EUVIMEDEUVIMED entdecken
Crossref

All-printed wearable biosensor based on MWCNT-iron oxide nanocomposite ink for physiological level detection of glucose in human sweat

Chandradas Shamili, Adarsh Sivan Pillai, S Saisree, Achu Chandran, Manoj Raama Varma, Surendran Kuzhichalil Peethambharan

Biosensors and Bioelectronics · 2024

DOI: 10.1016/j.bios.2024.116358 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024. Verfasst von Chandradas Shamili und 5 weiteren Autor:innen. Beteiligte Einrichtung: Materials Science and Technology Division, CSIR- National Institute for Interdisciplinary Science and Technology (CSIR-NIIST), Industrial Estate, P.O…. Hauptthemen laut MEDLINE: Biosensing Techniques, Nanotubes, Carbon, Sweat, Nanocomposites. Die Arbeit wurde bisher 60-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: Department of Science and Technology, Council of Scientific & Industrial Research, Science and Engineering Research Board.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable sensors for sweat glucose monitoring are gaining massive interest as a patient-friendly and non-invasive way to manage diabetes. The present work offers an alternative on-body method employing an all-printed flexible electrochemical sensor to quantify the amount of glucose in human sweat. The working electrode of the glucose sensor was printed using a custom-formulated ink containing multi-walled carbon nanotube (MWCNT), poly (3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOPT: PSS), and iron (II, III) oxide (Fe3O4) nanoparticles. This novel ink composition has good conductivity, enhanced catalytic activity, and excellent selectivity. The working electrode was modified using Prussian blue (PB) nanoparticles and glucose oxidase enzyme (GOx). The sensor displayed a linear chronoamperometric response to glucose from 1 μM to 400 μM, with a precise detection limit of ∼0.38 μM and an impressive sensitivity of ∼4.495 μAμM-1cm-2. The sensor stored at 4 °C exhibited excellent stability over 60 days, high selectivity, and greater reproducibility. The glucose detection via the standard addition method in human sweat samples acquired a high recovery rate of 96.0-98.6%. Examining human sweat during physical activity also attested to the biosensor's real-time viability. The results also show an impressive correlation between glucose levels obtained from a commercial blood glucose meter and sweat glucose concentrations. Remarkably, the present results outperform previously published printed glucose sensors in terms of detection range, low cost, ease of manufacturing, stability, selectivity, and wearability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesNanotubes, CarbonSweatNanocompositesWearable Electronic DevicesGlucoseGlucose OxidaseLimit of DetectionHumansInkElectrochemical TechniquesFerric CompoundsFerrocyanidesPolymersReproducibility of ResultsBridged Bicyclo Compounds, HeterocyclicPolystyrenes

Stichwörter der Autor:innen

Diabetes mellitusGlucose sensorMWCNT-Iron oxide inkScreen printedSweat sensorWearable sensor

Substanzen

Nanotubes, CarbonGlucoseGlucose OxidaseFerric CompoundsFerrocyanidesPolymersBridged Bicyclo Compounds, HeterocyclicPolystyrenesferric oxideferric ferrocyanide

Autor:innen und Institutionen

  • Materials Science and Technology Division, CSIR- National Institute for Interdisciplinary Science and Technology (CSIR-NIIST), Industrial Estate, P.O., Thiruvananthapuram, 695019, India; Academy of Scientific and Innova…
  • Materials Science and Technology Division, CSIR- National Institute for Interdisciplinary Science and Technology (CSIR-NIIST), Industrial Estate, P.O., Thiruvananthapuram, 695019, India.

Förderung

  • Department of Science and Technology
  • Council of Scientific & Industrial Research
  • Science and Engineering Research Board

Zitieren

APA

Shamili, C., Pillai, A. S., Saisree, S., Chandran, A., Varma, M. R., & Kuzhichalil Peethambharan, S. (2024). All-printed wearable biosensor based on MWCNT-iron oxide nanocomposite ink for physiological level detection of glucose in human sweat. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116358

Vancouver

Shamili C, Pillai AS, Saisree S, Chandran A, Varma MR, Kuzhichalil Peethambharan S. All-printed wearable biosensor based on MWCNT-iron oxide nanocomposite ink for physiological level detection of glucose in human sweat. Biosensors and Bioelectronics. 2024. doi:10.1016/j.bios.2024.116358

BibTeX
@article{Shamili2024,
  author = {Shamili, Chandradas and Pillai, Adarsh Sivan and Saisree, S and Chandran, Achu and Varma, Manoj Raama and Kuzhichalil Peethambharan, Surendran},
  title = {All-printed wearable biosensor based on MWCNT-iron oxide nanocomposite ink for physiological level detection of glucose in human sweat},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  doi = {10.1016/j.bios.2024.116358}
}
Kostenlos starten →