Ultrasensitive detection of SCCA employing a graphene oxide integrated microfiber ring laser biosensor
Biosensors and Bioelectronics · 2025-01 · 267 · 116772
DOI: 10.1016/j.bios.2024.116772 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-01. Verfasst von Zefeng Li und 13 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing, 100876, China. Hauptthemen laut MEDLINE: Graphite, Biosensing Techniques, Serpins, Antigens, Neoplasm. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Beijing University of Posts and Telecommunications, Royal Society, National Natural Science Foundation of China.
Abstract (Originalsprache)
Squamous cell carcinoma antigen (SCCA) is one of the most commonly detected cancer biomarkers for a variety of cancers. In this paper, a microfiber ring laser biosensor with a graphene oxide linking layer for SCCA detection was proposed and experimentally demonstrated. SCCA antibody immobilized on graphene oxide surface binds specifically to SCCA, and induces refractive index variation over the surface of the microfiber biosensor, which leads to a wavelength shift of the microfiber ring laser biosensor. The experimental results show that the proposed laser biosensor can detect SCCA with concentrations from 0.01 to 50 ng/mL, and the calculated detection limit can be as low as 1.3 pg/mL. Additionally, the label-free quantitative detection of SCCA using the proposed microfiber biosensor was verified experimentally according to the corresponding regression equation, and the results agree well with clinical examination detection. This constructed microfiber biosensor may have promising practical applications in analytical detection, medical diagnostics, etc.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing, 100876, China.
- Cancer Hospital of Shantou University Medical College, Shantou, 515000, China.
- Depatment of Applied Physics, Science College, Shantou University, Shantou, 515000, China.
- State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing, 100876, China. Electronic address: yuanjinhui81@bupt.edu.cn.
- Department of Physics and Electrical Engineering, Northumbria University, Newcastle upon Tyne, NE1 8ST, United Kingdom; Key Laboratory for Optoelectronic Information Perception and Instrumentation of Jiangxi Province, N…
Förderung
- Beijing University of Posts and Telecommunications
- Royal Society
- National Natural Science Foundation of China
Zitieren
APA
Li, Z., Xie, R., Sun, G., Liu, X., Xin, H., Chen, Y., Chen, S., Rao, L., Yan, B., Wang, K., Sang, X., Yu, C., Yuan, J., & Wu, Q. (2025). Ultrasensitive detection of SCCA employing a graphene oxide integrated microfiber ring laser biosensor. Biosensors and Bioelectronics, 267, 116772. https://doi.org/10.1016/j.bios.2024.116772
Vancouver
Li Z, Xie R, Sun G, Liu X, Xin H, Chen Y, et al. Ultrasensitive detection of SCCA employing a graphene oxide integrated microfiber ring laser biosensor. Biosensors and Bioelectronics. 2025;267:116772. doi:10.1016/j.bios.2024.116772
BibTeX
@article{Li2025,
author = {Li, Zefeng and Xie, Ruen and Sun, Guoyong and Liu, Xiaokai and Xin, Hu and Chen, Yuping and Chen, Shaobin and Rao, Lan and Yan, Binbin and Wang, Kuiru and Sang, Xinzhu and Yu, Chongxiu and Yuan, Jinhui and Wu, Qiang},
title = {Ultrasensitive detection of SCCA employing a graphene oxide integrated microfiber ring laser biosensor},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {267},
pages = {116772},
doi = {10.1016/j.bios.2024.116772}
}
EUVIMED