EUVIMEDEUVIMED entdecken
Crossref

Non-enzymatic g-C3N4 supported CuO derived-biochar based electrochemical sensors for trace level detection of malathion

Waribam Stella Devi, Ranjeet Kaur, Aashima Sharma, Sakshi Thakur, S K Mehta, Vaseem Raja, Farid S Ataya

Biosensors and Bioelectronics · 2025-01 · 267 · 116808

DOI: 10.1016/j.bios.2024.116808 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-01. Verfasst von Waribam Stella Devi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Chandigarh University, Mohali, Gharuan, Punjab, 140413, India. Hauptthemen laut MEDLINE: Copper, Biosensing Techniques, Electrochemical Techniques, Limit of Detection. Die Arbeit wurde bisher 44-mal zitiert (Crossref) und nennt 59 Literaturangaben. Gefördert von: Chandigarh University, King Saud University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Malathion (MALA), a widely used insecticide, even at trace levels exhibits deleterious effects towards respiratory tracts, and nervous system, necessitating its detection. Herein, we have offered non-enzymatic trace level monitoring of MALA using g-C3N4 supported CuO-derived biochar. The present B-CuO/g-C3N4 based electrochemical sensor is synthesized using hydrothermal approach followed by calcination at high temperature. The result unveiled the strong interactions, high charge separation efficiency, significant porosity leading to excellent electrochemically active surface area 9.88 × 10-5 cm2 with least charge transfer resistance (RCT) value of 35.2 K Ω. The B-CuO/g-C3N4 based nanocomposite offered excellent complex formation ability with MALA and square wave anodic stripping voltametric method (SWASV) generates an enhanced electrochemical signal due to oxidation of MALA. Following all necessary optimizations, the sensor was capable to exhibit limit of detection (LOD) value of 1.2 pg mL-1 with R2 = 0.968. The modified biosensor offered its potential towards detection of MALA in apple and tomato samples with a recovery ranging from 87.64 to 120.59%. This novel B-CuO/g-C3N4 ternary nanocomposite provides non-enzymatic detection of MALA having excellent electrochemical properties and hence opens new pathways for exploring the use of biochar in other electrochemical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CopperBiosensing TechniquesElectrochemical TechniquesLimit of DetectionMalathionInsecticidesMalusNitrogen CompoundsSolanum lycopersicumNitrilesGraphiteNanocompositesFood Contamination

Stichwörter der Autor:innen

BiocharElectrochemical sensorHydrothermalMalathion (MALA)Non-enzymaticSquare wave anodic stripping voltametric (SWASV)

Substanzen

Coppercupric oxideMalathionInsecticidesgraphitic carbon nitrideNitrogen CompoundsNitrilesGraphite

Autor:innen und Institutionen

  • Department of Chemistry, Chandigarh University, Mohali, Gharuan, Punjab, 140413, India.
  • University Centre for Research & Development (UCRD), Department of Chemistry, Chandigarh University, Mohali, Gharuan, Punjab, 140413, India. Electronic address: rkmatharu49@gmail.com.
  • Deparment of Chemistry, Panjab University, Sector-14, Chandigarh, India.
  • Deparment of Chemistry, Panjab University, Sector-14, Chandigarh, India. Electronic address: skmehta@pu.ac.in.
  • University Centre for Research and Development, Chandigarh University, Gharuan, Mohali, Punjab, 140413, India.
  • Department of Biochemistry, College of Science, King Saud University, P.O. Box 2455, Riyadh, 11451, Saudi Arabia.

Förderung

  • Chandigarh University
  • King Saud University

Zitieren

APA

Devi, W. S., Kaur, R., Sharma, A., Thakur, S., Mehta, S. K., Raja, V., & Ataya, F. S. (2025). Non-enzymatic g-C3N4 supported CuO derived-biochar based electrochemical sensors for trace level detection of malathion. Biosensors and Bioelectronics, 267, 116808. https://doi.org/10.1016/j.bios.2024.116808

Vancouver

Devi WS, Kaur R, Sharma A, Thakur S, Mehta SK, Raja V, et al. Non-enzymatic g-C3N4 supported CuO derived-biochar based electrochemical sensors for trace level detection of malathion. Biosensors and Bioelectronics. 2025;267:116808. doi:10.1016/j.bios.2024.116808

BibTeX
@article{Devi2025,
  author = {Devi, Waribam Stella and Kaur, Ranjeet and Sharma, Aashima and Thakur, Sakshi and Mehta, S K and Raja, Vaseem and Ataya, Farid S},
  title = {Non-enzymatic g-C3N4 supported CuO derived-biochar based electrochemical sensors for trace level detection of malathion},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  volume = {267},
  pages = {116808},
  doi = {10.1016/j.bios.2024.116808}
}
Kostenlos starten →