EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Structured protein probes modified with selenium nanoparticle for 1-minute measurement of SARS-CoV-2 antigen

Chunxia Chen, Shujie Duan, Jianing Ji, Mengli Wu, Zhan Yang, Mengyang Cai, Menghan Xue, Lanju Wang, Rui Chen, Sima Yaron, Keying Guo, Sergio Benardini und 2 weitere

Biosensors and Bioelectronics · 2025-01 · 268 · 116878

DOI: 10.1016/j.bios.2024.116878 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-01. Verfasst von Chunxia Chen und 13 weiteren Autor:innen. Beteiligte Einrichtung: Joint National Laboratory for Antibody Drug Engineering, Clinical Laboratory of the First Affiliated Hospital, School of Medicine, Henan University, …. Hauptthemen laut MEDLINE: SARS-CoV-2, COVID-19, Selenium, Biosensing Techniques. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key Technologies Research and Development Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional point-of-care lateral flow immunoassays are characterized by an antibody-tagged probe irregular coupling that can limit sensitivity and require a long assay's time. We synthesized polyethylene glycol-modified selenium nanoparticles (PEG-SeNPs) by template method and developed a strategy to set antibody probes targeted and orderly by using PEG-SeNPs. Synthesized PEG-SeNPs with high stability could immobilize antibodies in the "stand-up" orientation, resulting in a faster detection time of less than 1 min by direct observer visualization without instruments or equipment. Results showed that SARS-CoV-2 antibody could be systematically structured on the chip, resulting in a detection limit of 10 pg/mL, significantly higher than conventional chips. The new device has been validated on 192 clinical samples and we found 100% negative coincidence, 93.94% positive coincidence, and 95.83% overall coincidence with reverse transcriptional PCR test. The orderly arrayed probe's stability allowed to detect throat swabs, saliva, serum, fingertip blood samples, and mutant strains without cross-reactivity with common respiratory viruses or pathogenic strains, demonstrating promising potential for a universal colorimetric platform for ultrafast field-deployable diagnostics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SARS-CoV-2COVID-19SeleniumBiosensing TechniquesAntigens, ViralNanoparticlesHumansImmunoassayLimit of DetectionAntibodies, ViralAntibodies, ImmobilizedCOVID-19 Serological TestingPolyethylene Glycols

Stichwörter der Autor:innen

DiagnosisLiquid biopsyPoint of care testSARS-CoV-2Selenium nanoparticle

Substanzen

SeleniumAntigens, ViralAntibodies, ViralAntibodies, ImmobilizedPolyethylene Glycols

Autor:innen und Institutionen

  • Joint National Laboratory for Antibody Drug Engineering, Clinical Laboratory of the First Affiliated Hospital, School of Medicine, Henan University, Kaifeng, 475004, People's Republic of China.
  • Joint National Laboratory for Antibody Drug Engineering, Clinical Laboratory of the First Affiliated Hospital, School of Medicine, Henan University, Kaifeng, 475004, People's Republic of China; Medical Laboratory Depart…
  • Department of Blood Transfusion, The Affiliated Cancer Hospital of Zhengzhou University & Henan Cancer Hospital, Zhengzhou, 450008, People's Republic of China.
  • Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing, 400016, People's Republic of China.
  • Faculty of Biotechnology and Food Engineering, Technion-Israel Institute of Technology (IIT), Haifa, 3200003, Israel.
  • Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, 3052, Australia; Guangdong Provincial Key Laboratory of Materials and Technologies for Energy Conversion (MATEC), Guangdong Technion-Israel Inst…

Förderung

  • Key Technologies Research and Development Program

Zitieren

APA

Chen, C., Duan, S., Ji, J., Wu, M., Yang, Z., Cai, M., Xue, M., Wang, L., Chen, R., Yaron, S., Guo, K., Benardini, S., Wang, Z., & Luo, Y. (2025). Structured protein probes modified with selenium nanoparticle for 1-minute measurement of SARS-CoV-2 antigen. Biosensors and Bioelectronics, 268, 116878. https://doi.org/10.1016/j.bios.2024.116878

Vancouver

Chen C, Duan S, Ji J, Wu M, Yang Z, Cai M, et al. Structured protein probes modified with selenium nanoparticle for 1-minute measurement of SARS-CoV-2 antigen. Biosensors and Bioelectronics. 2025;268:116878. doi:10.1016/j.bios.2024.116878

BibTeX
@article{Chen2025,
  author = {Chen, Chunxia and Duan, Shujie and Ji, Jianing and Wu, Mengli and Yang, Zhan and Cai, Mengyang and Xue, Menghan and Wang, Lanju and Chen, Rui and Yaron, Sima and Guo, Keying and Benardini, Sergio and Wang, Zhizeng and Luo, Yang},
  title = {Structured protein probes modified with selenium nanoparticle for 1-minute measurement of SARS-CoV-2 antigen},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  volume = {268},
  pages = {116878},
  doi = {10.1016/j.bios.2024.116878}
}
Kostenlos starten →