Spatial-resolved and self-calibrated 3D-printed photoelectrochemical biosensor engineered by multifunctional CeO2/CdS heterostructure for immunoassay
Biosensors and Bioelectronics · 2024-10 · 262 · 116553
DOI: 10.1016/j.bios.2024.116553 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-10. Verfasst von Shuzhen Lv und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Chemical Engineering, Key Laboratory of Shandong Provincial Universities for Functional Molecules and Materials, Qingdao Uni…. Hauptthemen laut MEDLINE: Biosensing Techniques, Cerium, Carcinoembryonic Antigen, Cadmium Compounds. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Qingdao Postdoctoral Science Foundation, Taishan Scholar Foundation of Shandong Province, Qingdao University of Science and Technology.
Abstract (Originalsprache)
A spatial-resolved and self-calibrated photoelectrochemical (PEC) biosensor has been fabricated by a multifunctional CeO2/CdS heterostructure, achieving portable and sensitive detection of carcinoembryonic antigen (CEA) using a homemade 3D printing device. The CeO2/CdS heterostructure with matched band structure is prepared to construct the dual-photoelectrodes to improve the PEC response of CeO2. In particular, as the photoactive nanomaterial, the CeO2 also plays the role of peroxidase mimetic nanozymes. Therefore, the catalytic performance of CeO2 with different morphologies (e.g., nano-cubes, nano-rods and nano-octahedra) have been studied, and CeO2 nano-cubes (c-CeO2) achieve the optimal catalytic activity. Upon introducing CEA, the sandwich-type immunocomplex is formed in the microplate using GOx-AuNPs-labeled second antibody as detection antibody. As a result, H2O2 can be produced from the catalytic oxidization of glucose substrate by GOx, which is further catalyzed by CeO2 to form •OH, thus in situ etching CdS and decreasing the photocurrents. The self-calibration is achieved by the dual-channel photoelectrodes on the homemade 3D printing device to obtain the photocurrents ratio, thus effectively normalizing the fluctuations of external factors to enhance the accuracy. This integrated biosensor with a detection limit as low as 0.057 ng mL-1 provides a promising way for ultrasensitive immunoassay in clinic application in complex environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Chemistry and Chemical Engineering, Key Laboratory of Shandong Provincial Universities for Functional Molecules and Materials, Qingdao University, Qingdao, 266000, PR China.
- College of Chemistry and Chemical Engineering, Key Laboratory of Shandong Provincial Universities for Functional Molecules and Materials, Qingdao University, Qingdao, 266000, PR China. Electronic address: bisai11@126.co…
Förderung
- Qingdao Postdoctoral Science Foundation
- Taishan Scholar Foundation of Shandong Province
- Qingdao University of Science and Technology
- National Natural Science Foundation of China
- Department of Science and Technology of Shandong Province
Zitieren
APA
Lv, S., Zhou, Y., Wang, H., Kong, L., & Bi, S. (2024). Spatial-resolved and self-calibrated 3D-printed photoelectrochemical biosensor engineered by multifunctional CeO2/CdS heterostructure for immunoassay. Biosensors and Bioelectronics, 262, 116553. https://doi.org/10.1016/j.bios.2024.116553
Vancouver
Lv S, Zhou Y, Wang H, Kong L, Bi S. Spatial-resolved and self-calibrated 3D-printed photoelectrochemical biosensor engineered by multifunctional CeO2/CdS heterostructure for immunoassay. Biosensors and Bioelectronics. 2024;262:116553. doi:10.1016/j.bios.2024.116553
BibTeX
@article{Lv2024,
author = {Lv, Shuzhen and Zhou, Yuting and Wang, Huijie and Kong, Lingyi and Bi, Sai},
title = {Spatial-resolved and self-calibrated 3D-printed photoelectrochemical biosensor engineered by multifunctional CeO2/CdS heterostructure for immunoassay},
journal = {Biosensors and Bioelectronics},
year = {2024},
volume = {262},
pages = {116553},
doi = {10.1016/j.bios.2024.116553}
}
EUVIMED