Assembly of ligation chain reaction and DNA triangular prism for miRNA diagnostics
Biosensors and Bioelectronics · 2024
DOI: 10.1016/j.bios.2024.116551 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Hua Chai und 3 weiteren Autor:innen. Beteiligte Einrichtung: Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, China. Hauptthemen laut MEDLINE: MicroRNAs, Biosensing Techniques, DNA, Nanostructures. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
Controllable assembly of DNA nanostructure provides a powerful way for quantitative analysis of various targets including nucleic acid molecules. In this study, we have designed detachable DNA nanostructures at electrochemical sensing interface and constructed a ligation chain reaction (LCR) strategy for amplified detection of miRNA. A three-dimensional DNA triangular prism nanostructure is fabricated to provide suitable molecule recognition environment, which can be further regenerated for additional tests via convenient pH adjustment. Target triggered LCR is highly efficient and specific towards target miRNA. Under optimal experimental conditions, this approach enables ultrasensitive exploration in a wide linear range with a single-base resolution. Moreover, it shows excellent performances for the analysis of cell samples and clinical serum samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, China.
- Affiliated Hospital of Nantong University, Nantong, 226001, China. Electronic address: 834634366@qq.com.
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, China. Electronic address: miaopeng@sibet.ac.cn.
Zitieren
APA
Chai, H., Shi, J., Zhuang, Y., & Miao, P. (2024). Assembly of ligation chain reaction and DNA triangular prism for miRNA diagnostics. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116551
Vancouver
Chai H, Shi J, Zhuang Y, Miao P. Assembly of ligation chain reaction and DNA triangular prism for miRNA diagnostics. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116551
BibTeX
@article{Chai2024,
author = {Chai, Hua and Shi, Jiayue and Zhuang, Yuan and Miao, Peng},
title = {Assembly of ligation chain reaction and DNA triangular prism for miRNA diagnostics},
journal = {Biosensors and Bioelectronics},
year = {2024},
doi = {10.1016/j.bios.2024.116551}
}
EUVIMED