Real-time electro-mechanical profiling of dynamically beating human cardiac organoids by coupling resistive skins with microelectrode arrays
Biosensors and Bioelectronics · 2025-01 · 267 · 116752
DOI: 10.1016/j.bios.2024.116752 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-01. Verfasst von Jialiang Yin und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical & Biological Engineering, Monash University, Clayton, Victoria, 3800, Australia. Hauptthemen laut MEDLINE: Microelectrodes, Organoids, Doxorubicin, Biosensing Techniques. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Health and Medical Research Council, Australian Research Council.
Abstract (Originalsprache)
Cardiac organoids differentiated from induced pluripotent stem cells are emerging as a promising platform for pre-clinical drug screening, assessing cardiotoxicity, and disease modelling. However, it is challenging to simultaneously measure mechanical contractile forces and electrophysiological signals of cardiac organoids in real-time and in-situ with the existing methods. Here, we present a biting-inspired sensory system based on a resistive skin sensor and a microelectrode array. The bite-like contact can be established with a micromanipulator to precisely position the resistive skin sensor on the top of the cardiac organoid while the 3D microneedle electrode array probes from underneath. Such reliable contact is key to achieving simultaneous electro-mechanical measurements. We demonstrate the use of our system for modelling cardiotoxicity with the anti-cancer drug doxorubicin. The electro-mechanical parameters described here elucidate the acute cardiotoxic effects induced by doxorubicin. This integrated electro-mechanical system enables a suite of new diagnostic options for assessing cardiac organoids and tissues.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemical & Biological Engineering, Monash University, Clayton, Victoria, 3800, Australia.
- Department of Medicine and Surgery, University of Melbourne, VIC, Australia; O'Brien Institute Department, St. Vincent's Institute of Medical Research, VIC, Australia.
- O'Brien Institute Department, St. Vincent's Institute of Medical Research, VIC, Australia.
- Department of Biochemistry & Molecular Biology, Biomedicine Discovery Institute, Clayton, Victoria, 3800, Australia; Faculty of Engineering, Monash Institute of Medical Engineering (MIME), Monash University, Clayton, Vi…
- Department of Medicine and Surgery, University of Melbourne, VIC, Australia; O'Brien Institute Department, St. Vincent's Institute of Medical Research, VIC, Australia; Drug Discovery Biology, Faculty of Pharmacy and Pha…
- Department of Chemical & Biological Engineering, Monash University, Clayton, Victoria, 3800, Australia; The Melbourne Centre for Nanofabrication, Clayton, Victoria, 3800, Australia. Electronic address: wenlong.cheng@syd…
Förderung
- National Health and Medical Research Council
- Australian Research Council
Zitieren
APA
Yin, J., Lees, J. G., Gong, S., Nguyen, J. T., Phang, R. J., Shi, Q., Huang, Y., Kong, A. M., Dyson, J. M., Lim, S. Y., & Cheng, W. (2025). Real-time electro-mechanical profiling of dynamically beating human cardiac organoids by coupling resistive skins with microelectrode arrays. Biosensors and Bioelectronics, 267, 116752. https://doi.org/10.1016/j.bios.2024.116752
Vancouver
Yin J, Lees JG, Gong S, Nguyen JT, Phang RJ, Shi Q, et al. Real-time electro-mechanical profiling of dynamically beating human cardiac organoids by coupling resistive skins with microelectrode arrays. Biosensors and Bioelectronics. 2025;267:116752. doi:10.1016/j.bios.2024.116752
BibTeX
@article{Yin2025,
author = {Yin, Jialiang and Lees, Jarmon G and Gong, Shu and Nguyen, John Tan and Phang, Ren Jie and Shi, Qianqian and Huang, Yifeng and Kong, Anne M and Dyson, Jennifer M and Lim, Shiang Y and Cheng, Wenlong},
title = {Real-time electro-mechanical profiling of dynamically beating human cardiac organoids by coupling resistive skins with microelectrode arrays},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {267},
pages = {116752},
doi = {10.1016/j.bios.2024.116752}
}
EUVIMED