EUVIMEDEUVIMED entdecken
Open Access

Dual action electrochemical bandage operated by a programmable multimodal wearable potentiostat

Ibrahim Bozyel, Derek Fleming, Kim Won-Jun, Peter F Rosen, Suzanne Gelston, Dilara Ozdemir, Paige Kies, Christina Koscianski, Melissa Karau, Suat U Ay, Robin Patel, Haluk Beyenal

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2024.116791 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Ibrahim Bozyel und 11 weiteren Autor:innen. Beteiligte Einrichtung: The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA; Department of Electrical…. Hauptthemen laut MEDLINE: Biofilms, Hydrogen Peroxide, Bandages, Hypochlorous Acid. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAID NIH HHS, NIGMS NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We have developed electrochemical bandage (e-bandage) prototypes that generate the reactive oxygen species hypochlorous acid (HOCl) or hydrogen peroxide (H2O2) for potential use to treat biofilm-infected wounds in humans. We have shown that both e-bandage-generated HOCl and H2O2 kill biofilms in vitro and in infected wounds on mice, with the former being more active in vitro. The H2O2-generating e-bandage, more so than the HOCl-generating e-bandage, was associated with improved healing of infected wounds. Here, a strategy in which H2O2 and HOCl are alternately generated-for dual action-was explored. The goal was to develop a programmable multimodal wearable potentiostat [PMWP] that can generate HOCl or H2O2, as needed. An ultralow-power microcontroller unit was developed to manage operation of the PMWP. The system was operated with a 260-mAh capacity coin battery and weighed 4.6 g, making it suitable for future small animal experiments (and ultimately, potential evaluation in humans). As assessed using electrochemical parameters, the device functioned comparably to a commercial benchtop potentiostat. To confirm antimicrobial activity, PMWP-controlled e-bandages were tested in vitro against clinical isolates of methicillin-resistant Staphylococcus aureus, Pseudomonas aeruginosa, Acinetobacter baumannii, Enterococcus faecium, and Candida auris. When programmed to deliver HOCl followed by H2O2, PMWP-controlled e-bandages exhibited activity against biofilms of all study isolates tested. Finally, we demonstrated the PMWP's usability in a murine wound infection model.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BiofilmsHydrogen PeroxideBandagesHypochlorous AcidMethicillin-Resistant Staphylococcus aureusWearable Electronic DevicesPseudomonas aeruginosaHumansAnimalsMiceBiosensing TechniquesEquipment DesignWound InfectionStaphylococcal Infections

Stichwörter der Autor:innen

BiofilmElectrochemical bandageMurine wound infection modelWearable potentiostatWound healing

Substanzen

Hydrogen PeroxideHypochlorous Acid

Autor:innen und Institutionen

  • The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA; Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester,…
  • Division of Clinical Microbiology, Mayo Clinic, Rochester, MN, USA. Electronic address: fleming.derek@mayo.edu.
  • The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA. Electronic address: won-jun.kim@wsu.edu.
  • Mayo Clinic Alix School of Medicine, USA. Electronic address: rosen.peter@mayo.edu.
  • The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA. Electronic address: suzanne.gelston@wsu.edu.
  • The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA. Electronic address: dilara.ozdemir@wsu.edu.

Förderung

  • NIAID NIH HHS
  • NIGMS NIH HHS
  • National Institutes of Health
  • National Institute of Allergy and Infectious Diseases

Zitieren

APA

Bozyel, I., Fleming, D., Won-Jun, K., Rosen, P. F., Gelston, S., Ozdemir, D., Kies, P., Koscianski, C., Karau, M., Ay, S. U., Patel, R., & Beyenal, H. (2025). Dual action electrochemical bandage operated by a programmable multimodal wearable potentiostat. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116791

Vancouver

Bozyel I, Fleming D, Won-Jun K, Rosen PF, Gelston S, Ozdemir D, et al. Dual action electrochemical bandage operated by a programmable multimodal wearable potentiostat. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2024.116791

BibTeX
@article{Bozyel2025,
  author = {Bozyel, Ibrahim and Fleming, Derek and Won-Jun, Kim and Rosen, Peter F and Gelston, Suzanne and Ozdemir, Dilara and Kies, Paige and Koscianski, Christina and Karau, Melissa and Ay, Suat U and Patel, Robin and Beyenal, Haluk},
  title = {Dual action electrochemical bandage operated by a programmable multimodal wearable potentiostat},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2024.116791}
}
Kostenlos starten →