EUVIMEDEUVIMED entdecken
Crossref

Dual structure-switching aptamer-mediated signal amplification cascade for SARS-CoV-2 detection

Jaewoo Lim, Seong Uk Son, Jisun Ki, Sunjoo Kim, Jina Lee, Soojin Jang, Seung Beom Seo, Hyowon Jang, Taejoon Kang, Juyeon Jung, Eunjung Kim, Eun-Kyung Lim

Biosensors and Bioelectronics · 2024

DOI: 10.1016/j.bios.2024.116375 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Jaewoo Lim und 11 weiteren Autor:innen. Beteiligte Einrichtung: Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), 125 Gwahak-ro, Yuseong-gu, Daejeon, 34141, Repub…. Hauptthemen laut MEDLINE: SARS-CoV-2, Biosensing Techniques, Aptamers, Nucleotide, COVID-19. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Since the outbreak of the novel severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) at the end of 2019, the spread of the virus has posed a significant threat to public health and the global economy. This work proposed a one-step, dual-structure-switching aptamer-mediated signal amplification cascade for rapid and sensitive detection of the SARS-CoV-2 nucleocapsid protein. This system consisted of two DNA aptamers with structure-switching functionality and fuel DNA, where a cascade of strand hybridization and displacement triggered fluorescence generation and signal amplification. This aptamer-based amplification cascade required neither an amplification stage using enzymes nor pre-processing steps such as washing, viral isolation, and gene extraction. The assay could distinguish SARS-CoV-2 from other respiratory viruses and detect up to 1.0 PFU/assay of SARS-CoV-2 within 30 min at room temperature. In 35 nasopharyngeal clinical samples, the assay accurately assessed 25 positive and 10 negative clinical swab samples, which were confirmed using quantitative polymerase chain reaction. The strategy reported herein can help detect newly emerging pathogens and biomarkers of various diseases in liquid samples. In addition, the developed detection system consisting of only DNA and fluorophores can be widely integrated into liquid biopsy platforms for disease diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SARS-CoV-2Biosensing TechniquesAptamers, NucleotideCOVID-19Nucleic Acid Amplification TechniquesHumansCoronavirus Nucleocapsid ProteinsPhosphoproteinsLimit of DetectionCOVID-19 Nucleic Acid Testing

Stichwörter der Autor:innen

Coronavirus disease 2019In vitro detectionPoint-of-care testSignal amplificationStructure-switching aptamer

Substanzen

Aptamers, Nucleotidenucleocapsid phosphoprotein, SARS-CoV-2Coronavirus Nucleocapsid ProteinsPhosphoproteins

Autor:innen und Institutionen

  • Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), 125 Gwahak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea; Medical Device Development Center, Osong Medical Innovat…
  • Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), 125 Gwahak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea; Department of Nanobiotechnology, KRIBB School of Biotech…
  • Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), 125 Gwahak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • Department of Laboratory Medicine, Gyeongsang National University Changwon Hospital, Changwon, 51472, Republic of Korea.
  • Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), 125 Gwahak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea; Department of Cogno-Mechatronics Engineering, Pusan Nati…
  • Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), 125 Gwahak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea; School of Pharmacy, Sungkyunkwan University, Suwon, 1641…

Zitieren

APA

Lim, J., Son, S. U., Ki, J., Kim, S., Lee, J., Jang, S., Seo, S. B., Jang, H., Kang, T., Jung, J., Kim, E., & Lim, E. K. (2024). Dual structure-switching aptamer-mediated signal amplification cascade for SARS-CoV-2 detection. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116375

Vancouver

Lim J, Son SU, Ki J, Kim S, Lee J, Jang S, et al. Dual structure-switching aptamer-mediated signal amplification cascade for SARS-CoV-2 detection. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116375

BibTeX
@article{Lim2024,
  author = {Lim, Jaewoo and Son, Seong Uk and Ki, Jisun and Kim, Sunjoo and Lee, Jina and Jang, Soojin and Seo, Seung Beom and Jang, Hyowon and Kang, Taejoon and Jung, Juyeon and Kim, Eunjung and Lim, Eun-Kyung},
  title = {Dual structure-switching aptamer-mediated signal amplification cascade for SARS-CoV-2 detection},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  doi = {10.1016/j.bios.2024.116375}
}
Kostenlos starten →