Iodide based electrochemical gold quantification method for lateral flow assays
Biosensors and Bioelectronics · 2024-10 · 262 · 116524
DOI: 10.1016/j.bios.2024.116524 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-10. Verfasst von Yves Blickenstorfer und 11 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Biosensors and Bioelectronics, Institute of Biomedical Engineering, ETH Zurich, Zurich, Switzerland; Hemetron Ag, Thalwil, Switzerland. Hauptthemen laut MEDLINE: Gold, Biosensing Techniques, Electrochemical Techniques, Metal Nanoparticles. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Botnar Research Centre for Child Health.
Abstract (Originalsprache)
The lateral flow assay (LFA) is an ideal technology for at-home medical diagnostic tests due to its ease of use, cost-effectiveness, and rapid results. Despite these advantages, only few LFAs, such as the pregnancy and COVID-19 tests, have been translated from the laboratory to the homes of patients. To date, the medical applicability of LFAs is limited by the fact that they only provide yes/no answers unless combined with optical readers that are too expensive for at-home applications. Furthermore, LFAs are unable to compete with the state-of-the-art technologies in centralized laboratories in terms of detection limits. To address those shortcomings, we have developed an electrochemical readout procedure to enable quantitative and sensitive LFAs. This technique is based on a voltage-triggered in-situ dissolution of gold nanoparticles, the conventional label used to visualize target-specific signals on the test line in LFAs. Following the dissolution, the amount of gold is measured by electroplating onto an electrode and subsequent electrochemical quantification of the deposited gold. The measured current has a low noise, which achieves superior detection limits compared to optical techniques where background light scattering is limiting the readout performance. In addition, the hardware for the readout was developed to demonstrate translatability towards low-cost electronics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Laboratory of Biosensors and Bioelectronics, Institute of Biomedical Engineering, ETH Zurich, Zurich, Switzerland; Hemetron Ag, Thalwil, Switzerland.
- Division of Internal Medicine, University Hospital Basel, Basel, Switzerland; Department of Clinical Research, University Hospital Basel, University of Basel, Basel, Switzerland.
- Laboratory of Biosensors and Bioelectronics, Institute of Biomedical Engineering, ETH Zurich, Zurich, Switzerland.
- Hemetron Ag, Thalwil, Switzerland.
- Clinical Virology, Laboratory Medicine, University Hospital Basel, Basel, Switzerland.
- Laboratory of Biosensors and Bioelectronics, Institute of Biomedical Engineering, ETH Zurich, Zurich, Switzerland. Electronic address: voros@ethz.ch.
Förderung
- Botnar Research Centre for Child Health
Zitieren
APA
Blickenstorfer, Y., Jirasko, V., Tanno, A., Dräger, S., Hoven, D., Löhle, J., Leuch, S., Mamedava, Y., Müller, S. L., Leuzinger, K., Osthoff, M., & Vörös, J. (2024). Iodide based electrochemical gold quantification method for lateral flow assays. Biosensors and Bioelectronics, 262, 116524. https://doi.org/10.1016/j.bios.2024.116524
Vancouver
Blickenstorfer Y, Jirasko V, Tanno A, Dräger S, Hoven D, Löhle J, et al. Iodide based electrochemical gold quantification method for lateral flow assays. Biosensors and Bioelectronics. 2024;262:116524. doi:10.1016/j.bios.2024.116524
BibTeX
@article{Blickenstorfer2024,
author = {Blickenstorfer, Yves and Jirasko, Vlastimil and Tanno, Alexander and Dräger, Sarah and Hoven, Darius and Löhle, Josephine and Leuch, Stephan and Mamedava, Yulya and Müller, Sereina Livia and Leuzinger, Karoline and Osthoff, Michael and Vörös, János},
title = {Iodide based electrochemical gold quantification method for lateral flow assays},
journal = {Biosensors and Bioelectronics},
year = {2024},
volume = {262},
pages = {116524},
doi = {10.1016/j.bios.2024.116524}
}
EUVIMED