EUVIMEDEUVIMED entdecken
Crossref

Synergistic powering of DNA walker movement by endogenous dual enzymes for constructing dual-mode biosensors

Jinting Meng, Zihao Xu, Xinhao Li, Baozheng Wang, Xiaowei Zhang, Zikang Xie, Chen Zhang, Hong Wang, Yingwei Zhang

Biosensors and Bioelectronics · 2024-10 · 262 · 116566

DOI: 10.1016/j.bios.2024.116566 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-10. Verfasst von Jinting Meng und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Chemical Resource Engineering, College of Materials Science and Engineering, Beijing University of Chemical Technology, Beiji…. Hauptthemen laut MEDLINE: Biosensing Techniques, DNA-(Apurinic or Apyrimidinic Site) Lyase, DNA, Flap Endonucleases. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To achieve highly sensitive and reliable detection of apurinic/apyrimidinic endonuclease 1 (APE1), a critical cancer diagnostic biomarker, we designed a DNA walker-based dual-mode biosensor, utilizing cellular endogenous dual enzymes (APE 1 and Flap endonuclease 1 (FEN 1)) to collaborate in activating and propelling DNA walker motion on DNA-functionalized Au nanoparticles. Incorporating both fluorescence and electrochemical detection modes, this system leverages signal amplification from DNA walker movement and cascade amplification through tandem hybridization chain reactions (HCR), achieving highly sensitive detection of APE 1. In the fluorescence mode, continuous DNA walker movement, initiated by APE1 and driven by FEN1, generates a robust signal response within a concentration range of 0.01-500 U mL-1, presenting a good linearity in the concentration range of 0.01-10 U mL-1, with a detection limit of 0.01 U mL-1. In the electrochemical detection module, the cascade upstream DNA walker and downstream HCR dual signal amplification strategy further enhances the sensitivity of APE1 detection, extending the linear range to 0.01-50 U mL-1 and reducing the detection limit to 0.002 U mL-1. Rigorous validation demonstrates the biosensor's specificity and anti-interference capability against multiple enzymes. Moreover, it effectively distinguishes cancer cells from normal cell lysates, exhibiting excellent stability and consistency in the dual-modes. Overall, our findings underscore the efficacy of the developed dual-mode biosensor for detecting APE1 in serum and cell lysates samples, indicating its potential for clinical applications in disease diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesDNA-(Apurinic or Apyrimidinic Site) LyaseDNAFlap EndonucleasesMetal NanoparticlesLimit of DetectionGoldHumansElectrochemical Techniques

Stichwörter der Autor:innen

Apurinic/apyrimidinic endonuclease 1DNA walkerEndogenous dual enzymesFlap endonuclease 1Fluorescent/electrochemical dual-mode biosensor

Substanzen

DNA-(Apurinic or Apyrimidinic Site) LyaseAPEX1 protein, humanDNAFlap EndonucleasesGoldFEN1 protein, human

Autor:innen und Institutionen

  • State Key Laboratory of Chemical Resource Engineering, College of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing, 100029, China.
  • State Key Laboratory of Chemical Resource Engineering, College of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing, 100029, China. Electronic address: wanghong@mail.buct.edu.cn.
  • State Key Laboratory of Chemical Resource Engineering, College of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing, 100029, China. Electronic address: zhangyw@mail.buct.edu.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Meng, J., Xu, Z., Li, X., Wang, B., Zhang, X., Xie, Z., Zhang, C., Wang, H., & Zhang, Y. (2024). Synergistic powering of DNA walker movement by endogenous dual enzymes for constructing dual-mode biosensors. Biosensors and Bioelectronics, 262, 116566. https://doi.org/10.1016/j.bios.2024.116566

Vancouver

Meng J, Xu Z, Li X, Wang B, Zhang X, Xie Z, et al. Synergistic powering of DNA walker movement by endogenous dual enzymes for constructing dual-mode biosensors. Biosensors and Bioelectronics. 2024;262:116566. doi:10.1016/j.bios.2024.116566

BibTeX
@article{Meng2024,
  author = {Meng, Jinting and Xu, Zihao and Li, Xinhao and Wang, Baozheng and Zhang, Xiaowei and Xie, Zikang and Zhang, Chen and Wang, Hong and Zhang, Yingwei},
  title = {Synergistic powering of DNA walker movement by endogenous dual enzymes for constructing dual-mode biosensors},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {262},
  pages = {116566},
  doi = {10.1016/j.bios.2024.116566}
}
Kostenlos starten →