Sensitive sensing of GLA and ISL based on highly conductivity nitrogen-doped carbon synergistic dual-template molecularly imprinted ratiometric electrochemical sensor
Biosensors and Bioelectronics · 2024-09 · 259 · 116384
DOI: 10.1016/j.bios.2024.116384 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-09. Verfasst von Yanbing Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Xinjiang Phytomedicine Resource and Utilization, Ministry of Education, School of Pharmacy, Shihezi University, Shihezi 832002, PR …. Hauptthemen laut MEDLINE: Biosensing Techniques, Carbon, Electrochemical Techniques, Nitrogen. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Basic and Applied Basic Research Foundation of Guangdong Province.
Abstract (Originalsprache)
A novel ratiometric Molecularly Imprinted Electrochemical sensor for the specific marker of Glycyrrhiza glabra L. was developed in this work. To achieve simultaneous detection of two analytes on one sensor, we constructed a double template molecular imprinted electrochemical sensor with glabridin (GLA) and isoliquiritin (ISL) as templates. Further, Ferrocene/ZIF-8 (Fc/ZIF-8) composites were prepared via a one-pot solvothermal reaction and coated on the surface of a glassy carbon electrode (GCE), and the oxidation of Fc was presented as the internal reference signal. Nitrogen-doped carbon (NOC) with high conductivity was further loaded on the modified GCE. Based on theoretical exploration and computer directional simulation of density functional theory (DFT), the optimal functional monomer and the best ratio of double template molecules to functional monomer were screened. Under optimal conditions, the sensor produced electrochemical curves when exposed to a solution containing GLA and ISL. As the concentration of GLA and ISL increased, the peak current intensity of GLA and ISL (IGLA and IISL) also increased, while the peak current intensity of Fc (as a reference signal) remained relatively constant. The values of IGLA/IFc and IISL/IFc showed excellent linear relationships with GLA and ISL concentrations in the range of 0.1-160 μM and 0.5-150 μM, respectively. The detection limits were 0.052 μM and 0.27 μM (S/N = 3), respectively. Due to the imprinting effect of MIP and the existence of a reference signal, the sensor exhibited excellent selectivity and anti-interference ability and was successfully applied to the quality evaluation of Glycyrrhiza glabra L.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Xinjiang Phytomedicine Resource and Utilization, Ministry of Education, School of Pharmacy, Shihezi University, Shihezi 832002, PR China; School of Chemistry and Chemical Engineering/State Key Laborato…
- Key Laboratory of Xinjiang Phytomedicine Resource and Utilization, Ministry of Education, School of Pharmacy, Shihezi University, Shihezi 832002, PR China.
- School of Chemistry and Chemical Engineering/State Key Laboratory Incubation Base for Green Processing of Chemical Engineering, Shihezi University, Shihezi 832002, PR China. Electronic address: steven_weiz@sina.com.
- Key Laboratory of Xinjiang Phytomedicine Resource and Utilization, Ministry of Education, School of Pharmacy, Shihezi University, Shihezi 832002, PR China; Shanxi Key Laboratory of Natural Products & Chemical Biology, C…
Förderung
- Basic and Applied Basic Research Foundation of Guangdong Province
Zitieren
APA
Chen, Y., Su, X., Wu, Z., Deng, X., Zhang, Y., Zhao, Z., Wei, Z., & Sun, S. (2024). Sensitive sensing of GLA and ISL based on highly conductivity nitrogen-doped carbon synergistic dual-template molecularly imprinted ratiometric electrochemical sensor. Biosensors and Bioelectronics, 259, 116384. https://doi.org/10.1016/j.bios.2024.116384
Vancouver
Chen Y, Su X, Wu Z, Deng X, Zhang Y, Zhao Z, et al. Sensitive sensing of GLA and ISL based on highly conductivity nitrogen-doped carbon synergistic dual-template molecularly imprinted ratiometric electrochemical sensor. Biosensors and Bioelectronics. 2024;259:116384. doi:10.1016/j.bios.2024.116384
BibTeX
@article{Chen2024,
author = {Chen, Yanbing and Su, Xiao and Wu, Zhenyu and Deng, Xiling and Zhang, Yuling and Zhao, Zhihao and Wei, Zhong and Sun, Shiguo},
title = {Sensitive sensing of GLA and ISL based on highly conductivity nitrogen-doped carbon synergistic dual-template molecularly imprinted ratiometric electrochemical sensor},
journal = {Biosensors and Bioelectronics},
year = {2024},
volume = {259},
pages = {116384},
doi = {10.1016/j.bios.2024.116384}
}
EUVIMED