EUVIMEDEUVIMED entdecken
Crossref

Split T7 switch-mediated cell-free protein synthesis system for detecting target nucleic acids

Doyeon Kim, Junhyeong Kim, Jinjoo Han, Jiye Shin, Ki Soo Park

Biosensors and Bioelectronics · 2024

DOI: 10.1016/j.bios.2024.116517 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Doyeon Kim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biological Engineering, College of Engineering, Konkuk University, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Cell-Free System, Biosensing Techniques, Protein Biosynthesis, Nucleic Acids. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Ministry of Science, ICT and Future Planning, Ministry of Food and Drug Safety, National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cell-free protein synthesis (CFPS) reactions can be used to detect nucleic acids. However, most CFPS systems rely on a toehold switch and exhibit the following critical limitations: (i) off-target signals due to leaky translation in the absence of target nucleic acids, (ii) a suboptimal detection limit of approximately 30 nM without pre-amplification, and (iii) labor-intensive screening processes due to sequence constraints for the target nucleic acids. To overcome these shortcomings, we developed a new split T7 switch-mediated CFPS system in which the split T7 promoter was applied to a three-way junction structure to selectively initiate transcription-translation only in the presence of target nucleic acids. Both fluorescence and colorimetric detection systems were constructed by employing different reporter proteins. Notably, we introduced the self-complementation of split fluorescent proteins to streamline preparation of the proposed system, enabling versatile applications. Operation of this one-pot approach under isothermal conditions enabled the detection of target nucleic acids at concentrations as low as 10 pM, representing more than a thousand times improvement over previous toehold switch-based approaches. Furthermore, the proposed system demonstrated high specificity in detecting target nucleic acids and compatibility with various reporter proteins encoded in the expression region. By eliminating issues associated with the previous toehold switch system, our split T7 switch-mediated CFPS system could become a core platform for detecting various target nucleic acids.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cell-Free SystemBiosensing TechniquesProtein BiosynthesisNucleic AcidsBacteriophage T7ColorimetryPromoter Regions, GeneticLimit of DetectionViral ProteinsHumans

Stichwörter der Autor:innen

Cell free protein synthesisIsothermal amplificationMolecular diagnosticsOne-pot systemSelf-complementing split fluorescent proteinSplit T7 switch

Substanzen

Nucleic AcidsViral Proteins

Autor:innen und Institutionen

  • Department of Biological Engineering, College of Engineering, Konkuk University, Seoul, Republic of Korea.
  • Department of Biological Engineering, College of Engineering, Konkuk University, Seoul, Republic of Korea. Electronic address: akdong486@konkuk.ac.kr.

Förderung

  • Ministry of Science, ICT and Future Planning
  • Ministry of Food and Drug Safety
  • National Research Foundation of Korea

Zitieren

APA

Kim, D., Kim, J., Han, J., Shin, J., & Park, K. S. (2024). Split T7 switch-mediated cell-free protein synthesis system for detecting target nucleic acids. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116517

Vancouver

Kim D, Kim J, Han J, Shin J, Park KS. Split T7 switch-mediated cell-free protein synthesis system for detecting target nucleic acids. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116517

BibTeX
@article{Kim2024,
  author = {Kim, Doyeon and Kim, Junhyeong and Han, Jinjoo and Shin, Jiye and Park, Ki Soo},
  title = {Split T7 switch-mediated cell-free protein synthesis system for detecting target nucleic acids},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  doi = {10.1016/j.bios.2024.116517}
}
Kostenlos starten →