Fabrication of high-resolution, flexible, laser-induced graphene sensors via stencil masking
Biosensors and Bioelectronics · 2024-11 · 264 · 116649
DOI: 10.1016/j.bios.2024.116649 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-11. Verfasst von Kaylee M Clark und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Hawai'i at Mānoa, Honolulu, HI, 96822, USA. Hauptthemen laut MEDLINE: Graphite, Biosensing Techniques, Wearable Electronic Devices, Equipment Design. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 80 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, National Science Foundation, Office of Naval Research.
Abstract (Originalsprache)
The advent of wearable sensing platforms capable of continuously monitoring physiological parameters indicative of health status have resulted in a paradigm shift for clinical medicine. The accessibility and adaptability of such portable, unobtrusive devices enables proactive, personalized care based on real-time physiological insights. While wearable sensing platforms exhibit powerful capabilities for continuously monitoring physiological parameters, device fabrication often requires specialized facilities and technical expertise, restricting deployment opportunities and innovation potential. The recent emergence of rapid prototyping approaches to sensor fabrication, such as laser-induced graphene (LIG), provides a pathway for circumventing these barriers through low-cost, scalable fabrication. However, inherent limitations in laser processing restrict the spatial resolution of LIG-based flexible electronic devices to the minimum laser spot size. For a CO2 laser-a commonly reported laser for device production-this corresponds to a feature size of ∼120 μm. Here, we demonstrate a facile, low-cost stencil-masking technique to reduce the minimum resolvable feature size of a LIG-based device from 120 ± 20 μm to 45 ± 3 μm when fabricated by CO2 laser. Characterization of device performance reveals this stencil-masked LIG (s-LIG) method yields a concomitant improvement in electrical properties, which we hypothesize is the result of changes in macrostructure of the patterned LIG. We showcase the performance of this fabrication method via production of common sensors including temperature and multi-electrode electrochemical sensors. We fabricate fine-line microarray electrodes not typically achievable via native CO2 laser processing, demonstrating the potential of the expanded design capabilities. Comparing microarray sensors made with and without the stencil to traditional macro LIG electrodes reveals the s-LIG sensors have significantly reduced capacitance for similar electroactive surface areas. Beyond improving sensor performance, the increased resolution enabled by this metal stencil technique expands capabilities for scalable fabrication of high-performance wearable sensors in low-resource settings without reliance on traditional fabrication pathways.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Mechanical Engineering, University of Hawai'i at Mānoa, Honolulu, HI, 96822, USA.
- Department of Electrical Engineering, University of Hawai'i at Mānoa, Honolulu, HI, 96822, USA.
- Department of Mechanical Engineering, University of Hawai'i at Mānoa, Honolulu, HI, 96822, USA; Department of Cell and Molecular Biology, John. A. Burns School of Medicine, University of Hawai'i at Mānoa, Honolulu, HI,…
Förderung
- NIGMS NIH HHS
- National Science Foundation
- Office of Naval Research
- University of Hawai'i
- National Institutes of Health
- National Institute of General Medical Sciences
- Air Force Office of Scientific Research
Zitieren
APA
Clark, K. M., Nekoba, D. T., Viernes, K. L., Zhou, J., & Ray, T. R. (2024). Fabrication of high-resolution, flexible, laser-induced graphene sensors via stencil masking. Biosensors and Bioelectronics, 264, 116649. https://doi.org/10.1016/j.bios.2024.116649
Vancouver
Clark KM, Nekoba DT, Viernes KL, Zhou J, Ray TR. Fabrication of high-resolution, flexible, laser-induced graphene sensors via stencil masking. Biosensors and Bioelectronics. 2024;264:116649. doi:10.1016/j.bios.2024.116649
BibTeX
@article{Clark2024,
author = {Clark, Kaylee M and Nekoba, Deylen T and Viernes, Kian Laʻi and Zhou, Jie and Ray, Tyler R},
title = {Fabrication of high-resolution, flexible, laser-induced graphene sensors via stencil masking},
journal = {Biosensors and Bioelectronics},
year = {2024},
volume = {264},
pages = {116649},
doi = {10.1016/j.bios.2024.116649}
}
EUVIMED