristics, rapid response, endurance stability, permeability and self-cleaning capabilities, compared to that of random PVDF/CoFe2O4 and PVDF sensors, which were 17.28, 13.40 and 2.16 mV kPa -1, respectively. Thus, the sensitivity of PVDF/CoFe2O4 sensors was sufficient to distinguish the variations of cardiac rhythm or arrhythmia of the established and verified heart failure rat model, including amplitude, cycle and frequency. The notable characteristic of an evolving heart failure was the significantly decreased amplitude initially, followed by a dramatic drop in the cycles of cardiac impulse. Hence, this non-invasive method is promise in providing valuable warning signs for predicting heart failure based on aligned PVDF/CoFe2O4 sensors, as well as in the prevention its occurrence.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart FailureBiosensing TechniquesArrhythmias, CardiacAnimalsPolyvinylsRatsCobaltEquipment DesignHumansMaleFluorocarbon Polymers

Stichwörter der Autor:innen

Cardiac rhythm monitoringHeart failurePiezoelectric filmSensor

Substanzen

polyvinylidene fluoridePolyvinylsCobaltFluorocarbon Polymers

Autor:innen und Institutionen

  • Institute of Biomedical Engineering, College of Medicine, Southwest Jiaotong University, Chengdu, 610031, Sichuan, PR China; Key Laboratory of Advanced Technologies of Materials Ministry of Education, School of Material…
  • Institute of Biomedical Engineering, College of Medicine, Southwest Jiaotong University, Chengdu, 610031, Sichuan, PR China.
  • School of Life Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, Sichuan, PR China.
  • Key Laboratory of Advanced Technologies of Materials Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, PR China.
  • Department of Thoracic Surgery, West China Hospital, Chengdu, 610031, Sichuan, PR China.
  • Institute of Biomedical Engineering, College of Medicine, Southwest Jiaotong University, Chengdu, 610031, Sichuan, PR China; Clinical Biobank Center, General Hospital of Western Theater Command, Chengdu, 610031, Sichuan…

Förderung

  • Fundamental Research Funds for the Central Universities
  • Chengdu Science and Technology Program
  • Chinese PLA General Hospital
  • Science and Technology Department of Sichuan Province

Zitieren

APA

Jing, T., Zhang, Y., Li, Z., Tao, X., Xiong, X., Xie, C., Deng, W., Lin, F., Sun, H., & Qu, S. (2025). Enhanced piezoelectric sensor to distinguish real-time arrhythmia for predicting heart failure. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117148

Vancouver

Jing T, Zhang Y, Li Z, Tao X, Xiong X, Xie C, et al. Enhanced piezoelectric sensor to distinguish real-time arrhythmia for predicting heart failure. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117148

BibTeX
@article{Jing2025,
  author = {Jing, Tao and Zhang, Yaolei and Li, Zhongtao and Tao, Xinyu and Xiong, Xiong and Xie, Chaoming and Deng, Weili and Lin, Feng and Sun, Hongyu and Qu, Shuxin},
  title = {Enhanced piezoelectric sensor to distinguish real-time arrhythmia for predicting heart failure},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2025.117148}
}
Kostenlos starten →