Enhancing cardiovascular health monitoring: Simultaneous multi-artery cardiac markers recording with flexible and bio-compatible AlN piezoelectric sensors
Biosensors and Bioelectronics · 2025
DOI: 10.1016/j.bios.2024.116790 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Marco Cinquino und 9 weiteren Autor:innen. Beteiligte Einrichtung: Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy. Electronic address: marco.cinquino@iit.it. Hauptthemen laut MEDLINE: Pulse Wave Analysis, Biosensing Techniques, Cardiovascular Diseases. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Italian Space Agency, European Commission.
Abstract (Originalsprache)
Continuous monitoring of cardiovascular parameters like pulse wave velocity (PWV), blood pressure wave (BPW), stiffness index (SI), reflection index (RI), mean arterial pressure (MAP), and cardio-ankle vascular index (CAVI) has significant clinical importance for the early diagnosis of cardiovascular diseases (CVDs). Standard approaches, including echocardiography, impedance cardiography, or hemodynamic monitoring, are hindered by expensive and bulky apparatus and accessibility only in specialized facilities. Moreover, noninvasive techniques like sphygmomanometry, electrocardiography, and arterial tonometry often lack accuracy due to external electrical interferences, artifacts produced by unreliable electrode contacts, misreading from placement errors, or failure in detecting transient issues and trends. Here, we report a bio-compatible, flexible, noninvasive, low-cost piezoelectric sensor for continuous and real-time cardiovascular monitoring. The sensor, utilizing a thin aluminum nitride film on a flexible Kapton substrate, is used to extract heart rate, blood pressure waves, pulse wave velocities, and cardio-ankle vascular index from four arterial pulse sites: carotid, brachial, radial, and posterior tibial arteries. This simultaneous recording, for the first time in the same experiment, allows to provide a comprehensive cardiovascular patient's health profile. In a test with a 28-year-old male subject, the sensor yielded the SI = 7.1 ± 0.2 m/s, RI = 54.4 ± 0.5 %, MAP = 86.2 ± 1.5 mmHg, CAVI = 7.8 ± 0.2, and seven PWVs from the combination of the four different arterial positions, in good agreement with the typical values reported in the literature. These findings make the proposed technology a powerful tool to facilitate personalized medical diagnosis in preventing CVDs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy. Electronic address: marco.cinquino@iit.it.
- Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy; Department of Electronics and Telecommunications, Politecnico di Torino, Corso Duca degli Abruzzi, Torino, TO, 10129…
- Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy; Department of Innovation Engineering, University of Salento, Lecce, LE, 73100, Italy.
- Inmatica S.p.A., BE-Pilot Palace, Strada Comunale Tufi, Monteroni di Lecce, LE, 73047, Italy.
- Center for Biomolecular Nanotechnologies, Istituto Italiano di Tecnologia, Arnesano, LE, 73010, Italy.
- Department of Innovation Engineering, University of Salento, Lecce, LE, 73100, Italy.
Förderung
- Italian Space Agency
- European Commission
Zitieren
APA
Cinquino, M., Demir, S. M., Shumba, A. T., Schioppa, E. J., Fachechi, L., Rizzi, F., Qualtieri, A., Patrono, L., Mastronardi, V. M., & De Vittorio, M. (2025). Enhancing cardiovascular health monitoring: Simultaneous multi-artery cardiac markers recording with flexible and bio-compatible AlN piezoelectric sensors. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116790
Vancouver
Cinquino M, Demir SM, Shumba AT, Schioppa EJ, Fachechi L, Rizzi F, et al. Enhancing cardiovascular health monitoring: Simultaneous multi-artery cardiac markers recording with flexible and bio-compatible AlN piezoelectric sensors. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2024.116790
BibTeX
@article{Cinquino2025,
author = {Cinquino, Marco and Demir, Suleyman Mahircan and Shumba, Angela Tafadzwa and Schioppa, Enrico Junior and Fachechi, Luca and Rizzi, Francesco and Qualtieri, Antonio and Patrono, Luigi and Mastronardi, Vincenzo Mariano and De Vittorio, Massimo},
title = {Enhancing cardiovascular health monitoring: Simultaneous multi-artery cardiac markers recording with flexible and bio-compatible AlN piezoelectric sensors},
journal = {Biosensors and Bioelectronics},
year = {2025},
doi = {10.1016/j.bios.2024.116790}
}
EUVIMED