EUVIMEDEUVIMED entdecken
Crossref

Benchtop to at-home test: Amplicon-depleted CRISPR-regulated loop mediated amplification at skin-temperature for viral load monitoring

Yumeng Cao, Haosi Lin, Xiao Lu, Xiaolong Wu, Yuxuan Zhu, Zibin Zhao, Yanan Li, Samantha Borje, Grace C Y Lui, Shui Shan Lee, Hnin Yin Yin Nyein, I-Ming Hsing

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2024.116866 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Yumeng Cao und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong Special Administrat…. Hauptthemen laut MEDLINE: Biosensing Techniques, Nucleic Acid Amplification Techniques, SARS-CoV-2, Viral Load. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Innovation and Technology Commission - Hong Kong, University Grants Committee Research Grants Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

CoRPLA (CRISPR-regulated One-pot Recombinase Polymerase Loop-mediated Amplification) is an amplicon-depleted skin-temperature operated iNAAT designed for at-home testing. It uses specially designed loop primers to enhance isothermal amplification, triggering Cas12 for in-situ amplicon depletion and signal amplification. This method addresses issues like amplicon-derived aerosol contamination and complex assay formats, enabling quantitative detection with sub-attomolar sensitivity (0.5 cps/μL). CoRPLA employs a DNA hydrogel wearable tape for real-time, colorimetric readout, allowing visual differentiation of pathogen loads. It was validated with clinical samples for SARS-CoV-2, RSV, influenza A, and HPV, successfully identifying multi-level viral loads of the positive cases with results consistent with qPCR. Offering high sensitivity while eliminating false positives from aerosol contamination, CoRPLA bridges the molecular assay from benchtop to home for daily viral infections monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesNucleic Acid Amplification TechniquesSARS-CoV-2Viral LoadHumansCOVID-19Skin TemperatureInfluenza A virusRespiratory Syncytial VirusesCRISPR-Cas SystemsMolecular Diagnostic Techniques

Stichwörter der Autor:innen

CRISPR-Based reactionContamination-freeEquipment-freeLAMPRPASelf-testing

Autor:innen und Institutionen

  • Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong Special Administrative Region of China.
  • Department of Medicine & Therapeutics, The Chinese University of Hong Kong, Shatin, Hong Kong Special Administrative Region of China.
  • S.H. Ho Research Centre for Infectious Diseases, The Chinese University of Hong Kong, Shatin, Hong Kong Special Administrative Region of China.
  • Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong Special Administrative Region of China. Electronic address: hnyein@ust.hk.
  • Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong Special Administrative Region of China. Electronic address: kehsing@ust.hk.

Förderung

  • Innovation and Technology Commission - Hong Kong
  • University Grants Committee Research Grants Council

Zitieren

APA

Cao, Y., Lin, H., Lu, X., Wu, X., Zhu, Y., Zhao, Z., Li, Y., Borje, S., Lui, G. C. Y., Lee, S. S., Nyein, H. Y. Y., & Hsing, I. M. (2025). Benchtop to at-home test: Amplicon-depleted CRISPR-regulated loop mediated amplification at skin-temperature for viral load monitoring. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116866

Vancouver

Cao Y, Lin H, Lu X, Wu X, Zhu Y, Zhao Z, et al. Benchtop to at-home test: Amplicon-depleted CRISPR-regulated loop mediated amplification at skin-temperature for viral load monitoring. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2024.116866

BibTeX
@article{Cao2025,
  author = {Cao, Yumeng and Lin, Haosi and Lu, Xiao and Wu, Xiaolong and Zhu, Yuxuan and Zhao, Zibin and Li, Yanan and Borje, Samantha and Lui, Grace C Y and Lee, Shui Shan and Nyein, Hnin Yin Yin and Hsing, I-Ming},
  title = {Benchtop to at-home test: Amplicon-depleted CRISPR-regulated loop mediated amplification at skin-temperature for viral load monitoring},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2024.116866}
}
Kostenlos starten →