EUVIMEDEUVIMED entdecken
Crossref

A 3D neuronal network read-out interface with high recording performance using a neuronal cluster patterning on a microelectrode array

Dongjo Yoon, Yoonkey Nam

Biosensors and Bioelectronics · 2024-10 · 261 · 116507

DOI: 10.1016/j.bios.2024.116507 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-10. Verfasst von Dongjo Yoon und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea. Hauptthemen laut MEDLINE: Microelectrodes, Neurons, Nerve Net. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In recent years, in vitro three-dimensional (3D) neuronal network models utilizing extracellular matrices have been advancing. To understand the network activity from these models, attempts have been made to measure activity in multiple regions simultaneously using a microelectrode array (MEA). Although there hve been many attempts to measure the activity of 3D networks using 2-dimensional (2D) MEAs, the physical coupling between the 3D network and the microelectrodes was not stable and needed to be improved. In this study, we proposed a neuronal cluster interface that improves the active channel ratio of commercial 2D MEAs, enabling reliable measurement of 3D network activity. To achieve this, neuronal clusters, which consist of a small number of neurons, were patterned on microelectrodes and used as mediators to transmit the signal between the 3D network and the microelectrodes. We confirmed that the patterned neuronal clusters enhanced the active channel ratio and SNR(signal-to-noise-ratio) about 3D network recording and stimulation for a month. Our interface was able to functionally connect with 3D networks and measure the 3D network activity without significant alternation of activity characteristics. Finally, we demonstrated that our interface can be used to analyze the differences in the dynamics of 3D and 2D networks and to construct the 3D clustered network. This method is expected to be useful for studying the functional activity of various 3D neuronal network models, offering broad applications for the use of these models.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroelectrodesNeuronsNerve NetAnimalsBiosensing TechniquesRatsAction PotentialsCells, CulturedEquipment Design

Stichwörter der Autor:innen

Cell cultureElectrophysiologyHydrogelMicroelectrode arrayNeural interfaceNeuron

Autor:innen und Institutionen

  • Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea.
  • Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea. Electronic address: ynam@kaist.ac.kr.

Förderung

  • National Research Foundation of Korea

Zitieren

APA

Yoon, D., & Nam, Y. (2024). A 3D neuronal network read-out interface with high recording performance using a neuronal cluster patterning on a microelectrode array. Biosensors and Bioelectronics, 261, 116507. https://doi.org/10.1016/j.bios.2024.116507

Vancouver

Yoon D, Nam Y. A 3D neuronal network read-out interface with high recording performance using a neuronal cluster patterning on a microelectrode array. Biosensors and Bioelectronics. 2024;261:116507. doi:10.1016/j.bios.2024.116507

BibTeX
@article{Yoon2024,
  author = {Yoon, Dongjo and Nam, Yoonkey},
  title = {A 3D neuronal network read-out interface with high recording performance using a neuronal cluster patterning on a microelectrode array},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {261},
  pages = {116507},
  doi = {10.1016/j.bios.2024.116507}
}
Kostenlos starten →