EUVIMEDEUVIMED entdecken
Crossref

Dual-mode photothermal/chemiluminescence vertical flow assay for sensitive point-of-care detection of carcinoembryonic antigen using Cu2-xAgxS@liposome on a filter membrane

Yunping Lai, Jiamin Huang, Dianyong Tang, Xinlian Chen, Li Hou, Shulin Zhao, Tianran Lin

Biosensors and Bioelectronics · 2024

DOI: 10.1016/j.bios.2024.116602 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Yunping Lai und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Pharmaceutical Sciences, State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Guangxi Key Lab…. Hauptthemen laut MEDLINE: Carcinoembryonic Antigen, Biosensing Techniques, Liposomes, Copper. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Guangxi Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional lateral flow assays based on colorimetry and fluorescence still have shortages in sensitivity and selectivity due to the severe background interference from complex human fluid sample matrices. In this work, Cu2-xAgxS nanocrystals with high photothermal conversion efficiency and good peroxidase-like activity were synthesized and applied in the construction of a dual-mode near-infrared-photothermal/chemiluminescence (CL) vertical flow assay of carcinoembryonic antigen (CEA). These two-mode principles showed nearly zero background and the synthesized Cu2-xAgxS exhibited a high photothermal conversion efficiency of 75.23%, enabling the luminol-H2O2 CL system to have over 4 min of chemiluminescence. By combining filter membrane enrichment, Cu2-xAgxS@liposome encapsulation amplification, and nanozyme catalysis, a dual-mode photothermal/CL portable assay was constructed for sensitive and accurate detection of CEA in serum, with linear ranges of 0.02-40 and 0.001-30 ng mL-1, and detection limits of 0.0023 and 0.00029 ng mL-1, respectively. Furthermore, a smartphone application and a 3D printing device were combined for point-of-care testing. This assay can be completed within 20 min, with simple operation and no need for large instruments. It exhibited good sensitivity, selectivity, and stability, and is expected to be used in early diagnosis and prevention of relevant diseases in resource-limited areas.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carcinoembryonic AntigenBiosensing TechniquesLiposomesCopperLimit of DetectionLuminescent MeasurementsHumansLuminolHydrogen PeroxideNanoparticles

Stichwörter der Autor:innen

ChemiluminescenceMembranePhotothermalPoint-of-care testingSmartphone

Substanzen

Carcinoembryonic AntigenLiposomesCopperLuminolHydrogen Peroxide

Autor:innen und Institutionen

  • School of Chemistry and Pharmaceutical Sciences, State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Guangxi Key Laboratory of Environmental Processes and Remediation in Ecologically Fra…
  • Chongqing Key Laboratory of Kinase Modulators as Innovative Medicine, College of Pharmacy (International Academy of Targeted Therapeutics and Innovation), Chongqing University of Arts and Sciences, Chongqing, 402160, PR…

Förderung

  • National Natural Science Foundation of China
  • Guangxi Natural Science Foundation

Zitieren

APA

Lai, Y., Huang, J., Tang, D., Chen, X., Hou, L., Zhao, S., & Lin, T. (2024). Dual-mode photothermal/chemiluminescence vertical flow assay for sensitive point-of-care detection of carcinoembryonic antigen using Cu2-xAgxS@liposome on a filter membrane. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116602

Vancouver

Lai Y, Huang J, Tang D, Chen X, Hou L, Zhao S, et al. Dual-mode photothermal/chemiluminescence vertical flow assay for sensitive point-of-care detection of carcinoembryonic antigen using Cu2-xAgxS@liposome on a filter membrane. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116602

BibTeX
@article{Lai2024,
  author = {Lai, Yunping and Huang, Jiamin and Tang, Dianyong and Chen, Xinlian and Hou, Li and Zhao, Shulin and Lin, Tianran},
  title = {Dual-mode photothermal/chemiluminescence vertical flow assay for sensitive point-of-care detection of carcinoembryonic antigen using Cu2-xAgxS@liposome on a filter membrane},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  doi = {10.1016/j.bios.2024.116602}
}
Kostenlos starten →