Gold metallene-based ECL biosensor to detect miRNA-126 for coronary artery calcification diagnosis
Biosensors and Bioelectronics · 2025
DOI: 10.1016/j.bios.2024.116993 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Fengwen Cui und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, China-Japan Union Hospital of Jilin University, Changchun, 130033, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Gold, MicroRNAs, Metal Nanoparticles. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
Coronary artery calcification (CAC) is a pathological change and independent risk factor in cardiovascular diseases. In this work, a gold-based metallene structure was prepared as sensing interface based on mPEG-SH modified Au nanoparticles for the CAC detection. Firstly, a novel nanovesicle was self-assembled with excellent conductivity. The nanovesicles can confine copper nanoclusters and restrict the intramolecular rotation and vibration of copper nanoclusters. So, the luminescence nanovesicle-based confined-induced electrochemiluminescence (ECL) nanoprobe was prepared. Secondly, a novel Au metallene material was constructed by thermally treating the mPEG-SH modified Au NPs. The disulfide bonds provided a stable cross-linked network of Au nanoparticles to form Au metallene with exceptional electron transfer capacity and abundant active sites, which significantly enhanced the ECL intensity of luminescence nanovesicle. Finally, the sensing system was established with DNA catalytic hairpin assembly technology to detect miR-126-3p in the CAC patients' plasma. Combining with the vascular calcification scores obtained from intravenous ultrasound during interventions, the results showed that miR-126-3p can be used as a biomarker for diagnosing CAC lesions. Moreover, the constructed biosensing system had a better AUC value (0.967) over that of the classical PCR method. This Au metallene-based ECL sensor provided an inspiring plasma sample detection strategy for the early screening and auxiliary diagnosis of CAC patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, China-Japan Union Hospital of Jilin University, Changchun, 130033, China.
- Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China.
- Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun, 130012, China. Electronic address: qma@jlu.edu.cn.
- Department of Laboratory Medicine Center, China-Japan Union Hospital of Jilin University, Changchun, 130033, China. Electronic address: shijingwei@jlu.edu.cn.
- Department of Cardiovascular Medicine, China-Japan Union Hospital of Jilin University, Changchun, 130033, China. Electronic address: heyq@jlu.edu.cn.
Zitieren
APA
Cui, F., Chen, W., Wang, P., Fan, J., Si, D., Ma, Q., Shi, J., & He, Y. (2025). Gold metallene-based ECL biosensor to detect miRNA-126 for coronary artery calcification diagnosis. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116993
Vancouver
Cui F, Chen W, Wang P, Fan J, Si D, Ma Q, et al. Gold metallene-based ECL biosensor to detect miRNA-126 for coronary artery calcification diagnosis. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2024.116993
BibTeX
@article{Cui2025,
author = {Cui, Fengwen and Chen, Weiwei and Wang, Peilin and Fan, Jiwen and Si, Daoyuan and Ma, Qiang and Shi, Jingwei and He, Yuquan},
title = {Gold metallene-based ECL biosensor to detect miRNA-126 for coronary artery calcification diagnosis},
journal = {Biosensors and Bioelectronics},
year = {2025},
doi = {10.1016/j.bios.2024.116993}
}
EUVIMED