Dual-mode photothermal/chemiluminescence vertical flow assay for sensitive point-of-care detection of carcinoembryonic antigen using Cu2-xAgxS@liposome on a filter membrane
Biosensors and Bioelectronics · 2024
DOI: 10.1016/j.bios.2024.116602 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Yunping Lai und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Pharmaceutical Sciences, State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Guangxi Key Lab…. Hauptthemen laut MEDLINE: Carcinoembryonic Antigen, Biosensing Techniques, Liposomes, Copper. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Guangxi Natural Science Foundation.
Abstract (Originalsprache)
Conventional lateral flow assays based on colorimetry and fluorescence still have shortages in sensitivity and selectivity due to the severe background interference from complex human fluid sample matrices. In this work, Cu2-xAgxS nanocrystals with high photothermal conversion efficiency and good peroxidase-like activity were synthesized and applied in the construction of a dual-mode near-infrared-photothermal/chemiluminescence (CL) vertical flow assay of carcinoembryonic antigen (CEA). These two-mode principles showed nearly zero background and the synthesized Cu2-xAgxS exhibited a high photothermal conversion efficiency of 75.23%, enabling the luminol-H2O2 CL system to have over 4 min of chemiluminescence. By combining filter membrane enrichment, Cu2-xAgxS@liposome encapsulation amplification, and nanozyme catalysis, a dual-mode photothermal/CL portable assay was constructed for sensitive and accurate detection of CEA in serum, with linear ranges of 0.02-40 and 0.001-30 ng mL-1, and detection limits of 0.0023 and 0.00029 ng mL-1, respectively. Furthermore, a smartphone application and a 3D printing device were combined for point-of-care testing. This assay can be completed within 20 min, with simple operation and no need for large instruments. It exhibited good sensitivity, selectivity, and stability, and is expected to be used in early diagnosis and prevention of relevant diseases in resource-limited areas.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chemistry and Pharmaceutical Sciences, State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Guangxi Key Laboratory of Environmental Processes and Remediation in Ecologically Fra…
- Chongqing Key Laboratory of Kinase Modulators as Innovative Medicine, College of Pharmacy (International Academy of Targeted Therapeutics and Innovation), Chongqing University of Arts and Sciences, Chongqing, 402160, PR…
Förderung
- National Natural Science Foundation of China
- Guangxi Natural Science Foundation
Zitieren
APA
Lai, Y., Huang, J., Tang, D., Chen, X., Hou, L., Zhao, S., & Lin, T. (2024). Dual-mode photothermal/chemiluminescence vertical flow assay for sensitive point-of-care detection of carcinoembryonic antigen using Cu2-xAgxS@liposome on a filter membrane. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116602
Vancouver
Lai Y, Huang J, Tang D, Chen X, Hou L, Zhao S, et al. Dual-mode photothermal/chemiluminescence vertical flow assay for sensitive point-of-care detection of carcinoembryonic antigen using Cu2-xAgxS@liposome on a filter membrane. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116602
BibTeX
@article{Lai2024,
author = {Lai, Yunping and Huang, Jiamin and Tang, Dianyong and Chen, Xinlian and Hou, Li and Zhao, Shulin and Lin, Tianran},
title = {Dual-mode photothermal/chemiluminescence vertical flow assay for sensitive point-of-care detection of carcinoembryonic antigen using Cu2-xAgxS@liposome on a filter membrane},
journal = {Biosensors and Bioelectronics},
year = {2024},
doi = {10.1016/j.bios.2024.116602}
}
EUVIMED