Dual-modal biosensor for mercuric ion detection based on Cu2O@Cu2S/D-TA COF heterojunction with excellent catalase-like, electrochemical and photoelectrochemical properties
Biosensors and Bioelectronics · 2024-10 · 262 · 116568
DOI: 10.1016/j.bios.2024.116568 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-10. Verfasst von Yudie Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Shandong University, Jinan, Shandong, 250100, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Copper, Mercury, Electrochemical Techniques. Die Arbeit wurde bisher 96-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
In this study, a dual-mode biosensor based on the heterojunction of Cu2O@Cu2S/D-TA COF was constructed for ultra-sensitive detection of Hg2+ using both photoelectrochemical and electrochemical approaches. Briefly, a 2D ultra-thin covalent organic framework film (D-TA COF film) with excellent photoelectrochemical signals was prepared on ITO surfaces through an in situ growth method. Subsequently, the probe H1 was immobilized onto the biosensor via Au-S bonds. In the presence of Hg2+, the formation of T-Hg2+-T complexes triggered hybridization chain reactions (HCR), leading to the attachment of abundant Cu2O@Cu2S probes onto the biosensor. As a p-type semiconductor, Cu2O@Cu2S could form a heterojunction with the underlying D-TA COF films. Meanwhile, it exhibited catalase-like activity, and the O2 produced by its catalytic decomposition of H2O2 can interact with the D-TA COF films, thus achieving double amplification of the photocurrent signal. Benefiting from the excellent and inherent Cu2+/Cu+ redox pairs of Cu2O@Cu2S, satisfactory differential pulse voltammetry (DPV) signals were obtained. As expected, the dual-mode biosensor was realized with wider linear ranges and low detection limits. Additionally, the analytical performance for Hg2+ in real water samples was excellent. Briefly, this suggested approach offers a facile and highly efficient modality for monitoring heavy metal ions in aquatic environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chemistry and Chemical Engineering, Shandong University, Jinan, Shandong, 250100, China.
- College of Chemical Engineering and Environmental Chemistry, Weifang University, Weifang, 261061, China. Electronic address: lujitao@foxmail.com.
- School of Chemistry and Chemical Engineering, Shandong University, Jinan, Shandong, 250100, China. Electronic address: zhangxiaomei@sdu.edu.cn.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Yang, Y., Niu, X., Duan, B., Lu, J., & Zhang, X. (2024). Dual-modal biosensor for mercuric ion detection based on Cu2O@Cu2S/D-TA COF heterojunction with excellent catalase-like, electrochemical and photoelectrochemical properties. Biosensors and Bioelectronics, 262, 116568. https://doi.org/10.1016/j.bios.2024.116568
Vancouver
Yang Y, Niu X, Duan B, Lu J, Zhang X. Dual-modal biosensor for mercuric ion detection based on Cu2O@Cu2S/D-TA COF heterojunction with excellent catalase-like, electrochemical and photoelectrochemical properties. Biosensors and Bioelectronics. 2024;262:116568. doi:10.1016/j.bios.2024.116568
BibTeX
@article{Yang2024,
author = {Yang, Yudie and Niu, Xiankang and Duan, Binqiu and Lu, Jitao and Zhang, Xiaomei},
title = {Dual-modal biosensor for mercuric ion detection based on Cu2O@Cu2S/D-TA COF heterojunction with excellent catalase-like, electrochemical and photoelectrochemical properties},
journal = {Biosensors and Bioelectronics},
year = {2024},
volume = {262},
pages = {116568},
doi = {10.1016/j.bios.2024.116568}
}
EUVIMED