EUVIMEDEUVIMED entdecken
Crossref

Solid-phase extraction coupled to automated centrifugal microfluidics SERS: Improving quantification of therapeutic drugs in human serum

Gohar Soufi, Isidro Badillo-Ramírez, Laura Serioli, Raheel Altaf Raja, Kjeld Schmiegelow, Kinga Zor, Anja Boisen

Biosensors and Bioelectronics · 2024-12 · 266 · 116725

DOI: 10.1016/j.bios.2024.116725 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-12. Verfasst von Gohar Soufi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical Universit…. Hauptthemen laut MEDLINE: Solid Phase Extraction, Lamotrigine, Spectrum Analysis, Raman, Methotrexate. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Surface-enhanced Raman spectroscopy (SERS) is a powerful method in analytical chemistry, but its application in real-life medical settings has been limited due to technical challenges. In this work, we introduce an innovative approach that is meant to advance the automation of microfluidics SERS to improve reproducibility and label-free quantification of two widely used therapeutic drugs, methotrexate (MTX) and lamotrigine (LTG), in human serum. Our methodology involves a miniaturized solid-phase extraction (μ-SPE) method coupled to a centrifugal microfluidics disc with incorporated SERS substrates (CD-SERS). The CD-SERS platform enables simultaneous controlled sample wetting and accurate SERS mapping. Together with the assay we implemented a machine learning method based on Partial Least Squares Regression (PLSR) for robust data analysis and drug quantification. The results indicate that combining μ-SPE with CD-SERS (μ-SPE to CD-SERS) led to a substantial improvement in the signal-to-noise ratio compared to combining CD-SERS with ultrafiltration or protein precipitation. The PLSR model enabled us to obtain the limit of detection and quantification for MTX as 2.90 and 8.92 μM, respectively, and for LTG as 10.76 and 32.29 μM. We also validated our μ-SPE to CD-SERS method for MTX against HPLC and immunoassay (p-value

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Solid Phase ExtractionLamotrigineSpectrum Analysis, RamanMethotrexateHumansBiosensing TechniquesLimit of DetectionMicrofluidicsEquipment DesignCentrifugation

Stichwörter der Autor:innen

Centrifugal microfluidicsMachine learningSERSSolid-phase extraction

Substanzen

LamotrigineMethotrexate

Autor:innen und Institutionen

  • Center for Intelligent Drug Delivery and Sensing Using Microcontainers and Nanomechanics (IDUN), Department of Health Technology, Technical University of Denmark, Kongens Lyngby, 2800, Denmark; BioInnovation Institute F…
  • Department of Paediatrics and Adolescent Medicine, Rigshospitalet University Hospital, Copenhagen, 2100, Denmark.

Zitieren

APA

Soufi, G., Badillo-Ramírez, I., Serioli, L., Altaf Raja, R., Schmiegelow, K., Zor, K., & Boisen, A. (2024). Solid-phase extraction coupled to automated centrifugal microfluidics SERS: Improving quantification of therapeutic drugs in human serum. Biosensors and Bioelectronics, 266, 116725. https://doi.org/10.1016/j.bios.2024.116725

Vancouver

Soufi G, Badillo-Ramírez I, Serioli L, Altaf Raja R, Schmiegelow K, Zor K, et al. Solid-phase extraction coupled to automated centrifugal microfluidics SERS: Improving quantification of therapeutic drugs in human serum. Biosensors and Bioelectronics. 2024;266:116725. doi:10.1016/j.bios.2024.116725

BibTeX
@article{Soufi2024,
  author = {Soufi, Gohar and Badillo-Ramírez, Isidro and Serioli, Laura and Altaf Raja, Raheel and Schmiegelow, Kjeld and Zor, Kinga and Boisen, Anja},
  title = {Solid-phase extraction coupled to automated centrifugal microfluidics SERS: Improving quantification of therapeutic drugs in human serum},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {266},
  pages = {116725},
  doi = {10.1016/j.bios.2024.116725}
}
Kostenlos starten →